Laserfiche WebLink
ABBREVIATIONS <br />AL <br />ALUMINUM <br />N <br />NORTH <br />APPROX <br />APPROXIMATE <br />NIC <br />NOT IN CONTRACT <br />ARCH <br />ARCHITECTURAL <br />NITS <br />NOT TO SCALE <br />BLDG <br />BUILDING <br />OC <br />ON CENTER <br />BOT <br />BOTTOM <br />PLY <br />PLYWOOD <br />COL <br />COLUMN <br />PT <br />PRESSURE TREATED <br />CMU <br />CONCRETE MASONRY <br />POLY <br />POLYETHYLENE <br />UNIT <br />CONIC <br />CONCRETE <br />R <br />RADIUS <br />CONT <br />CONTINUOUS <br />REF <br />REFERENCE <br />CONST <br />CONSTRUCTION <br />REINF <br />REINFORCED <br />C/W <br />COMPLETE WITH <br />REQ'D <br />REQUIRED <br />REV <br />REVERSED <br />DIA <br />DIAMETER <br />RD <br />ROOF DRAIN <br />DIM <br />DIMENSION <br />RWL <br />RAINWATER LEADER <br />DWG <br />DRAWING <br />DS <br />DOWNSPOUT <br />S <br />SOUTH <br />SAM <br />SELF ADHESIVE MEMBRANE <br />E <br />EAST <br />SEAL <br />SEALANT <br />EA <br />EACH <br />SECT <br />SECTION <br />EL <br />ELEVATION <br />SIM <br />SIMILAR <br />ELEC <br />ELECTRICAL <br />SPEC <br />SPECIFICATION <br />EIFS <br />EXTERIOR INSULATION <br />SOG <br />SLAB -ON -GRADE <br />& FINISH SYSTEM <br />SST <br />STAINLESS STEEL <br />EQ <br />EQUAL <br />STRUC <br />STRUCTURAL <br />EQUIP <br />EQUIPMENT <br />EXIST <br />EXISTING <br />T&G <br />TONGUE AND GROOVE <br />EXT <br />EXTERIOR <br />TBC <br />TO BE CONFIRMED <br />TEMP <br />TEMPERATURE <br />FC <br />FIBER CEMENT <br />TOW <br />TOP OF WALL <br />FD <br />FLOOR DRAIN <br />TYP <br />TYPICAL <br />FIN <br />FINISH <br />FRTW <br />FIRE -RETARDANT <br />UNO <br />UNLESS NOTED <br />TREATED <br />OTHERWISE <br />WOOD <br />PURR <br />FURRING OR FURRED <br />VERT <br />VERTICAL <br />VIE <br />VERIFY IN FIELD <br />GA <br />GAUGE <br />GALV <br />GALVANIZED <br />W <br />WEST <br />GWB <br />GYPSUM WALL BOARD <br />W/ <br />WITH <br />GYP <br />GYPSUM <br />W/O <br />WITHOUT <br />WRB <br />WEATHER -RESISTIVE <br />HORIZ <br />HORIZONTAL <br />BARRIER <br />INT <br />INTERIOR <br />& <br />AND <br />INSUL <br />INSULATION <br />@ <br />AT <br />If <br />NUMBERIPOUNDS <br />MAX <br />MAXIMUM <br />t <br />PLUS OR MINUS <br />MEMB <br />MEMBRANE <br />L <br />ANGLE <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />DESIGN STATEMENT <br />DESIGN ARCHITECTS STATEMENT <br />November 15, 2019 MH Ref. 1802956.00 <br />City of Everett <br />Department of Permit Services <br />3200 Cedar Street, 2nd Floor <br />Everett, WA 98201 <br />To Whom it May Concern: <br />Re: Roof Rehabilitation, Shoreside Condominiums, Everett, WA <br />In compliance with the City of Everett building permit application submission requirements and the <br />State of Washington Revised Code of Washington(RCW) 64.55, the undersigned has pm rded <br />building enclosure design documents that in my professional judgment are appropriate to satisfy the <br />requirements of ROW 64.55.005 through 64.55.090. <br />lam <br />a member of the firm MORRISON HERSHFIELD CORPORATION and I sign this letter on <br />behalf of the firm. <br />Yours