Laserfiche WebLink
�����i <br /> REINFORCING PLAN NOTES ��J;" <br /> P� e <br /> Reinforcing and Post Tension Plan Notes: ame���n P�oPe�v oe�e�opme�t,�n�. <br /> 1101 tOth Avenue NE suite 550 <br /> Believue,WA 98004 <br /> 1. For structural design notes, see sheet S0.02 thru S0.06. - � , <br /> 2. Architectural backgrounds are shown for reference only. �coNsu�TnNT'SLOGOANDADDRESS) <br /> 1 2 3 4 5 6 7 The dimensions shown apply to structural elements only. <br /> For dimensions not shown, see architect of record submittal. ����� <br /> � ,, �, ,-, _. t. , ; ,, �,� <br /> � �5� -�° � 30� -o° � �s�-s° � Zs�-s�� �. �s�-3° � Zs�-�° � 3. Contractor shall field verify existing structural conditions. If any 201 N. Maple Grove Ste. 100 <br /> JI� " discrepancies are found, contractor shall contact the Architect BOISE IDAHO 83704 . <br /> Phone(208) 342-7168 <br /> � � � � � � ' and Stl'UCtUt"aI Ellglfl@@f b@fOf@ p@Ifi01"tllltlg aIt@t'at1011 WOfI(. LE JOB# 154191.00 <br /> ALL SIRUCTUR4L DETAI�USED ON THIS <br /> I I I I I I I 4. FOr COIUI�T�I� SChedUle See Sheet S4.OZ. P�NARECOPYRIGHT C OFLOCHSA <br /> I ENGINEERING OF IDAHO.THE RE-USE OF <br /> ANY DETAILS AND CONCEPTS IS NOT <br /> ACCEPTABLE WITHOUT WRITTEN CONSENT <br /> 12-#6x6�-O�� I OF LOCHSA ENGINEERING OF IDAHO. , ; <br /> A AT 6°oc. � � � , , , ` , _ 5. For bo tom reinforcing, East - West remforcing shall be bottom most H , <br /> t <br /> - - - - _ _ < p- ,- a . unless noted otherwise. �P M A ti <br /> , d _ a, . - , Q _ , a , . .� - d a . _ - . _ " " " � <br /> ° i a <br /> ' ' ' � 6. For top remforcmg, North - South reinforcing shall be top most unless o P�� °` S"�tic � <br /> noted otherwise. For concrete slabs reinforced with mild reinforcing � <br /> - ,�N <br /> � � � � only, provide 2" clear to top most and bottom most reinforcing uno. �� � <br /> � s-#sX2s�-s�� 6-#8x16�-o�� 6-#8x16�-o�� 6-#8x36�-s�� 6-#8x16�-o�� For post-tensioned concrete slabs reinforced with mild reinforcing and <br /> T , � post tensioning tendons, provide 2" clear to top most reinforcing and `�T�G 3548� � � <br /> EQ. EQ. EQ. EQ. EQ. 2 1/$ clear to bottom most reinforcing. �,� RA� EN a� <br /> �sS�ONAI ENG� <br /> 9-#8x29�-s° s-#sXao�-s" - 8-#8x36�-s° 9-#8x46�=a° 7. For t ical reinforcin details see S5.03 and S5.04. 03-29-1 � <br /> B - - - - - - - - - - - - _ - - - - - yp g EXP.01/07/202 <br /> -" � <br /> � For typical post-tensioning details see S5.06 thru S5.08. , : <br /> 0 0 0 0 0 0 � � _ COPYRIGHT C�2005, ALL RIGHTS RESERVED <br /> M N N N N N � M � N � 8. 0 Denotes opening in slab. For reinforcing around <br /> X O � N � � � � X � � I � <br /> � N � x � � N � N � N openings at slabs reinforced with mild reinforcing only SUBMITTAL/REVISIONS <br /> � � � * � � � � � � I � see 6/S5.04 and at post-tensioned slabs see 4I S5.07 # DATE DESCRIPTION <br /> � � , � � � � unless noted otherwise on plans. � osi2si�s ADDENDA#1 <br /> � 9. All bars between columns are centered on grids, unless noted <br /> - i i i i i � i � <br /> 't' 12-#8x29'-6" 16-#8x40'-6" � 14-#8x36'-8" I 12-#8x16'-0° � otherwise. <br /> � <br /> N ' ' ' ' ' ' 10. For reinforcing layout at columns see 2/S5.04. For additional <br /> � information at mild reinforced slabs see 1 /S5.04, and at post- <br /> � tensioned slabs see 2/S5.08 and 3/S5.08 � � <br /> 0 o q o o q q , <br /> � o io ifl � � ifl � ifl <br /> � X X X N N X x 11. In addition to all reinforcing shown on 3rd floor slab top and bottom <br /> 4 � � � * � � � � * reinforcing plans, see sheet S1.11A and S1.11 B for additional <br /> � � `° EQ. � � � ° � C° reinforcing requirements at shear wall holdown anchors. <br /> 1B � <br /> C 12-#8x46�-�0" � 10-#8x19�-o° _ _ s-#sX�2s�-o° _ _ 12. • � � • Denotes slab reinforcing transition edges. <br /> � <br /> ° � � � � 13. All P-T tendons shall be 1/2" in diameter, 7 wire strands, <br /> � � � I unbonded (sheathed) and shall be in conformance to ASTM