Laserfiche WebLink
ABBREVIATIONS <br />AL <br />ALUMINUM <br />N <br />NORTH <br />APPROX <br />APPROXIMATE <br />NIC <br />NOT IN CONTRACT <br />ARCH <br />ARCHITECTURAL <br />NTS <br />NOT TO SCALE <br />BLDG <br />BUILDING <br />OC <br />ON CENTER <br />BOT <br />BOTTOM <br />PLY <br />PLYWOOD <br />COL <br />COLUMN <br />PT <br />PRESSURE TREATED <br />CMU <br />CONCRETE MASONRY <br />POLY <br />POLYETHYLENE <br />UNIT <br />CONC <br />CONCRETE <br />R <br />RADIUS <br />CONT <br />CONTINUOUS <br />REF <br />REFERENCE <br />CONST <br />CONSTRUCTION <br />REINF <br />REINFORCED <br />C/W <br />COMPLETE WITH <br />REQ'D <br />REQUIRED <br />REV <br />REVERSED <br />DIA <br />DIAMETER <br />RD <br />ROOF DRAIN <br />DIM <br />DIMENSION <br />RWL <br />RAINWATER LEADER <br />DWG <br />DRAWING <br />DS <br />DOWNSPOUT <br />S <br />SOUTH <br />SAM <br />SELF ADHESIVE MEMBRANE <br />E <br />EAST <br />SEAL <br />SEALANT <br />EA <br />EACH <br />SECT <br />SECTION <br />EL <br />ELEVATION <br />SIM <br />SIMILAR <br />ELEC <br />ELECTRICAL <br />SPEC <br />SPECIFICATION <br />EIFS <br />EXTERIOR INSULATION <br />SOG <br />SLAB -ON -GRADE <br />& FINISH SYSTEM <br />SST <br />STAINLESS STEEL <br />EQ <br />EQUAL <br />STRUC <br />STRUCTURAL <br />EQUIP <br />EQUIPMENT <br />EXIST <br />EXISTING <br />T&G <br />TONGUE AND GROOVE <br />EXT <br />EXTERIOR <br />TBC <br />TO BE CONFIRMED <br />TEMP <br />TEMPERATURE <br />FC <br />FIBER CEMENT <br />TOW <br />TOP OF WALL <br />FD <br />FLOOR DRAIN <br />TYP <br />TYPICAL <br />FIN <br />FINISH <br />FRTW <br />FIRE -RETARDANT <br />UNO <br />UNLESS NOTED <br />TREATED <br />OTHERWISE <br />WOOD <br />FURR <br />FURRING OR FURRED <br />VERT <br />VERTICAL <br />VIF <br />VERIFY IN FIELD <br />GA <br />GAUGE <br />GALV <br />GALVANIZED <br />W <br />WEST <br />GWB <br />GYPSUM WALL BOARD <br />W/ <br />WITH <br />GYP <br />GYPSUM <br />W/O <br />WITHOUT <br />WRB <br />WEATHER -RESISTIVE <br />HORIZ <br />HORIZONTAL <br />BARRIER <br />INT <br />INTERIOR <br />& <br />AND <br />INSUL <br />INSULATION <br />@ <br />AT <br /># <br />NUMBER/POUNDS <br />MAX <br />MAXIMUM <br />t <br />PLUS OR MINUS <br />MEMB <br />MEMBRANE <br />L <br />ANGLE <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />DESIGN STATEMENT <br />DESIGN ARCHITECTS STATEMENT <br />November 15, 2019 MH Ref. 1802956.00 <br />City of Everett <br />Department of Permit Services <br />3200 Cedar Street, 2nd Floor <br />Everett, WA 98201 <br />To Whom B May Concern <br />Re: Roof Rehabilitation, Shoreside Condominiums, Everett, WA <br />In compliance with the City of Everett building permit application submission requirements and the <br />State of Washington Revised Code of Washington(RCW) 64.55, the undersigned has provided <br />building enclosure design documents that in my professional judgment are appropriate to satisfy the <br />requirements of RCW 64.55.005 through 64.55.090. <br />lam <br />a member of the firth MORRISON HERSHFIELD CORPORATION and I sign this letter on <br />behalf of the firm. <br />Yours very truly, <br />Morrison Hershfield Corporation <br />*'�7 <br />Ying Ken K. Chin, ARCHITECT, NCARB <br />SCOPE OF INSPECTIONS <br />In