|
: ____
<br /> 2'O.C. GAS OR POWDER �r��� ' ` '
<br /> ACTUATED I� �►.��'��� i
<br /> '-''--CONCRETE 5/8"TYPE 'X'GWB EACH SIDE I, I�
<br /> r--; �
<br /> 6" METAL FRAMED '
<br /> ; � American Property Development,Inc. ,
<br /> I i WALL CONCRETE WALL 110 110th Avenue NE suite 550
<br /> I R-21 INSULATION METAL STUDS, SEE Be��evue,WA 98004
<br /> , i STRUCTURAL SHIM SPACE — SHIM SPACE
<br /> $"TYPE X GWB �
<br /> 8°TYPE X FIBERGLASS T/Opng : T/Opng ;-� I
<br /> �� � I
<br /> A.F.F. � MAT GYPSUM 7-2 1/4� ��-a�� "!�'�
<br /> �— � SHEATHING DOOR PER DOOR SCHEDULE N �•� I
<br /> SHIM SPACE SEALANT, EACH SIDE � SEALANT, EACP SIDE
<br /> ATTACH FRAME SECURELY TO
<br /> - STRUCTURE, TYP. 22�� H.M. DOOR & FRAME H.M. DOOR& FRAME I
<br /> SEALANT, EACH SIDE FULL WEATHER FULL WEATHER
<br /> 32" STRIPPING 22" STRIPPING
<br /> ANOD.ALUM. „,.,,�„
<br /> METAL DRIP SET IN — METAL DRIP SET IN 1:�'s
<br /> 2" STOREFRONT SYSTEM WOOD FRAME �
<br /> SEALANT (PEMKO 346 C SEALANT (PEMKO 346 C � "': ��:�� �
<br /> ANOD. ALUM. TRIM TO OR D, MATCH OR D, MATCH HRDWRE "''�"��,'�
<br /> MATCH STOREFRONT HARDWARE FINISH)AT FINISH)AT HEAD ONLY � �
<br /> INSUL. GLAZING NOTE: HEAD IS SIM. HEADONLY ' ""
<br /> DQ�AtO A. F! P��t
<br /> EXTERIOR INTERIOR �e.�`t�� � �€�,��,•�
<br /> rf � �
<br /> Sto e ront Head Door amb H M Door head H M Door head
<br /> 5 9 13 17
<br /> 3"-1'-0" 3��_1'-0�� 3,�_1'-0" 3„_1'-0"
<br /> END-OF-LINE DIODE: '
<br /> FURNISHED BY SMOKE GUARD METAL FASTENER METAL FASTENER `- _
<br /> SMOKE DETECTOR: INSTALLED BY OTHERS 3 PER JAMB MIN. 3�� 2�� 3 PER JAMB MIN. 3�� 2�� COPIRIGHT QC 2ois, ALL RIGHTS RESERVED
<br /> BY OTHERS AT INITIATING DEVICE 16 16 .
<br /> • NORMALLY CLOSED 5/8"TYPE 'X'GWB EACH SIDE
<br /> 3.9v2W SEALANT EACH SIDE SEALANT EACH SIDE I SUBMITTAL�REVISIONS
<br /> DRY CONTACT ADJACENT WALL OR
<br /> —r--------
<br /> OPENS ON ALARM --�-. COLUMN # ' DATE DESCRIPTION
<br /> SHIM SPACE SHIM SPACE - a/s/zo�s � ISSUE FOR CONSTRUCTION
<br /> _ --_
<br /> STOREFRONT ALUMINUM METAL STUDS, SEE � � io/2s/2oia REVISION #t
<br /> FRAME ---
<br /> STRUCTURAL. � �
<br /> a
<br /> 120VAC AUXILIARY N. a —
<br /> CONTACT�CO , - M�I,v � a a c�i��r
<br /> BY OTHERS: 120VAC �
<br /> N.Om „ 4 a �
<br /> 120VAC 120VAC � --------------
<br /> a I
<br /> 60Hz INSULATED GLAZING DOOR PER DOOR SCHEDULE ° a a I
<br /> 2A MAX. � ° a �
<br /> HOUSING I —�
<br /> JUNCTION ATTACH FRAME SECURELY TO --
<br /> BOX � H.M. DOOR & FRAME H.M. DOOR & FRAME
<br /> STRUCT., TYP.
<br /> SEALANT-CONT. SEALANT-CONT.
<br /> ALARM CIRCUIT: SHIM, AND CAULK BOTH
<br /> BY OTHERS SIDES ��� '
<br /> 2
<br /> CMU OR CONCRETE '�, ;
<br /> i
<br /> UP TO 4 HOUSINGS CAN BE WIRED HOLLOW METAL FRAME � i
<br /> TO AN END-OF-LINE DIODE AT AN —
<br /> CONCRETE WALL
<br /> HOUSING: SIDE VIEW AUXILIARY CONTACT
<br /> N O TE: H E A D I S S I M. coNCRETE ---;---r ------- —
<br /> ROUGH OPENING WIDTHS+4 2" I
<br /> WIRING DIAGRAM -ALL ELECTRICAL BY OTHERS ROUGH OPENING HEIGHT+2 4"
<br /> INSTALL SMOKE GASKET AT ALL ',
<br /> Smoke door wirin 2 Storefront Jamb FIRERATEDDOORS, TYPICAL HM Door 'amb HM Door 'amb HM Door 'amb II'�� e
<br /> 6 10 14 18 +�
<br /> 1/2" = 1'-0�� - 3��_1'-0�� 3„_1'-0�� 3��_1'-0" "- '-0" �
<br /> �
<br /> , DOOR GUIDES WITH �
<br /> H. M. DOOR SUPPORTING HARDWARE BY A .