A416. <br /> �k N � <br /> � � N 3-#8x19'-0" 6-#8x36'-8" 6-#8x16'-0" <br /> � � � 14. Fe=###k Denotes effective force for continuous banded : <br /> � X _ - - post tensioned tendons (kips) after losses. , <br /> _ � _ I <br /> ' � - � 15. Fe=###k/ft Denotes effective force for distributed post tensioned <br /> - � tendons (kips/ft) after losses. � <br /> °' � ;� 12-#8x29'-6° i 14-#8x15'-0° i = � �_ <br /> °� � - � - - ° - ' ° Q � 16. X�-� X" indicates dimension in inches from bottom of slab, � <br /> a. , , i excluding drop caps and beam, to center of gravity of � , <br /> 6-#8x36�-s° 6-#8x16�-o° post-tensioned strands. See details on sheets S5.51 thru <br /> a 10-#8x15'-0" � <br /> � S5.53 for additional data. N <br /> _ EQ EQ I 17. Distributed tendon spacing shall not exceed 48" oc. � (n � <br /> 0 <br /> , <br /> � EQ! 18. Added tendon profiles shall match main tendon profile, uno. W � ' . <br /> 12-#8x28'-6" 10-#8x15'-0" � ., 3-#8x15'-0" 9-#8x36'-8" 11-#8x46'-8" <br /> p _ _ _ _ _ _ _ _ _ _ _ - _ _ _� �_ _ _ - 19. Provide a minimum 2-post-tensioned tendons directly over columns in � <br /> 0 0 � � � each direction. Foradditional information see 2�S5.08and 3/S5.08 � z <br /> � � - - > <br /> ` Q -� O <br /> � N °° � � � d N N M N N I N 20. Coordinate all drain, blockout locations, and quantity with arch. <br /> � <br /> � N N N � � � X � � � � and mechanical. Blockouts shall not interrupt PT tendons and � � z � <br /> � � � �* �* � � �* I �* reinforcements, typ. For additional information see 4/S5.04, 6/S5.04 Q.. - <br /> � � `� � ° � � � ° ° 4/S5.07 ,and7/S5.08 unless noted otherwise on plans. � Q = <br /> i � �j � <br /> 45-#8x10'-0" � �`'r Q <br /> � � � - � i 10-#8x16�-o° , 21. Post installed anchors in post-tensioned slabs are not allowed � � <br /> � - �s-#sX2��-o�� � I unless the required embedment of the anchor is 1" or less. � � . <br /> N n 10-#8x29'-6" � i 14-#8x36'-8" ; , � i `v � J <br /> 0 22. All piping and conduit are to be hung below concrete slabs. This J Q W <br /> � � includes but is not limited to drain lines, electrical conduits, and fire � L- <br /> � <br /> - � X ' - � sprinkler lines. Penetrations around columns are only allowed � � W <br /> � � � where indicate in4/S5.04, At penetrations near post-tension � � <br /> - � `° � Ea EQ � anchors, see��S5.08. a W <br /> � <br /> � <br /> � - , � 23. � Denotes post tensioned dead end. <br /> �, E - - - -- - = 8-#8x29'-6° _ - 8-#8x27'-0" � 11-#8x36'-8" _ 14-#8x18'-0" � . <br /> o � 24. Denotes post tensioned stressing end. <br /> 0 0 _ � o � o � o � (Tendons shown as stressed from both ends shall W <br /> y � <br /> � N � N a N N N N N � N be pulled equally from each end. �- �n � � <br /> � X pp X - X X X x x x .. . <br /> EI 00 � W � W 00 00 00 00 I 00 � v <br /> � *k X �k *k *k � �k �k �k <br /> a o � � � � M � � � � � 25. Reinforcing between columns shall be centered and uniformly �/ z Q <br /> �' ' � � � distributed between columns. � U U <br /> � �0 6-#8x29'-6" 6-#8x27'-0" _ <br /> � � � <br /> � � � � <br /> � �_ � i W z W <br /> w, � � � 6-#8x36'-8" 6-#8x16'-0" O O � <br /> o �* � ' . <br /> � - - - - - - - - - - - - - - - - �° � (� � Q <br /> � F - - - - _ .a_ - _ o <br /> m 12-#6x6'-0" � I ( � � N � 1 <br /> N AT 6"OC. i 14-#6x6'-0" i i i i i � i z <br /> L.L � <br /> c� AT 6" OC. � O � Z ; <br /> � i i i i i i � i � O � � ? <br /> Z � I I I I ( I � '.� L.L r1 <br /> � Z 1..` O LJ� <br /> � <br /> a o � � <br /> ' U (/� <br /> � <br /> � <br /> m ,,, <br /> 3 a '= r <br /> o � w <br /> O � <br /> � w <br /> ; � � � <br /> a <br /> 0 <br /> d <br /> m <br /> m � <br /> � 1 st FLOOR SLAB TOP REINFORCING PLAN - AREA A D��BY A� <br /> � 1 � <br /> W 'I/S�� _ 'I�-O�� SHEET NUMBER ' � . <br /> �, ' . <br /> �� <br /> �a <br /> �� <br /> = � . o2E <br /> U� <br /> �� <br /> �� <br /> � O <br /> �- N <br /> O <br /> �N <br /> N c'� <br /> FULL SIZE=24x36 �e � <br /> HALF SIZE=12z18 <br />