compliance with RCW 64.55.050 the following tests and inspections will be conducted by the <br />building enclosure inspector. <br />(a) An Independent periodic review of the building enclosure during the course of <br />construction or rehabilitative construction to ascertain whether the multiunit residential building <br />has been constructed, or the rehabilitative construction has been performed, in substantial <br />compliance with the building enclosure design documents. <br />CERTIFICATION BY BUILDING ENCLOSURE INSPECTOR <br />Once the above tests and inspections are completed, the building enclosure inspector will submit a <br />signed letter to City of Everett, certifying that the building enclosure has been inspected during the <br />course of construction of the project, and that it appears to be constructed in substantial compliance <br />with the building enclosure design documents, including any revisions. <br />DRAWING LEGEND <br />C 1 DETAIL NUMBER <br />BE-XXX <br />DRAWING NUMBER WHERE <br />DETAIL <br />ISLOCATED <br />DETAIL REFERENCE <br />VICINITY PLAN <br />DETAIL NUMBER <br />a <br />3 DETAIL TITLE <br />myco� <br />SCALE: <br />Q <br />TITLE REFERENCE <br />Y1S <br />r <br />BUILDING ELEVATION <br />NUMBER <br />BE-XIOt <br />DRAWING NUMBER WHERE <br />ELEVATION IS LOCATED <br />- <br />BUILDING ELEVATION <br />'+Ya nedrx4 <br />ASSEMBLY TYPE <br />�rat� a>is <br />1'— <br />ODESIGNATION <br />2001 120th PI SE, <br />WALL ASSEMBLY TYPE REFERENCE <br />Everett. WA 98ZUB <br />LO:h PI SE 140th PI iF <br />0 <br />KEYNOTE TAG <br />DELTA REVISION <br />'`--\J//��_� <br />j(AG <br />INDICATOR CLOUD <br />.. . <br />\.�./ AROUND REVISION <br />REVISIONS CLOUD <br />PROJECT NORTH ARROW <br />(DIRECTION USER <br />DEFINED) <br />NORTH <br />NORTH ARROW <br />121st St SE <br />• — SELF ADHESIVE MEMBRANE (SAM.) <br />— — — — WEATHER—RESISM BARRIER (W.R.B.) <br />EXISTING COMPONENTS <br />— — — PEDESTRIAN TRAFFIC COATING <br />HATCH PATTERN LEGEND <br />l\ / BATT INSULATION ® CONTINUOUS SOLID <br />Y (EXISTING SHOWN) LUMBER <br />INTERMITTENT SOLID <br />EXISTING CONSTRUCITON <br />LUMBER <br />- SCHEDULED TO REMAIN <br />CONTINUOUS SEALANT <br />BEAD <br />®WOOD PANEL WALL <br />SHEATHING THICKNESS AS <br />SEALANT APPLICATION <br />SPECIFIED <br />OVER CLOSED CELL <br />GYPSUM SHEATHING <br />BACKER ROD <br />I DRAWING TERMS I <br />A. DEMOLISH: COMPLETELY REMOVE AND LEGALLY DISPOSE OF OFF -SITE. <br />B. NEW (ITEM): A TERM USED ON DRAWINGS TO INDICATE THAT AN ITEM IS PROVIDED <br />AS NEW WORK. <br />C. PROTECT (ITEM): ATERM USED ON DRAWINGS TO INDICATE AN ITEM REQUIRES <br />PROTECTION FROM THE WORK. <br />D. REMOVE (ITEM): A TERM USED ON DRAWINGS TO INDICATE A SPECIFIC ITEM TO BE <br />DETACHED FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSED OF OFFSITE, <br />UNLESS INDICATED OTHERWISE TO BE REMOVED, SALVAGED, AND REINSTALLED. <br />E. REMOVE AND REINSTALL (ITEM): A TERM USED ON DRAWINGS TO INDICATE A <br />SPECIFIC ITEM TO BE DETACHED FROM EXISTING CONSTRUCTION, PREPARED FOR <br />REUSE, AND REINSTALLED BACK IN ITS EXISTING LOCATION. <br />F. RELOCATE (ITEM): A TERM USED IN DRAWINGS TO INDICATE AN EXISTING ITEM THAT <br />HAS BEEN