Laserfiche WebLink
.��'J�ii <br /> REINFORCING PLAN NOTES ���"� <br /> PD <br /> R@IClf01'CI11g a11C� POSt T@t1SlOt1 P�aCI NOt@S: American Property Development,Inc. <br /> 110110th Avenue NE suite 550 <br /> Bellevue.WA 98004 <br /> 1. For structural design notes, see sheet S0.02 thru S0.06. <br /> 2. Architectural backgrounds are shown for reference only. ccoNsu�TaNr'SLOGOANDADDRESS) <br /> The dimensions shown apply to structural elements only. ����� <br /> 7 g 9 10 � � �2 For dimensions not shown, see architect of record submittal. <br /> �� -� � . ,, �< <� , , �� � <br /> 3. Contractor shall field verify existing structural conditions. If any 201 N. Maple Grove Ste. 100 <br /> i , i i BOISE IDAHO 83704 <br /> � 28, 7„ � 28,-9„ 28�_9�� 29� _7�� 16' -8 L discrepancies are found, contractor shall contact the Architect Phone(208) 342-7168 <br /> -�f and Structural Engineer before performing alteration work. �E�oB# �54�9�.00 <br /> � � I � I PLAN ARE COPYRIGHT LC OF LOCHSA <br /> ALL STRUCTURAL DETAI USED ON THI <br /> 4. F�r C��umn SChe,Ju�e See Shee} C�A.O�. ENGINEERINGOFIDAHOTHERE-USEOF <br /> u � .��•r ANY DETAILS AND CONCEPTS IS NOT <br /> ACCEPTABLE WITHOUT WRITTEN CONSENT <br /> � � � I � <br /> I <br /> I 12-#6x6�-O�� OF LOCHSA ENGWEERING OF IDAN . <br /> 5. For bottom reinforcing, East - West reinforcing shall be bottom most <br /> I ; AT 6��oc. unless noted otherwise. P M• H E� <br /> A �F ASH <br /> I j 6. For top reinforcing, g p <br /> North - South reinforcin shall be to most unless o�P�� '�� �, <br /> � , � � ' ' noted otherwise. For concrete slabs reinforced with mild reinforcing � :� <br /> only, provide 2" clear to top most and bottom most reinforcing uno. �� � <br /> � � v. <br /> , r_ � __� _ __ _.� � _ _ _ _ t _ _ - _ , � --- -rt.-- -- , � - -- --r - - -- � r--- - -r - - --� Forpost-tensioned concrete slabs reinforcedwith mild reinforcing and <br /> � I I I I I I I I I � post tensioning tendons, provide 2" clear to top most reinforcing and �'T,� 3�8* � <br /> � G � � <br /> � � � � � � � I I I , � 2 1/8" clear to bottom most reinforcing. °,� RA� E" �� <br /> I I � I I I I I I I I I FSS�ONAL ENG\ <br /> I I � � � 7. For t ical reinforcin details see S5.03 and S5.04. 03-��:0�0��202 <br /> r �-- - - <br /> I I � � -�- - - - - - � �_���. _-- - For typical post-tens oning details see S5.06 thru S5.08. <br /> B - - - - {- �_�sX-rr= . _� - �--- - - - - -I--9--�8����q�. _� - - - -}- - - - -I--g�r- . :�- - - -}- - - - - - --}- -s�sX - _ -- - - � - <br /> I � I I � I I N I I N � � I � � <br /> CV N <br /> � � I � � I � � I I � � I I � � I X COPYRIGHT C 2005, ALL RIGHTS RESERVED <br /> � 8, � Denotes opening in slab. For reinforcing around <br /> � I � I I � I I � I I � ( / � � ( SUBMITTAL/REVISIONS <br /> �, openings at slabs reinforced with mild reinforcing only <br /> I ( I , I I , �' I � , � � � � � see 6/S5.04 and at post-tensioned slabs see 4/S5.07 # onTE DESCRIPTION <br /> L - -� - - -- --� �-- -- - -- -J �- --- - - -- J L - --- -- --� �- - - - - - --J <br /> I -;- - � - � - � - �- unless noted otherwise on plans. � 03/28/18 ADDENDA#1 <br /> � , , � <br /> ' ' 9. All bars between columns are centered on grids, unless noted <br /> I _ <br /> I ,, otherwise. <br /> � i , I <br /> �, � 10. For reinforcing layout at columns see 2/S5.04. For additional <br /> N � , , � � ' information at mild reinforced slabs see 1 /S5.04, and at post- <br /> tensioned slabs see 2/S5.08 and 3/S5.08 <br /> I <br /> I � � � - -- - � r - - - -�- -- - - � 11. In addition to all reinforcing shown on 3rd floor slab top and bottom <br /> �- -- - -- - � � -- - - - - - � � --- - - - -� �- - -� <br /> I � � I I � I I � I � � � I I , I reinforcing plans, see sheet S1.11A and S1.11 B for additional <br /> I � � I I � I I � ( � � � I ( ( reinforcing requirements at shear wall holdown anchors. <br /> I I I I I I 15_ $ �_ � � , � <br /> � � ' I I ' I I ' I I I I 12. • �' � • Denotes slab reinforcing transition edges. <br /> C - - - - - � -s= X-�z� . _ - - - {- - - - - -I-9-�zs�-z�=�. _� - - - -I- - -f-g�r- . :�- - - -{- - - - - , - - -�- - - - - - - - -} -��s�2-c�. :� +- - - - - <br /> � � , N I I � N I I � N � � � o #sX��-o° � � ' N i 13. All P-T tendons shall be 1/2" in diameter, 7 wire strands, <br /> ( `� I I `� I I X I N I � � � unbonded (sheathed) and shall be in conformance