very truly, <br />Morrison Hershfield Corporation <br />Ying Ken K. Chin, ARCHITECT, NCARB <br />SCOPE OF INSPECTIONS <br />In compliance with RCW 64.56.050 the following tests and inspections will be conducted by the <br />building enclosure inspector <br />(a) An independent periodic review of the building encosure during the course of <br />construction or rehabilitative construction to ascertain whether the multiunit residential building <br />has been constructed, or the rehabilitative construction has been performed, in substantial <br />compliance with the building enclosure design documents. <br />CERTIFICATION BY BUILDING ENCLOSURE INSPECTOR <br />Once the above tests and inspections are completed, the building enclosure inspector will submit a <br />signed letter to City of Everett, certifying that the building enclosure has been inspected during the <br />course of construction of the project, and that it appears to be constructed in substantial compliance <br />with the building enclosure design documents, including any revisions. <br />C:]__@�*-DETAILNUMBER <br />DRAWING NUMBER WHERE <br />DETAIL <br />IS LOCATED <br />DETAIL REFERENCE <br />DETAIL NUMBER <br />9 DETAIL TITLE <br />SCALE: <br />TITLE REFERENCE <br />BUILDING ELEVATION <br />NUMBER <br />DRAWING NUMBER WHERE <br />ELEVATION IS LOCATED <br />BUILDING ELEVATION <br />t ASSEMBLY TYPE <br />DESIGNATION <br />WALL ASSEMBLY TYPE REFERENCE <br />O <br />KEYNOTETAG <br />�.+../ DELTA REVISION <br />INDICATOR CLOUD <br />AROUND REVISION <br />REVISIONS CLOUD <br />PROJECT NORTH ARROW <br />(DIRECTION USER <br />DEFINED) <br />NORTH <br />NORTHARROW <br />LEGEND FOR DETAILS <br />• SELF ADHESNE MEMBRANE (SAM.) <br />WEATHER-RESISTNE BARRIER (W.R.B.) <br />-- EXISTING COMPONENTS <br />— — — PEDESTRIAN TRAFFIC COATING <br />HATCH PATTERN LEGEND I <br />BATT INSULATION ® CONTINUOUS SOLID <br />(EXISTING SHOWN) LUMBER <br />EXISTING CONSTRUCITON <br />INTERMITTENT SOLID <br />LUMBER <br />SCHEDULED TO REMAIN <br />CONTINUOUS SEALANT <br />PANEL WALL <br />BEAD <br />®WOOD <br />SHEATHING THICKNESS AS <br />SEALANT APPLICATION <br />SPECIFIED <br />OVER CLOSED CELL <br />GYPSUMSHEATHING <br />BACKER ROD <br />DRAWING TERMS <br />A. DEMOLISH: COMPLETELY REMOVE AND LEGALLY DISPOSE OF OFF -SITE. <br />B. NEW (ITEM): ATERM USED ON DRAWINGS TO INDICATE THAT AN ITEM IS PROVIDED <br />AS NEW WORK. <br />C. PROTECT (ITEM): A TERM USED ON DRAWINGS TO INDICATE AN ITEM REQUIRES <br />PROTECTION FROM THE WORK. <br />D. REMOVE (ITEM): A TERM USED ON DRAWINGS TO INDICATE A SPECIFIC ITEM TO BE <br />DETACHED FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSED OF OFF -SITE, <br />UNLESS INDICATED OTHERWISE TO BE REMOVED, SALVAGED, AND REINSTALLED. <br />E. REMOVE AND REINSTALL (ITEM): A TERM USED ON DRAWINGS TO INDICATE A <br />SPECIFIC ITEM TO BE DETACHED FROM EXISTING CONSTRUCTION, PREPARED FOR <br />REUSE, AND REINSTALLED BACK IN ITS EXISTING LOCATION. <br />F. RELOCATE RELOCATE (ITEM) A TERM USED IN DRAWINGS TO INDICATE AN EXISTING ITEM THAT <br />HAS BEEN REMOVED, AND