My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 KASCH PARK RD 2020-12-31
>
Address Records
>
KASCH PARK RD
>
2300
>
2300 KASCH PARK RD 2020-12-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/31/2020 10:26:58 AM
Creation date
12/31/2020 10:25:47 AM
Metadata
Fields
Template:
Address Document
Street Name
KASCH PARK RD
Street Number
2300
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HUNTER • <br /> P A NOL S ENERGY S M( R T POLYISO <br /> TYPICAL PHYSICAL PROPERTY DATA CHART WARNINGS AND LIMITATIONS <br /> POLYISO FOAM CORE ONLY <br /> Insulation must be protected from open flame and kept dry at all times. <br /> PROPERTY TEST METHOD VALUE Install only as much insulation as can be covered the same day by <br /> Compressive Strength ASTM D 1621 Grade 1 (109 psi max) completed roof covering material.Hunter Panels will not be responsible <br /> Dimensional Stability ASTM D 2126 <0.5%linear change for specific building and roof design by others, for deficiencies in <br /> (7 days) construction or workmanship, for dangerous conditions on the job <br /> Water Absorption ASTM C 209 < 1%volume site or for improper storage and handling. Technical specifications <br /> Flame Spread* ASTM E 84 <75 shown in this literature are intended to be used as general <br /> guidelines only and are subject to change without notice. For more <br /> Smoke Developed* ASTM E 84 <450 information refer to the Storage and Handling Technical Bulletin at <br /> Service Temperature - 260° F or less www.hunterpanels.com,or refer to PIMA Technical Bulletin No. 109: <br /> Recycle Content 9%-pre-consumer Storage & Handling Recommendations for Polyiso Roof Insulation at <br /> *Meets the requirements of the IBC code.For specific Flame Spread or Smoke www.polyiso.org. <br /> Developed Ratings-please contact the Hunter Panels Technical Department <br /> FASTENING REQUIREMENTS* <br /> INSTALLATION FM 0.5" #OF FASTENERS PER 4X8 <br /> RATING THICKNESS FIELD PERIMETER CORNER <br /> Single-Ply Systems 1-75 0.5 12 16 24 <br /> 1-90 0.5 16 * -a <br /> Ballasted Single-Ply Systems <br /> "Contact your membrane manufacturer for their specific fastening requirements - <br /> Each H-Shield HD panel should be loosely laid as a cover board over either an .� <br /> existing roof system or base layers of insulation on the roof deck. Butt edges <br /> and stagger joints of adjacent panels. Install the roof covering according to the <br /> manufacturer's specifications. <br /> . °°. ' ,„.-- <br /> Mechanically Attached Single-Ply Systems <br /> Each H-Shield HD panel should be secured as a cover board over either an ___ <br /> existing roof system or base layers of insulation.Butt edges and stagger joints H-Shield HD - <br /> of adjacent panels. Install the roof covering according to the manufacturer's New Construction <br /> specifications. <br /> Fully Adhered Single-Ply <br /> Each H-Shield HD panel should be secured as a cover board over either <br /> an existing roof system or base layers of insulation. H-Shield HD may be <br /> adhered to a prepared concrete deck or subsequent layers of insulation with a 'fir - _--.., <br /> full mopping of hot steepasphalt, insulation adhesive or cold applied mastic. Butt <br /> PP� g P PP edges and stagger joints of adjacent panels.Install the roof covering according to the ",.,,.,r .-. <br /> manufacturer's specifications. H-Shield HD - ` ^ . I th,4 <br /> Built Up, Coal Tar And Modified Bitumen Systems(APP, SBS) over BUR ApplicationRetrofit �'it* 0" 4,.$w <br /> Each H-Shield HD panel should be secured as a cover board over either an existing roof system or base layers of insulation. H-Shield HD may be <br /> adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt,insulation adhesive or cold applied <br /> mastic. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. <br /> Re-Roofing Single-Ply Systems <br /> H-Shield HD provides a singular and sustainable solution in retrofit applications when existing insulation is left in place.To facilitate compliance with <br /> ASHRAE 90.1 Standards for energy efficiency, H-Shield HD can be installed in a single layer on top of intact and dry insulation after the Single-Ply <br /> membrane is removed. Butt edges and stagger the joints in accordance with good roofing practice and fasten as per manufacturer's specifications. <br /> The new Single-Ply membrane can then be installed over an insulation assembly that complies with the latest energy code requirements. <br /> HUM + E R <br /> Energy Smart Polyiso <br /> HUNTERPANELS.COM <br /> IS FRANKLIN STREET, PORTLAND, ME 04101 • 888.746.1114 • FAX: 877.775.1769 <br /> POLYMOCYANURA <br /> �OuuMM 13I) <br /> PIMPIM <br /> � ualityMark` NL- GFN <br /> 4EMSO' The Certified LTTR-value Mnrvurnc.uaensr ASSOCIATION i <br /> NEW YORK • ILLINOIS • FLORIDA • TEXAS • UTAH • PENNSYLVANIA • WASHINGTON 0417 <br />
The URL can be used to link to this page
Your browser does not support the video tag.