My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 120TH PL SE 2021-12-14
>
Address Records
>
120TH PL SE
>
2001
>
2001 120TH PL SE 2021-12-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/14/2021 8:05:07 AM
Creation date
1/4/2021 9:52:40 AM
Metadata
Fields
Template:
Address Document
Street Name
120TH PL SE
Street Number
2001
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i' r <br />ABBREVIATIONS <br />AL <br />ALUMINUM <br />N <br />NORTH <br />APPROX <br />APPROXIMATE <br />NIC <br />NOT IN CONTRACT <br />ARCH <br />ARCHITECTURAL <br />NTS <br />NOT TO SCALE <br />BLDG <br />BUILDING <br />OC <br />ON CENTER <br />BOT <br />BOTTOM <br />PLY <br />PLYWOOD <br />COL <br />COLUMN <br />PT <br />PRESSURETREATED <br />CMU <br />CONCRETE MASONRY <br />POLY <br />POLYETHYLENE <br />UNIT <br />CONIC <br />CONCRETE <br />R <br />RADIUS <br />CONT <br />CONTINUOUS <br />REF <br />REFERENCE <br />CONST <br />CONSTRUCTION <br />REINF <br />REINFORCED <br />CNy <br />COMPLETE WITH <br />REQ'D <br />REQUIRED <br />REV <br />REVERSED <br />DIA <br />DIAMETER <br />RD <br />ROOF DRAIN <br />DIM <br />DIMENSION <br />RWL <br />RAINWATER LEADER <br />DWG <br />DRAWING <br />DS <br />DOWNSPOUT <br />S <br />SOUTH <br />SAM <br />SELF ADHESIVE MEMBRANE <br />E <br />EAST <br />SEAL <br />SEALANT <br />EA <br />EACH <br />SECT <br />SECTION <br />EL <br />ELEVATION <br />SIM <br />SIMILAR <br />ELEC <br />ELECTRICAL <br />SPEC <br />SPECIFICATION <br />EIFS <br />EXTERIOR INSULATION <br />BOG <br />SLAB -ON -GRADE <br />& FINISH SYSTEM <br />SST <br />STAINLESS STEEL <br />EQ <br />EQUAL <br />STRUC <br />STRUCTURAL <br />EQUIP <br />EQUIPMENT <br />EXIST <br />EXISTING <br />T&G <br />TONGUE AND GROOVE <br />EXT <br />EXTERIOR <br />T13C <br />TO BE CONFIRMED <br />TEMP <br />TEMPERATURE <br />FC <br />FIBER CEMENT <br />TOW <br />TOP OF WALL <br />FD <br />FLOOR DRAIN <br />TYP <br />TYPICAL <br />FIN <br />FINISH <br />FRTW <br />FIRE -RETARDANT <br />UNO <br />UNLESS NOTED <br />TREATED <br />OTHERWISE <br />WOOD <br />FURR <br />FURRING OR FURRED <br />VERT <br />VERTICAL <br />VIF <br />VERIFY IN FIELD <br />GA <br />GAUGE <br />GALV <br />GALVANIZED <br />W <br />WEST <br />GWB <br />GYPSUM WALLBOARD <br />W/ <br />WITH <br />GYP <br />GYPSUM <br />W/O <br />WITHOUT <br />WRB <br />WEATHER -RESISTIVE <br />HORIZ <br />HORIZONTAL <br />BARRIER <br />INT <br />INTERIOR <br />& <br />AND <br />INSUL <br />INSULATION <br />@ <br />AT <br /># <br />NUMBER/POUNDS <br />MAX <br />MAXIMUM <br />t <br />PLUS OR MINUS <br />MEMB <br />MEMBRANE <br />L <br />ANGLE <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />DESIGN STATEMENT <br />DESIGN ARCHITECT'S STATEMENT <br />November 15, 2019 MH Ref: 1802956.00 <br />City of Everett <br />Department of Permit Services <br />3200 Cedar Street, 2md Floor <br />Everett WA 98201 <br />To Whom it May Concern: <br />Re: Roof Rehabilitation, Shoreside Condominiums, Everett, WA <br />In compliance with the City of Everett building permit application submission requirements and the <br />Slate of Washington Revised Code of Washington(RCW) 64.55, the undersigned has provided <br />building enclosure design documents that in my professional judgment are appropriate to satisfy the <br />requirements of RCW 64.55.005 through 