TO BE REINSTALLED IN A NEW LOCATION. <br />G. SALVAGE (ITEM): CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A <br />MANNER TO PREVENT DAMAGE READY FOR REUSE. INCLUDE FASTENERS OR <br />BRACKETS NEEDED FOR REATTACHMENT IN ORIGINAL LOCATION OR ELSEWHERE. <br />H. EXISTING TO REMAIN (ITEM): ATERM USED ON DRAWINGS TO INDICATE EXISTING <br />ITEMS OF CONSTRUCTION THAT ARE NOT BE REMOVED AND THAT ARE NOT <br />OTHERWISE INDICATED TO BE REMOVED, SALVAGED, OR REMOVED AND <br />REINSTALLED. EXISTING TO REMAIN IS INDICATED BY GRAPHIC LINETYPE SYMBOL. <br />kn'rgn krxrnstrrr.<t <br />Park <br />12152 1A 5E <br />W <br />VICINITY PLAN <br />COVERSHEET <br />GENERAL PROJECT INFORMATION: <br />BE.001 ABBREVIATIONS & REFERENCE SYMBOLS LEGEND, DRAWING TERMS, NOTES <br />INDEX <br />BE.002 <br />DRAWING NOTES, ASSEMBLIES, SCOPE OF WORK <br />KEY PLANS & ELEVATIONS: <br />BE.011 <br />VICINITY PLAN <br />SE.012 <br />DETAIL REFERENCES <br />BE.013 <br />ROOF PLAN -BLDG 1 TO <br />BE.014 <br />ROOF PLAN - BLDG 9 <br />LOW SLOPE ROOF DETAILS (BUILDING 91: <br />BE.431B VENT PIPE PENETRATION <br />BE.431C PIPE/CONDUIT PENETRATION <br />BE.4B28 VEIIT 6FI .B <br />BE.43. LOW SLOPED ROOF DRAIN WITH STRAINER <br />BE.441B LOW SLOPE ROOFING PARAPET <br />BE.442A SLOPED ROOF TO ROOF PARAPET DETAIL <br />SLOPED ROOF DETAILS: <br />9E.501A ROOF ASSEMBLY INSTALLATION ISOMETRIC <br />BE.502A ROOF TO WALL INSTALLATION ISOMETRIC <br />BE.502B ROOF TO WALL ISOMETRIC - ISOMTRIC - CONTINUED <br />BE.511B SLOPED ROOF TO WALLPERPENDICULAR TO SLOPE <br />BE.5128 SLOPED ROOF TO WALL -- PARALLEL TO SLOPE <br />BEs 4A SLOPED ROOF TO INSTALLATION ISOMETRIC <br />BE.515A SLOPE ROOF TO WALL AT OUTSIDE CORNER ISOMETRIC <br />BE.521A SLOPED ROOF EDGE INSTALLATION ISOMETRIC <br />BE.532A PLUMBING STACK INSTALLATION ISOMETRIC <br />BE.633A VENT THRU SLOPED ROOF <br />BE.534A GOOSENECK VENT THRU SLOPED ROOF <br />BE.535A SKYLIGHT DETAIL <br />BE.541B SLOPED ROOF EDGE DETAIL - PARALLEL WITH SLOPE <br />BE.542B FASCIADETAIL <br />BE.544A SLOPED ROOF TO WALL SADDLE INSTALLATION ISOMETRIC <br />BE.544B SLOPED ROOF TO WALL SADDLE INSTALLATION ISOMETRIC CONTINUED <br />BE.551A ROOF VALLEY <br />BE.552A ROOF AT RIDGE VENTED <br />BE.553A ROOF AT RIDGE <br />BES54A FALL ARREST ANCHOR <br />9 <br />2D01 t20th PI SE, <br />Everett, WA 98208 . ,,..,, PI « <br />120th PI iF <br />DO NOT USE AREA BELOW I <br />coy CIF EVER POPF <br />1.00 Permit Set 2020-02-19 <br />Version Description YYYY-MM-DD <br />Stamp <br />a <br />EXP: 2020-06-14 <br />IV� <br />MORRISON HERSHFIELD <br />SHORESIDE CONDOMINIUMS <br />ROOF REHAB <br />2001 120TH PL SE, EVERETT WA 98208 <br />Project # 180295600 <br />ABBREVIATIONS & <br />REFERENCE SYMBOLS <br />LEGEND, DRAWING INDEX <br />Scale <br />N/A <br />DWG No. Version Date <br />BE.001 1 01.00 1 2020-02-19 <br />in 2018 MORRISON HERSHFIELD - These documents have been prepared specifically for this project. They are not suitable for use on other projects or in other locations without approval and participation of MORRISON HERSHFIELD. <br />