Laserfiche WebLink
Interior Lighting - building Area Method LTG-INT-BLD <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all F Revised Nov 2017 <br /> Project Title: Merrill Creek Synsor Building Market Ready Date 1/1/2017 <br /> Calculation 0 New Construction b Addition- 0 Addition For Building Department Use <br /> Area NOTES stand alone +existing <br /> " Spaces where <50%of Spaces where z 50%of ti Spaces where the Use <br /> luminaires are replaced luminaires are replaced is changing (C505) <br /> LPA # Standard 0 Additional Efficiency Package Option Q <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA.Type Refer to C406.3 for additional requirements. User Note <br /> Maximum Allowed Lighting WattagtoTE 9 <br /> Watts Allowed <br /> Location(plan#, Gross Interior Allowed (watts/ft2 x area) <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 NOTE 2 <br /> Office All Open office,closed offices 14304 0.66 9441 <br /> Total 14304 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts per <br /> Building Area room#) Fixture Description NOTE 3,4,5,6 Fixtures Fixture NOTE 7 Watts Proposed <br /> Open <br /> Office Office/Closed 2x4 recessed fixture 75 36 2700 <br /> Offices <br /> Office Open Office 2x2 recessed fixture 18 18 324 <br /> Office Open Office 6"can 20 17 340 <br /> Office Open Office 1x8 linear 18 40 720 <br /> Compliance by Building Area' <br /> I otal Allowed I otal Proposed Intenor Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Office Confirm all fixtures are reported under proposed lighting-low watts 9441 4084 COMPLIES <br /> relative to maximum allowed. <br /> Note 1-List all unique building areas per Table C405.4.2(1)that occur in the Totals 9441 4084 <br /> project scope.Select building area category from drop down menu. <br /> Note 2-Unlit Message-Enter lighting fixture information for this building area surface in Proposed Lighting Wattage table to generate <br /> Lighting <br /> Power Allowance. <br /> Note 3-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8), numberof lamps in the fixture,and ballast type(if <br /> included). <br /> For track lighting,list the length of the track(in feet)in addition to the fixture, lamp,and ballast information. 9� <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as <br /> existing in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. <br />