Laserfiche WebLink
GARAGE T/Slab '"` <br /> CLEAR CONCRETE s,rrs <br /> SEALER, TYPICAL � � - � � � � � � �'��x� <br /> GARAGE 13'-4" ' <br /> SHEET METAL ROOFING, 24 i <br /> GAUGE MINIMUM, KYNAR ', <br /> American Property Development,Inc. <br /> FINISH, TYPICAL REFER TO STRUCTURAL 110 110th Avenue NE suite 550 <br /> _ R-30 RIGID POLYISO OR SHEET S2.03 &S2.04 ' S I <br /> BATT INSULATION STEEL TUBE STEEL FRAMING �';� 1 LAYER 8"TYPE X GWB BOTH l Be�levue,WA 98004 <br /> � � (WHITEFACE), TYPICAL. MEMBER, TYPICAL % �� CONCRETE WALL AND FLOOR/CEILING, SIDES � <br /> INSTALL WITH STICKPINS � �� SEE STRUCTURAL DRAWINGS FOR 2 LAYER$"TYPE X GWB BOTH -- - - - ----- ----- � <br /> > > - �� SIDES <br /> �� SIZES AND REINFORCING, TYPICAL � � � <br /> L BRACKET WALL �i' � �I j <br /> BRACING CONNECTED TO TRACKS TOP AND BOTTOM � � � <br /> FULL HEIGHT WALL, ,- � � � ��' � <br /> %� � PER FOOT SLOPE_ CANOPY BRACING, SEE STRUCTURAL I I <br /> TYPICAL _ - � �'T �4 -- — �, � w � <br /> -___ ____- DRAWINGS FOR SIZING AND DETAILS, i <br /> .,� B/Suspended Ceiling = TYPICAL i , <br /> 0'_0"see plans �� I <br /> r C CHANNEL LEDGER, ATTACHED TO - - - ' <br /> ,�O„ BUILDING CONCRETE WALL R-15 INSULATION il <br /> �I <br /> y <br /> ` SUSPENDED CEILING, TYPICAL ' <br /> ANGLE SUPPORT FOR ROOFING R-17.5 XPS RIGID INSULATION I i FLOOR/CEILING TYPE J � ���`� """ " `"�""" <br /> R-15 BATT INSULATION � ��� E,:i„� ��� <br /> ,� � E�����` <br /> R-10 RIGID ALL EXTERIOR s <br /> � <br /> @ n,� <br /> � <br /> �� <br /> GARAGE <br /> CONDITIONED � �� _ 3 2" HORIZONTAL Z FRAMING @ 2' HEADERS, TYPICAL '{''�' ', � <br /> 5 -2 GARAG E �°���� � �� �� <br /> S P A C E � � - � � �C � W A L L T Y P E W 1 ����� �e,:� � � .,.��:n� <br /> 7 3$" 22 ga. METAL STUDS @ 2' OC <br /> 1 HOUR 2 HOUR 2 HOUR 90 DEGREE CORNERS, TYP. <br /> 8"TYPE X GWB A9�3 " UL U404 w/ADDED INSULATION U N IT II j <br /> $"TYPE X GWB BOTH SIDES ��; ! <br /> � <br /> CONCRETE WALL <br /> �� ' COPYRIGHT C 2018, ALL RIGHTS RESERVED <br /> L" METAL, TYPICAL. ; � <br /> 1x4 TRIM, EASE BOTTOM ___ __-_.-__.---_------ __-_-_-_-_-_--�I <br /> CAULK AT - 3 5/8" 22 ga. METAL STUDS @ 2'OC <br /> - � EDGE, TYP. <br /> METAL/CONCRETE � ' SUBMITTAL�REVISIONS <br /> INTERSECTION � 3 5/8" 22 ga. METAL STUDS @ 2' OC � � 1x6 TRIM, EASE TOP EDGE , <br /> � ----- -------- <br /> TYP. `#�_DATE ', DESCRIP110N _ <br /> ALUMINUM FRAMED GARAGE WINDOW, I 1.5" RIGID INSULATION POLYISO. NOTE THAT PLATE � <br /> ' i 8/3/2018 ' ISSUE FOR CONSTRUCTION <br /> TYPICAL + HAT CHANNELS @ 2' OC + + 8" THICKNESS MAY VARY FROM '� i �10/29/2018; REVISION #1 <br /> FLOOR TO FLOOR SEE <br /> �r— -- ------ ' <br /> TYPE X WB � <br /> G <br /> � j STRUCTURALPLANS �' � i __ <br /> � , <br /> ;�, ' T/Slab �, �� <br /> �� . 24,-2°. . . <br /> - i --+-------- ___._----- <br /> 4" CHAMFER � <br /> 6" CONCRETE STEM WALL <br /> 1 ---- --- -- <br /> _- -- _._ _ _ --- <br /> CONCRETE FLOOR/CEILING � � ____ <br /> r - � � R-30 RIGID OR BATT _ _.____ _ __ <br /> � , _ <br /> � �� INSULATION, TYP. <br /> - = ;�-' ` -- -------- <br /> �� �� A9.3 ��� � � � ' SPRINKLER SYSTEM <br /> O i// I o O ENANGSER PT ALL = <br /> � � ! I � <br /> r �� !