• <br /> TRANE <br /> Product Specifications <br /> OUTDOOR UNIT(a)(b) 4TWA4036A3000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner <br /> POWER CONNS.—V/PH/HZ(c) 208-230/3/60 Equipment certification program,which is based on AHRI standard <br /> 210/240. <br /> MIN.BRCH.CIR.AMPACITY 13 (b) Rated in accordance with AHRI standard 270. <br /> BR.CIR.PROT.RTG.—MAX.(AMPS) 20 (c) Calculated in accordance with Natl.Elec.Codes.Use only HACR <br /> circuit breakers or fuses. <br /> COMPRESSOR CLIMATUFF®-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on <br /> NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit <br /> ampacity and max.fuse size.The value shown is the branch circuit <br /> VOLTS/PH/HZ 208-230/3/60 selection current. <br /> R.L.AMPS(d)—L.R.AMPS 9.9—70 (a) No means no start components.Yes means quick start kit <br /> components.PTC means positive temperature coefficient starter. <br /> FACTORY INSTALLED Optional kit shown. <br /> START COMPONENTS(e) NO (f) Standard Air—Dry Coil—Outdoor <br /> (g) This value approximate.For more precise value see unit nameplate. <br /> INSULATION/SOUND BLANKET NO (h) Reference the outdoor unit ship-with literature for refrigerant piping <br /> length and lift guidelines.Reference the refrigerant piping software <br /> COMPRESSOR HEAT pub#32-3312-xx or refrigerant piping application guide SS- <br /> OUTDOOR FAN PROPELLER APG006-xx for long line sets or specialty applications(xx denotes <br /> latest revision). <br /> DIA.(IN.)—NO.USED 27.6—1 (') Trane outdoor condensing units are factory charged with the system <br /> TYPE DRIVE—NO.SPEEDS DIRECT—1 charge required for the outdoor condensing unit and 15 feet of tested <br /> connecting lines.If connecting line length exceeds 15 feet,then final <br /> CFM @ 0.0 IN.W.G.(f) 3440 refrigerant charge adjustment is necessary.Each additional foot over <br /> NO.MOTORS—HP 1—1/8 15 feet requires 0.6 ozs of refrigerant.See the Installer's Guide for <br /> full charging instructions. <br /> MOTOR SPEED R.P.M. 825 <br /> VOLTS/PH/HZ 200-230/1/60 <br /> F.L.AMPS 0.8 <br /> OUTDOOR COIL—TYPE SPINE FIN°' <br /> ROWS—F.P.I. 1-24 <br /> FACE AREA(SQ.FT.) 19.1 <br /> TUBE SIZE(IN.) 3/8 <br /> REFRIGERANT CONTROL EXPANSION VALVE <br /> REFRIGERANT <br /> LBS.—R-410A(O.D.UNIT)(g) 7 LBS.,1 OZ <br /> FACTORY SUPPLIED YES <br /> LINE SIZE—IN.O.D.GAS(h)(i) 7/8 <br /> LINE SIZE—IN.O.D.LIQ. 3/8 <br /> CHARGING SPECIFICATIONS <br /> SUBCOOLING 10°F <br /> DIMENSIONS H X W X D <br /> CRATED(IN.) 34.4 x 38.7 x 35.1 <br /> WEIGHT <br /> SHIPPING(LBS.) 240 <br /> NET(LBS.) 208 <br /> 4TWA4036A-SUB-3A-EN 3 <br /> L J <br />
The URL can be used to link to this page
Your browser does not support the video tag.