1601 Fifth Avenue,Suite 1300,Seattle,WA 98101 1206-382-0600 I kpff.com <br /> April 17, 2019 <br /> Mr. Drew Martin <br /> Associate Engineer <br /> dmartin@everettwa.gov <br /> Mr. Martin, <br /> Per your request in your 04/10/19 email, below are responses for each comment provided for the permit <br /> submittal of Kasch Park Roofing Repairs dated 03/06/19.This roofing repair project for Community Transit <br /> includes five(5) buildings: Building A(Permit No. B1903-012), Bus Wash Building(Permit No. B1903-010), <br /> Building C Canopy(Permit No. B1903-011), Fuel Island Canopy(Permit No. B1903-013),and the Vault Canopy <br /> (Permit No. B1903-014). <br /> Building A Permit No.: B1903-012 <br /> 1. City of Everett Comment: <br /> Sheet S1.0 is included with the set. Detail 5 appears to show some sort of new structural <br /> member. However,the details on this sheet appear to reference R-series drawings not included with this <br /> building submittal. Verify if Sheet S1.0 required in this set. <br /> Response: <br /> KPFF Comments: No,S1.0 is not needed for the Building A set; please remove the sheet entirely for this set. <br /> Bus Wash Building Permit No.: B1903-010 <br /> 2. No comments from City of Everett. <br /> Building C Canopy. Permit No.: B1903-011 <br /> 3. City of Everett Comment: <br /> The report states that the maximum additional load on the structural cannot exceed 1.3 psf without <br /> exceeding the weight threshold requiring structural evaluation. The report and Detail A/R3 indicate the <br /> additional weight consists of a coverboard, insulation,and single-ply roofing. See the link below for a <br /> representative product. <br /> https://www.jm.com/content/dam/im/global/en/commercial- <br /> roofing/Data%20sheets/Cover%20Boards/RS-5594%20DensDeck.pdf <br /> The coverboard alone will weigh approximately 1.3 lbs or more depending on the thickness; note that the <br /> required thickness is not specified in the drawings. The roll roofing is anticipated to weigh at least another 1 <br /> lb. The insulation material is unknown; a nominal weight is expected. It appears that the additional weight <br /> potentially exceeds the threshold and may require structural analysis. Please note the following two <br /> additional observations: <br /> a. City of Everett Comment:The report states that the roof construction, including connections to <br /> the existing building(vertical and lateral?), is structurally deficient as-is. The additional weight <br /> will increase this deficiency. <br /> <i <br />