R <br /> REINFORCING PLAN NOTES ��"'� � � � <br /> PD <br /> Reinforcing and Post Tension Plan Notes: Ame�'��P�°pe�Yoe�e'°Pme�t,'�°. <br /> 110110th Avenue NE suite 550 <br /> Bellevue,WA 98004 <br /> 1. For structural design notes, see sheet S0.02 thru S0.06. <br /> y <br /> 1 2 3 4 5 6 2. Architectural backgrounds are shown for reference only. �coNsu�TANr�s�ocoANonooREss� <br /> The dimensions shown apply to structural elements only. <br /> 7 For dimensions not shown, see architect of record submittal. � <br /> � � � � � � <br /> �� -; ,. ; ,, � � n ; .� �- <br /> 3. Contractor shall field verify existing structural conditions. If any 201 N. Maple Grove Ste. 100 ' " , <br /> 15�-�° 30� -o° 19�-6° � 28� -s° �s�-3° 2$' -�" , discre ancies are found, contractor shall contact the Architect BOtSE IDAHO 83704 <br /> p Phone(208) 342-7168 <br /> and Structural Engineer before performing alteration work. �E�oB# �sa�s�.00 <br /> I ALL STRUCTURAL DETAI USED ON THIS <br /> I I I ! I I � /-� `� E G NEER N�G 0 FIDAHO� E�RE-USE OF <br /> � 4. F�r C'��umn `SC'he`.'u�e `See Sheet 54.�`-. ANYDETAILSANDCONCEPTSISNOT . <br /> I ACCEPTABLE WITHOUT WRITiEN CONSENT <br /> I OF LOCHSA ENGINEERING OF IOAHO. <br /> A � � � � � � _ 5. For bottom reinforcing, East - West reinforcing shall be bottom most , <br /> a- >� a - _ a _ - a � a _ _ - ° - - - unless noted otherwise. <br /> � � _ P M H FN <br /> i i i i i � <br /> ! � 6. For top reinforcing, North - South reinforcing shall be top most unless o �P�� °F ASH��'G N <br /> 12-#5x6�-o�� � I ' noted otherwise. For concrete slabs reinforced with mild reinforcing � � <br /> � AT 6��oc. only, provide 2" clear to top most and bottom most reinforcing uno. '� <br /> �. EACH WAY I �" � . <br /> i � For post-tensioned concrete slabs reinforced with mild reinforcing and . <br /> ' ' � ' ' I � post tensioning tendons, provide 2" clear to top most reinforcing and `�'�9� 548} � � <br /> i I 2 1/8 clear to bottom most reinforcing. �TF RAL EN \�� <br /> I ( I I I I SS�ONAL ENG <br /> g - -- - - - �- - - - - - - - - - - - -- - - - - - - - _ _ _ - - - - - - - � - - - - - 7. For typical reinforcing details see S5.03 and S5.04. 03-��.-o�o��zoz <br /> , - � - - - -� - - - - � - - � - � <br /> � � � � � I For typical post-tensioning details see S5.06 thru S5.08. <br /> e <br /> � COPYRIGHT�2005, ALL RIGHTS RESERVED ' <br /> 8. � Denotes opening in slab. For reinforcing around <br /> ' ' ; ' ' i openings at slabs reinforced with mild reinforcing only SUBMITTAL/REVISIONS <br /> see 6/S5.04 and at post-tensioned slabs see 4/S5.07 # DATE DESCRIPTION <br /> � � � � <br /> I � unless noted otherwise on plans. � 03/28/18 ADDENDA#1 <br /> � #5 AT 10°OC. EACH WAY � � I 9. All bars between columns are centered on grids, unless noted <br /> � � otherwise. <br /> N I I I I I I <br /> � 0 10. For reinforcing layout at columns see2/S5.04. For additional <br /> I � information at mild reinforced slabs see 1 /S5.04, and at post- <br /> ' ' ' ' Q �, tensioned slabs see 2/S5.08 and 3/S5.08 <br /> I �, Q " <br /> � � � � � � N o 11. In addition to all reinforcing shown on 3rd floor slab top and bottom <br /> � � o reinforcing plans, see sheet S1 .11A and S1.11 B for additional <br /> I � o <br /> i �B , , , , M Q reinforcing requirements at shear wall holdown anchors. <br /> I <br /> C _ _ _ - _ _- _ - _ _ - _ - _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _- _ _ _ _- _ _ _ _ _ � _ _ _ __ _ -_ _ _- _ _ - � _ - _ _ - 12. • � � • Denotesslabreinforcingtransitionedges. . . � <br /> � - I. i. i - - �_ - - - <br /> � , � 13. All P-T tendons shall be 1/2" in diameter, 7 wire strands, <br /> ' � � � ' I ' unbonded (sheathed) and