�� � � � , METAL SECURITY GRILLS � � <br /> �% �' � REFER TO DETAIL 17/A10.5 �'_�� <br /> In ri - . . T�s�ab . ' <br /> te or Non bearin wall ' � � � <br /> g . o�-o�� ,,�''` ; ' , � <br /> � S �dewalk � � Exterior Wall section � �'� � ; � � � � <br /> 3/4"=1'-0" 1 HR GA WP 1072- 1 HOUR '� � ��� ��� � ' ■ <br /> ���� �� '�� ° ' � GARAG E �.; j <br /> 3/4" = 1'-0�� — ; ,� �� '�� <br /> / _ � �I � <br /> � �� � �_ , ; � <br /> ----_ <br /> ---- <br /> -- �--- — N , <br /> _ _ �___ <br /> __- - <br /> - _---- -- � c� <br /> GARAGE CONCRETE FLOOR/CEILING GARAGE GARAGE � <br /> � <br /> M � � <br /> - < � <br /> , , <br /> , <br /> �f� � <br /> T/Slab V� <br /> . . .13-4" � � � <br /> ��� Q � z <br /> __ --- _-------- - �-+ O <br /> _ __-- __ <br /> - -- � � <br /> WATERPROOFING MEMBRANE AT CONCRETE FLOOR/CEILING 1/8" FRP PANEL W/END CAP TRACK TOP (DEFLECTION TRACK)AND SEE DETAIL 10 FOR CANOPY ' � LIGHTS J II >1 � �' <br /> UNDERSIDE OF CEILING AT ALL � BOTTOM NOTES , �j' i � �" <br /> � - � � Z <br /> NON-GARAGE SPACES �� � � � � � <br /> � 5 1/2" METAL STUD %�� Z <br /> 'I ; B/Suspended Ceiling � � �, � � <br /> 'I �� o'-o"see p�ans � 5/8"GWB ON EACH SIDE W/ ��� � <br /> -- _ � _ � Q <br /> --- - `" � <br /> ! RIGID BRACING (25 ga. STUDS OR J-CHANNEL ' � <br /> R-21 I N S U LAT I O N ______. <br /> I EQUIVALENT) @ MAXIMUM OF 8' OC. 1/8" FRP PANEL W/END CAP O <br /> �� NON-LOAD PARTITIONS SHALL RESIST � ^ � <br /> A MINIMUM OF 5 PSF TRANSVERSE 'i L•Z � <br /> '� Ij LOAD (IBC). ATTACH TO CONCRETE ; � M <br /> � W � <br /> �I WITH 16" EXPANSION ANCHORS. - I 5'-2' � � <br /> ATTacH To wa��wirH 2- No. $ GARAGE GARAGE � w <br /> ��� S-S�REWS � " FI RE CONTROL <br /> � � <br /> � w > <br /> i <br /> �, <br /> � <br /> I��� 24 HIGH CONCRETE CURB '�, o W <br /> , � , <br /> i� ' � _ i � <br /> ,I _ , � '� <br /> LOBBY I, �' � <br /> 5� — —, <br /> 1 LAYER- TYPE X GWB EACH SIDE � <br /> a <br /> � '� <br /> �i WITH 1"TYPE S DRYWALL SCREWS @ � <br /> --____. __---_ <br /> 8"OC AT VERTICAL JOINTS AND 12" OC , <br /> � AT FLOOR AND CEILING RUNNERS AND ' <br /> INTERMEDIATE STUDS CONCRETE WALL, SEE STRUCTURAL 9 TRASH ROOM WALL 1 ouPE X GWB BOTH SIDES GA WP 1072 � ' <br /> DRAWINGS FOR THICKNESS AND I <br /> REINFORCING � <br /> 3$" STEEL STUDS (22 GA.) @ 24"OC 5 1/2"22 ga. METAL STUDS @ 2' OC <br /> � I <br /> � i 18ga AT WALL HUNG CABINETS HOLLOW METAL DOOR <br /> 5 1/2" METAL STUD ' "L" METAL, TYPICAL CAULK AT ' I <br /> 5/8" GWB ON EACH SIDE W/ METAUCONCRETE INTERSECTION I I y <br /> I J-CHANNEL <br /> � REFER TO STRUCTURAL PLAN S1.01A& <br /> ' S1.01 B, S1.02A& S1.02B, S1.03A&S1.03B 1/8° FRP PANEL W/END CAP CONCRETE FLOOR SLAB V� <br /> FOR CONCRETE WALL THICKNESS & 6" HIGH CONCRETE CURB <br /> il <br /> � <br /> �' CONCRETE FASTENER @ 2'O.C. GAS REINFORCING. � CONCRETE STEM WALL-7" SEE I I, O <br /> I� OR POWDER ACTUATED ' `I i <br /> i _ STRUCTURAL U <br /> O I� <br /> � <br /> II� I�� N T/Slab � T/Slab , <br /> o�-o�� o�-o�� r �°' <br /> I'� �� CONCRETE FLOOR/CEIUNG CONCRETE FLOOR/CEILING "`I CONCRETE FLOOR/CEILING ; V J <br /> I <br /> , — <br /> , � �� <br /> � <br /> � � <br /> , <br /> : ' � <br /> .. � .. � . - � . �. � ,. F � .� � <br /> . .. _ ___ __ � t� � �,�, t�fi <br /> FOUNDATION FOOTING <br /> 1� P :� DRAWN BY � � <br /> .... <br /> T/Slab J`� <br /> . . -9'-8" �r SHEET NUMBER- - <br /> I nterior Non-bearing wall I nterior Concrete wall Metal Stud Wall on Conc. <br /> 8 9 I Exterior Wall section <br /> 3/4"=1'-0" GA WP 1072- 1 HOUR 3/4"=1'-0" - 3/4"=1'-0" Meter Rooms @ 2nd floor 20 <br /> 1/2" = 1'-0„ — I <br /> �� ■ <br />