64.55.090. <br />1 am a member of the firm MORRISON HERSHFIELD CORPORATION and I sign this letter on <br />behalf of the firm. <br />Yours very truly, <br />Morrison Hershfield Corporation <br />I•��1. J <br />ff_ <br />Ying Ken K. Chin, ARCHITECT, NCARB <br />SCOPE OF INSPECTIONS <br />In compliance with RCW 64.65.050 the following tests and inspections will be conducted by the <br />building enclosure inspector. <br />(a) An Independent periodic review of the building enclosure during the course of <br />construction or rehabilitative construction to ascertain whether the multiunit residential building <br />has been constructed, or the rehabilitative construction has been performed, in substantial <br />compliance with the building enclosure design documents. <br />CERTIFICATION BY BUILDING ENCLOSURE INSPECTOR <br />Once the above tests and inspections are completed, the building endosum inspector will submit a <br />signed letter to City of Everett, certifying that the building enclosure has been inspected during the <br />course of construction of the project, and that it appears to be constructed in substantial compliance <br />with the building enclosure design documents, including any revisions. <br />�7:71�i�11 <br />E ]_@:--DETAIL NUMBER <br />DRAWING NUMBER WHERE <br />DETAIL <br />IS LOCATED <br />DETAIL REFERENCE <br />DETAIL NUMBER <br />3 DETAIL TITLE <br />SCALE: <br />TITLE REFERENCE <br />BUILDING ELEVATION <br />NUMBER <br />DRAWING NUMBER WHERE <br />ELEVATION IS LOCATED <br />BUILDING ELEVATION <br />O�� <br />ASSEMBLY TYPE <br />DESIGNATION <br />WALL ASSEMBLY TYPE REFERENCE <br />O <br />KEYNOTETAG <br />DELTA REVISION <br />INDICATOR CLOUD <br />`..N..� <br />AROUND REVISION <br />REVISIONS CLOUD <br />PROJECT NORTH ARROW <br />(DIRECTION USER <br />NO TH <br />DEFINED) <br />NORTH ARROW <br />• SELF ADHESIVE MEMBRANE (SAM.) <br />WEATHER —RESISTIVE BARRIER (W.R.B.) <br />EXISTING COMPONENTS <br />— - — - - — PEDESTRIAN TRAFFIC COATING <br />I HATCH PATTERN LEGEND I <br />BATT INSULATION ® CONTINUOUS SOLID <br />(EXISTING SHOWN) LUMBER <br />INTERMITTENT SOLID <br />EXISTING CONSTRUCTTON <br />SCHEDULED TO REMAIN <br />LUMBER <br />CONTINUOUS SEALANT <br />PANEL WALL <br />BEAD <br />®WOOD <br />SHEATHING THICKNESS AS <br />SEALANT APPLICATION <br />SPECIFIED <br />OVER CLOSED CELL <br />GYPSUM SHEATHING <br />BACKER ROD <br />I DRAWING TERMS I <br />A. DEMOLISH: COMPLETELY REMOVE AND LEGALLY DISPOSE OF OFFSITE. <br />B. NEW (ITEM): A TERM USED ON DRAWINGS TO INDICATE THAT AN ITEM IS PROVIDED <br />AS NEW WORK. <br />C. PROTECT (ITEM): A TERM USED ON DRAWINGS TO INDICATE AN ITEM REQUIRES <br />PROTECTION FROM THE WORK <br />D. REMOVE (ITEM): A TERM USED ON DRAWINGS TO INDICATE A SPECIFIC ITEM TO BE <br />DETACHED FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSED OF OFFSITE, <br />UNLESS INDICATED OTHERWISE TO BE REMOVED, SALVAGED, AND REINSTALLED. <br />E. REMOVE AND REINSTALL (ITEM): ATERM USED ON DRAWINGS TO INDICATE A <br />SPECIFIC ITEM TO BE DETACHED FROM EXISTING CONSTRUCTION, PREPARED FOR <br />REUSE, AND REINSTALLED BACK IN ITS EXISTING LOCATION. <br />F. RELOCATE (ITEM): A TERM USED IN DRAWINGS TO INDICATE AN EXISTING ITEM THAT <br />HAS BEEN REMOVED, AND TO BE REINSTALLED IN A NEW LOCATION. <br />G. SALVAGE (ITEM): CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A <br />MANNER TO PREVENT DAMAGE READY FOR REUSE. INCLUDE FASTENERS OR <br />BRACKETS NEEDED FOR REATTACHMENT IN ORIGINAL LOCATION OR ELSEWHERE. <br />H. EXISTING To <br />To REMAIN (ITEM): ATERM USED ON DRAWINGS TO INDICATE EXISTING <br />ITEMS OF CONSTRUCTION THAT ARE NOT BE REMOVED AND THAT ARE NOT <br />OTHERWISE INDICATED TO BE REMOVED, SALVAGED, OR REMOVED AND <br />REINSTALLED. EXISTING TO REMAIN IS INDICATED BY GRAPHIC LINETYPE SYMBOL. <br />I.L. <br />VICINITY PLAN <br />O <br />2001 120th PI SE, <br />Everett, WA 98Z08 201 r; <br />DRAWING IN <br />COVERSHEET <br />GENERAL PROJECT INFORMATION: <br />BE.001 ABBREVIATIONS & REFERENCE SYMBOLS LEGEND, DRAWING TERMS, NOTES <br />INDEX <br />BE.002 <br />DRAWING NOTES, ASSEMBLIES, SCOPE OF WORK <br />KEY PLANS & ELEVATIONS: <br />BE.011 <br />VICINITYPLAN <br />BE.012 <br />DETAIL REFERENCES <br />BE.013 <br />ROOF PN - BLDG 1 TO 8 <br />SE.014 <br />ROOF PLAN: BLDG 9 <br />LOW SLOPE ROOF DETAILS (BUILDING 91: <br />BEA31 B VENT PIPE PENETRATION <br />BE.431C PIPE/CONDUIT PENETRATION <br />BE.48iB VElIT 6kiRB <br />BE.435A LOW SLOPED ROOF DRAIN WITH STRAINER <br />BE.441 B LOW SLOPE ROOFING PARAPET <br />BE.442A SLOPED ROOF TO ROOF PARAPET DETAIL <br />SLOPED ROOF DETAILS: <br />BE.501A ROOF ASSEMBLY INSTALLATION ISOMETRIC <br />BE.502A ROOF TO WALL INSTALLATION ISOMETRIC <br />BE.5028 <br />ROOF TO WALL ISOMETRIC - ISOMTRIC - CONTINUED <br />BE.51le SLOPED ROOF TO WALL- PERPENDICULAR TO SLOPE <br />BE.512B SLOPED ROOF TO WALL - PARALLEL TO SLOPE <br />BE.514A SLOPED ROOF TO INSTALLATION ISOMETRIC <br />BE.515A SLOPE ROOF TO WALL AT OUTSIDE CORNER ISOMETRIC <br />BE.521A SLOPED ROOF EDGE INSTALLATION ISOMETRIC <br />BE.532A PLUMBING STACK INSTALLATION ISOMETRIC <br />BE.533A VENT THRU SLOPED ROOF <br />SE.534A GOOSENECK VENT THRU SLOPED ROOF <br />BE.535A SKYLIGHT DETAIL <br />BE.541B SLOPED ROOF EDGE DETAIL- PARALLEL WITH SLOPE <br />BE.542B FASCIADETAIL <br />BE.544A SLOPED ROOF TO WALL SADDLE INSTALLATION ISOMETRIC <br />SE.544B SLOPED ROOF TO WALL SADDLE INSTALLATION ISOMETRIC CONTINUED <br />BE.551A ROOFVALLEY <br />BE.552A ROOF AT RIDGE VENTED - <br />BE.553A ROOF AT RIDGE <br />SE.554A FALL ARREST ANCHOR <br />DO NOT USE AREA BELOW I <br />Gig <br />RP11'r- <br />1.00 Permit Set 2020-02-19 <br />Version Description YYYY-MM-DD <br />Stamp <br />4333 REGI ERED <br />H T <br />r <br />M <br />X:00-06-14 <br />IV• <br />MORRISON HERSi-I FIELD <br />SHORESIDE CONDOMINIUMS <br />ROOF REHAB <br />2001 120TH PL SE, EVERETT WA 98208 <br />Project # 180295600 <br />ABBREVIATIONS & <br />REFERENCE SYMBOLS <br />LEGEND, DRAWING INDEX <br />Scale <br />N/A <br />DWG No. Version Date <br />BE.001 1 01.00 1 2020-02-19 <br />I© 2018 MORRISON HERSHFIELD - These documents have been prepared specifically for this project. They are not suitable for use on other projects or in other locations without approval and participation of MORRISON HERSHFIELD2018 MORRISON HERSHFIELD - These documents have been prepared specifically for this project. They are not suitable for use on other projects or in other locations without approval and participation of MORRISON HERSHFIELD. <br />
The URL can be used to link to this page
Your browser does not support the video tag.