Laserfiche WebLink
1O PRE -STRIP WRB <br />TUCKED IN <br />BEHIND RAFTER <br />WHERE <br />FEASIBLE <br />O <br />FULLY FORMED <br />SAM SADDLE <br />O <br />SHEET -METAL <br />FLASHING <br />SAM UNDERLAYMENT <br />ROLL ONTO FASCIA <br />O <br />FASCIA <br />INSTALL SAM TURN 5" UP(:�r <br />VERTICAL WALL & LAP 4" <br />OVER ROOF UNDERLAYMENT <br />O6 INSTALL <br />UNDERLAYMENT <br />�a <br />�m <br />NOTE: DETAIL IS CONCEPT & <br />DESCRIBES DESIGN INTENT. IT DOE` OJT <br />PURPORT TO SHOW ALL CONDI�NS <br />a IJ k0�_ <br />'L' TYPE DRIP <br />EDGE METAL <br />O FLASHING <br />STALL <br />DIVER <br />1 AS f <br />FASCIA <br />Revisions <br />01.00 2020-02-19 [P.1iontl" <br />ROOF TO WALL INSTALLATION <br />PERMIT SUBMITTAL MORRISON HERSHFIELD ISOMETRIC <br />4333 fR CI ERWEO <br />SHORESIDE CONDOMINIUMS Scale <br />ROOF REHAB N.T.S. <br />YINt:EXP: <br />K. CHIN <br />STASHWCTON 2001 120TH PL SE, EVERETT WA 98208 DWG No. Version Date <br />2020.06-14 Project # 180295600 BE.502A 01.00 2020-05-08 <br />© 2018 MORRISON HERSHFIELD - These documents have been prepared specifically for this project. They are not suitable for use on other projects or in other <br />locations without approval and participation of MORRISON HERSHFIELD. <br />