<br /> � COILING DOOR MFR C V
<br /> HOISTWAY — 5/8"TYPE'X'GWB EACH SIDE � ,' M
<br /> WEATHERSTRIP _ Qo �I'I �
<br /> � ELEVATOR JAMB THRESHOLD
<br /> 2-2x6 STUDS CONCRETE ' O
<br /> � � �
<br /> ALUMINUM FRAME, TYPICAL ` a � � O \ �
<br /> , /
<br /> , a Q � z
<br /> , �
<br /> +� o
<br /> DOOR OPENING DOOR PER DOOR SCHEDULE � ` � . � � � a a ` � � �
<br /> , ° � CU Z
<br /> INSUL. GLASS. PROVIDE THERMAL ATTACH FRAME SECURELY TO � a � � i
<br /> BREAK STRUCT., TYP. O 0 �� � � _
<br /> 0 CONCRETE LANDING W/1/2° , (n
<br /> � O� � Q EXPANSION JOINT, WITH SEALANT • � �
<br /> � Q
<br /> o • � (� (� '�
<br /> AUXILIARY RAIL ALUM. STOREFRONT SET IN SEALANT, _ O G a CONCRETE WALL INSTALL COILING DOOR ' O
<br /> 2 WJ ATTACHMENT PER BIDDER HOLLOW METAL FRAME " STRUCTURE � PER MANUFACTURES ' � �
<br /> DESIGN 2�� � WRITTEN INSTRUCTIONS J �
<br /> WALL THICKNESS AND � � � �
<br /> SEALANTEACHSIDE NOTE: HEAD (S SIM.
<br /> _ • CONSTRUCTION AS I � W
<br /> • SHOWN ON WALL � w
<br /> PLAN AT JAMB INSTALL SMOKE GASKET AT ALL SECTIONS AND FLOOR o W
<br /> FIRE RATED DOORS,TYPICAL � PLAN I �
<br /> Elev. smoke curtain 3 Storefront Head & Sill 7 HM Door �amb � � HM Door sill 15 Coilin Door head � g
<br /> 3"-1'-0" 3"-1'-0�� 3„_��-0�, 3,�_1'-0" 1 1/2"-1'-0"
<br /> 0 ,;
<br /> JUNCTION BOX, NO ACCESS WALL THICKNESS & I '�
<br /> 120v AC REQUIRED CONSTRUCTION AS ,
<br /> ALARM CIRCUIT MOUNTING PLATE SHOWN ON WALL i ',
<br /> REWIND MOTOR INSIDE SECTIONS & FLOOR �I
<br /> HOUSING PLAN. '
<br /> HOUSING ---- � �
<br /> CLEARANCE Q
<br /> � / --- '�<: � - �
<br /> SMOKE DETECTOR HOUSING—� � li
<br /> CEILING OR SOFFIT HOUSING DOOR O , _ ; ,
<br /> CEILING OR SOFFIT (DEPLOYED = <, '� ',
<br /> ,_ �
<br /> T } SCREEN) , p � `
<br /> 0 � � � SCREEN 3 __ „
<br /> 0 0 � ASSEMBLY o I (n
<br /> SCREEN ASSEMBLY (DEPLOYED) CEILING OR SOFFIT
<br /> CLEARANCE '
<br /> STAINLESS STEEL 1/4" STEEL 48" HIGH �
<br /> RAILS TOP OF ELEVATOR ANCHOR @ pANOS ON � � �
<br /> ELEVATOR JAMB I W
<br /> � � AUXILIARY RAIL H E A D J A M B Q
<br /> �I � � lii �
<br /> 3�� �
<br /> LANDING ELEVATION SECTION LANDING ELEVATION-READY STATE SECTION-READY STATE LANDING ELEVATION-DEPLOYED STATE SECTION-DEPLOYED STATE ,oRnvm ev
<br /> HEAD SECTION DETAIL OVERHEAD COILING
<br /> ELEVATOR JAMB DOOR �
<br /> '�------ '---__ -- --___-- -
<br /> PROTECTION ' SHEET NUMBER •
<br /> Elevator door elevation 4 Elevator smoke curtain elevation 8 Elevator smoke curtain elevation � 2 Smo e Door section � 6 Coilin Door �amb 2o i
<br /> 1/4" = 1'-0" - 1/4" = 1'-0" - 1/4" = 1'-0" - 1 1/2"=1'-0" 1 1/2"=1'-0" I ■
<br /> �_
<br />
|