shall be in conformance to ASTM A416. <br /> I <br /> � � � � , � � ' 14. Fe=###k Denotes effective force for continuous banded <br /> - post tensioned tendons (kips) after losses. <br /> _ _ _ � I , <br /> � � _ � � I 15. Fe=###k/ft Denotes effective force for distributed post tensioned <br /> � � #sX32�-o°AT 36°oc. _,,�,___ _ , � , tendons (kips/ft) after losses. }; <br /> � � ADDED BARS -,� -- - � <br /> °� � - '' ` - 16. �--+-� X" indicates dimension in inches from bottom of slab, . - <br /> � � � �-� � � � I ' " excluding drop caps and beam, to center of gravity of "� � <br /> '�- - � post-tensioned strands. See details on sheets S5.51 thru � <br /> , "�'` , � ��' , , � i S5.53 for additional data. N <br /> I � <br /> #5 AT 8"OC. EACH WAY I M <br /> , 17. Distributed tendon spacing shall not exceed 48 oc. (n <br /> I W � <br /> � � 18. Added tendon profiles shall match main tendon profile, uno. � <br /> � � � � � � � <br /> . <br /> ��D - - - - - a - - - - _ - - - -- - - - - - - - - - - - - - - - - - - - - - -� - - - - - - - - -- - - - - - - � - - - 19. Provide a minimum 2-post-tensioned tendons directiv over columns in � <br /> � � � I each direction. For additional information see 2�S5.08and 3/S5.08 � Z <br /> � � � � <br /> Q � <br /> , , , � 20. Coordinate all drain, blockout locations, and quantity with arch. � � � , <br /> and mechanical. Blockouts shall not interrupt PT tendons and � � z � <br /> � reinforcements, typ. For additional information see 4/S5.04, 6/S5.04 - <br /> i ' ' � 4/S5.07 ,and 7/S5.08 unless noted otherwise on plans. � Q � <br /> I � � Q <br /> � � � 21. Post installed anchors in post-tensioned slabs are not allowed � <br /> �' � unless the required embedment of the anchor is 1" or less. � <br /> N I I I O I O � � � <br /> � 22. All piping and conduit are to be hung below concrete slabs. This � � W <br /> � � � ¢ � I Q � includes but is not limited to drain lines, electrical conduits, and fire � L � <br /> _ � _ � s p r i n k l e r l i n e s. P e n e t r a t i o n s a r o u n d c o l u m n s a r e o n l y a l l o w e d � � ; <br /> - � m I � m where indicate in 4/S5.04, At penetrations near post-tension � <br /> ' ' ' � o � � o anchors, see 7�S5.08, � w � <br /> � M Q � M a 23. � Denotes post tensioned dead end. <br /> s <br /> NI - - _ - - - - - - _ - _ - - - - - _ _ _ _ __. _ _ __ _ - <br /> o, E � - , , , I 24. --�' Denotes post tensioned stressing end. Ur <br /> _ � (Tendons shown as stressed from both ends shall W <br /> � , , be pulled equally from each end. F- z , <br /> �, 12-#6x6 -0" 5-#6 i i i i I � <br /> � AT 6"OC. AT 6" OC. W ( , <br /> a o � I 25. Reinforcing between columns shall be centered and uniformly �/ ��/ Q <br /> � ' � i � i � I..I� <br /> � � � distributed between columns. <br /> � U <br /> �, 5-#6 AT 6"OC. � 7 O � <br /> ; i i i � � W L � W - <br /> w � i � , . <br /> o� _ � Z . <br /> 0 <br /> � - - - - - - - - - - - - - - - - �° U _ Q <br /> � F - - - - - - - _ _ - i _ _ � W <br /> 0 0 � � � <br /> � 4-#6x6' -0" i <br /> � AT 6" OC. � � � � � � I � O � <br /> �� 2'-0"TYP. ( � � � <br /> o � i V O <br /> � i � i i i i r <br /> �, � � J O � <br /> � Z � � � <br /> E o -�-� I- <br /> � O <br /> = U (/� <br /> � <br /> 3 p � t /►/1 , ' . <br /> m � r w <br /> p` w <br /> � � O � <br /> � <br /> 0 <br /> n. <br /> � <br /> N <br /> � 1 st FLOOR SLAB BOTTOM REINFORCING PLAN - AREA A D��BY A� <br /> � 1 <br /> �; �/8�� _ "I�-O�� SHEET NUMBER <br /> T � <br /> V � <br /> � Q <br /> � � <br /> m 1 . 02 <br /> � � <br /> U � <br /> � ' <br /> �� <br /> � O <br /> � N <br /> O <br /> �N <br /> N t") . + <br /> FULL SIZE=24x36 .� . <br /> HALF SIZE=12z18 <br />