to ASTM A416. <br /> I I I � I I I � ( I I � I I � I I k � I <br /> I � I I I I I I � �, __ � L_ � 14. Fe=###k Denotes effective force for continuous banded <br /> L- -�-- -�----- J �- - - - - 't---- - J �- -- - -'t'- - - --� - -- - -� - - - - J <br /> post tensioned tendons (kips) after losses. <br /> I <br /> 15. Fe=###k/ft Denotes effective force for distributed post tensioned <br /> I , , � ' tendons (kips/ft) after losses. }; <br /> °' � I � 16. �--� X" indicates dimension in inches from bottom of slab, � <br /> �° � I � ' ' " excluding drop caps and beam, to center of gravity of � <br /> � I , , post-tensioned strands. See details on sheets S5.51 thru � <br /> � � I� - r -- - - -- - - 1 <br /> S5.53 for additional data. N <br /> � I I M <br /> �- �- --� - - - - � � - - - --�-- - - - -� ___ ,�_._-�_. r --- -� -- - -� o- - -� `' , <br /> ( I I I � � � � 17. Distributed tendon spacing shall not exceed 48" oc. (n <br /> I � X I I <br /> � I , � I , I I , I -' � � � � 18. Added tendon profiles shall match main tendon profile, uno. W � <br /> � � � � � I <br /> � � � � I � I 9-#8x12'-0� �' � � <br /> � I I I �-#sX7�-o�� � � � I 19. Provide a minimum 2-post-tensioned tendons directiv over columns in � <br /> � - - - } -��X : - }- - - - -I-9-�s�2�=�. : + - - - - - � g��'- � _ - - - � - - - - � I � I each direction. For additional information see 2�S5.08 and 3/S5.08 > � Z <br /> � I N I I N ( I � � `° '� � <br /> � � � X � � � X � � i x � 5r#8x12'-0" i � I � I Q �- <br /> � __ o I °' I 20. Coordinate all drain, blockout locations, and quantity with arch. � z <br /> � � � � I *� I I �* I I ti I � -- - - - - - - � <br /> and mechanical. Blockouts shall not interrupt PT tendons and � � <br /> I , °' I I , °' I I , � I I � � I � <br /> �-- � - - - - - J � - - - - -fi -- - � L --- - -- - - J L- -- � -- - - J , ,. , 4/S5 07 and7/S5.8�run�e'ss noted o hetrwise on plans,04, 6/S5.04 - <br /> t � � ,,� .. � � (n <br /> � � � Q <br /> � � � �B ,_ _ 21. Post installed anchors in post-tensioned slabs are not allowed -� � <br /> -�� ` '- � �� � unless the required embedment of the anchor is 1" or less. <br /> � � � � <br /> � � <br /> � i c nduit are to be hun below concrete slabs. This W <br /> N � , 22. All pipmg and o g � � W <br /> � � � � � � �' ' � includes but is not limited to drain lines, electrical conduits, and fire s- <br /> I j �i <br /> __ , , sprinkler lines. Penetrations around columns are only allowed � � W <br /> I -_ ' <br /> � � <br /> � ' - -- where indicate in 4/S5.04. At penetrations near post-tension o W <br /> �- --C- - - -- --� � --- - - - -- � � - - -- --- - --� �--- --' - - --� �-- - - '- - � <br /> � � � � � � ; I I I I anchors, see 7/S5.08. � <br /> � � � � � � I I � I " � � I � I I � I <br /> � I I ( I ( I I I I I I 23. �- Denotes post tensioned dead end. <br /> � , <br /> N I � I I , I I , I I , I I I _ _ _ <br /> N _ _ _ _ - - - - - - - �--g��_ . : - - - --F - - - - - - - -I- -�sX�r - _ -I- - � -s=�$xrr= . _� � 24. --� Denotes post tensioned stressing end. <br /> E - - } --��X _ - - �--- - I-9-�s�2�=�. _� _ . ,� � <br /> �� � N I I � I I � I I � i i I (Tendons shown as stressed from both ends shall W <br /> ; I I ' � I I � I ( � I I � I I � I be pulled equally from each end. �' Ur <br /> �, � � �* I I *� I I � I I � I I , I W <br /> ' I � °' I I � � I I � I ( � I I ' � I 25. Reinforcing between columns shall be centered and uniformly �/ z m <br /> a � L- � - --� -- - - J �- - - -- � - - - - J �- --- - +-- - --� L- -- -+ - <br /> N -- -� � - - ---i- - - -' distributed between columns. <br /> ' � U U Q <br /> Z � <br /> D � I ' ' � I Z W <br /> W I i i i � � <br /> o O O � <br /> o � <br /> � � o V � Q <br /> o Z , <br /> � F - - - - I i i � � �, 12-#6x6'-0" � - <br /> N <br /> � I � AT 6"OC. O W <br /> � � � � H O � <br /> o� <br /> � � � � J <br /> N � � � � <br /> � I � <br /> 3� � p <br /> � Z <br /> ? o � � <br /> � <br /> � U <br /> � J � <br /> �, o � <br /> " O � <br /> m <br /> � � O W <br /> � � � � <br /> 0 <br /> E <br /> � <br /> a DRAWN BY <br /> N <br /> � 3rd FLOOR TOP SLAB REINFORCING PLAN - AREA B A <br /> > � 1/8" = 1'-0" <br /> w SHEET NUMBER <br /> � <br /> �� S1 . 0 <br /> ,N <br /> � � <br /> U� <br /> �� <br /> �� <br /> � O <br /> � N <br /> O <br /> ��N <br /> N c� <br /> FULL SIZE=24x36 <br /> HALF SIZE=12x18 <br />