REMOVED, AND TO BE REINSTALLED IN A NEW LOCATION. <br />G. SALVAGE (ITEM): CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A <br />MANNER TO PREVENT DAMAGE READY FOR REUSE. INCLUDE FASTENERS OR <br />BRACKETS NEEDED FOR REATTACHMENT IN ORIGINAL LOCATION OR ELSEWHERE. <br />H. EXISTING TO REMAIN (ITEM): ATERM USED ON DRAWINGS TO INDICATE EXISTING <br />ITEMS OF CONSTRUCTION THAT ARE NOT BE REMOVED AND THAT ARE NOT <br />OTHERWISE INDICATED TO BE REMOVED, SALVAGED, OR REMOVED AND <br />REINSTALLED. EXISTING TO REMAIN IS INDICATED BY GRAPHIC LINETYPE SYMBOL. <br />DRAWING INDEX <br />COVER SHEET <br />GENERAL PROJECT INFORMATION: <br />BE.001 ABBREVIATIONS & REFERENCE SYMBOLS LEGEND, DRAWING TERMS, NOTES, <br />INDEX <br />BE.002 <br />DRAWING NOTES, ASSEMBLIES, SCOPE OF WORK <br />KEY PLANS & ELEVATIONS: <br />BE.011 <br />VICINITY PLAN <br />BE.012 <br />DETAIL REFERENCES <br />BE.013 <br />ROOF PLAN -BLDG 1 TO 8 <br />BE.014 <br />ROOF PLAN - BLDG 9 <br />LOW SLOPE ROOF DETAILS (BUILDING 91: <br />BE.431B <br />VENT PIPE PENETRATION <br />BE.431C <br />PIPEJCONDUIT PENETRATION <br />BE.435A LOW SLOPED ROOF DRAIN WITH STRAINER <br />BE.441B LOW SLOPE ROOFING PARAPET <br />BE.442A SLOPED ROOF TO ROOF PARAPET DETAIL <br />SLOPED ROOF DETAILS: <br />BE.501A ROOF ASSEMBLY INSTALLATION ISOMETRIC <br />BE.502A ROOF TO WALL INSTALLATION ISOMETRIC <br />BE.502B ROOF TO WALL ISOMETRIC - ISOMTRIC - CONTINUED <br />BE.511B SLOPED ROOF TO WALL - PERPENDICULAR TO SLOPE <br />BE.512B SLOPED ROOF TO WALL - PARALLEL TO SLOPE <br />BE.514A SLOPED ROOF TO INSTALLATION ISOMETRIC <br />BE.515A SLOPE ROOF TO WALL AT OUTSIDE CORNER ISOMETRIC <br />BE.521A SLOPED ROOF EDGE INSTALLATION ISOMETRIC <br />BE.532A PLUMBING STACK INSTALLATION ISOMETRIC <br />BES33A VENT THRU SLOPED ROOF <br />BE.534A GOOSENECK VENT THRU SLOPED ROOF <br />BE.535A SKYLIGHT DETAIL <br />SE.541B SLOPED ROOF EDGE DETAIL- PARALLEL WITH SLOPE <br />BE.542B FASCIA DETAIL <br />BE.544A SLOPED ROOF TO WALL SADDLE INSTALLATION ISOMETRIC <br />BE.544B SLOPED ROOF TO WALL SADDLE INSTALLATION ISOMETRIC CONTINUED <br />BE.551A ROOFVALLEY <br />BE.552A ROOF AT RIDGE VENTED <br />BE.553A ROOF AT RIDGE <br />BE.554A FALL ARREST ANCHOR <br />I DO NOT USE AREA BELOW I <br />`f1-I�Y OF��i..-` <br />1.00 Permit Set 2020-02-19 <br />Version Description YYYY-MM-DD <br />Stamp <br />4333 REGIS ERED <br />A Hf` T <br />YIN KEN K. CHIN <br />STAT OF WASHINGTON <br />EXP: 2020-06-14 <br />IV• MORRISON HERSHFIELD <br />SHORESIDE CONDOMINIUMS <br />ROOF REHAB <br />2001 120TH PL SE, EVERETT WA 98208 <br />Project # 180295600 <br />ABBREVIATIONS & <br />REFERENCE SYMBOLS <br />LEGEND, DRAWING INDEX <br />Scale <br />N/A <br />DWG No. Version Date <br />BE.001 1 01.00 1 2020-02-19 <br />I© 2018 MORRISON HERSHFIELD - These documents have been prepared specifically for this project. They are not suitable for use on other projects or in other locations without approval and participation of MORRISON HERSHFIELD. I2018 MORRISON HERSHFIELD - These documents have been prepared specifically for this project. They are not suitable for use on other projects or in other locations without approval and participation of MORRISON HERSHFIELD. ' <br />