Laserfiche WebLink
�,�"!���� <br /> �� � <br /> ���,��� <br /> NOTES: <br /> 1. ROOF DECK PLANTERS:AS MANUFACTURED BY ORE, INC.SALT LAKE, UT, PH. ' American Property Development,Inc. <br /> 110 110th Avenue NE suite 550 <br /> � � � (801.936.0499) OR APPROVED EQUAL. ALL PLANTERS SHALL BE ALUMINUM AND Bellevue,wA 9soo4 <br /> � � INCLUDE DRAIN FITTINGS, IRRIGATION SLEEVE AND DRIP TRAY. COLOR SHALL BE <br /> � � � CHOSEN BY OWNER OR PROJECT ARCHITECT FROM STANDARD COLORS. PROVIDE � — <br /> COLOR SAMPLE FOR APPROVAL. INSTALL PLANTERS AS SHOWN ON LANDSCAPE / <br /> � � PLANS. <br /> � 1"CHAINLOCK TREE TIES d �� � � � <br /> (2)-BVC WOOD TREE STAKES (8'HT.) SHRUB FLARE SHALL BE d d 2. INSPECT ALL PLANTERS UPON DELIVERY TO ENSURE NO DAMAGE OCCURRED DURING z <br /> � o <br /> � � <br /> 'd CLEARLY VISIBLE � d MULCH SHIPPING. W z <br /> 6 IN � MULCH IN BASIN, DEPTH PER AFTER PLANTING / � =a, <br /> : SPECIFICATIONS d d WATERING BASIN BERM �J W a� <br /> 3" ,e 3. THOROUGHLY WATER ALL PLANTS AFTER INSTALLATION, ENSURE PLANTS ARE GETTING <br /> 3"WATER RETENTION BASIN (IN SHRUB � � �n <br /> M ADEQUATE MOISTURE THOUGHOUT THE MAINTENANCE PERIOD. ` Q � �o 0 <br /> v AND GROUNDCOVER AREAS ONLI� P L A N T I N G P I T '����# � y � W �� <br /> ROOTBALL g M <br /> SHALL BE A , ��1 ,m , F_ FERTILIZER TABLETS, ` + � N LL u <br /> � J � �1 1 1 1 I I� � I I I I��1 1 1=1 1 FERTILIZER TABLETS M I N. O F T W I C E D E P T H � ' j �,� 2"-6"D E P T H C O M P L E T E L Y R E M O V E B U R L A P " , J Z o�Q <br /> � m w III III - - THE ROOTBALL 6" M IN. � F I E L D V E R I F Y R O O T B A L L S I Z E F R O M R O O T B A L L I , � � ��J <br /> � o �-111-1 -l�llk R E M O V E B U R L A P F R O M T O P 2/3 OF s (+` TOP DRESS PLANTER WITH PRIOR TO DELIVERY ON SITE � � �`"a <br /> DEPTH ; ::t = . ` ¢ REMOVE BURLAP FROM A MIN. 1"-2"L A Y E R O F N U G G E T B A R K M U L C H 1 , N w m"' <br /> Z �_T=�_ ____�� �,��JJ R O O T B A L L. �'"'� � , ; _ E-•�' - , 2 1 2" N U G T B A R K M U�C H TO ENSURE IT WI�L FIT IN � "' <br /> I-III-III , 3 ,�-�-- GE <br /> � 'I�I I I�I I I �� T I I��1 1 1,;�I 1 1= B A C K F I L L S O I L M I X ' ° ' O F /3 F R O M R O O T B A L L A F T E R (1"-2"S I Z E),T Y P. PLA NTE R 2"S I Z E), T Y P. � Z z o <br /> ROOTBALL PLACING SHRUB IN P LAN T W G , . 0 z m <br /> N ' H O L E R E M O V E C O M P L E T E L Y I F � <br /> ROOT NOTES: D I A M E T E R FIBERGLASS OR TREATED). �'°� S ECIF CA L T IONS A B S P E R � � o � <br /> BALL 1, R E M O V E T R E A T E D O R S Y N T H E T I C B U R L A P 6" 6" � <br /> WIDTH COMPLETELY. MIN. MIN REMOVE PLANTS FROM POTS O ROOF TOP SOIL MIX OR SANDY LOAM TOPSOIL o <br /> 2. INSTALL 24" DEPTH ROOT BARRIER AT THE EDGE PRIOR TO PLANTING � <br /> PLANTING PIT OF ANY PAVING WITHIN 8 FT. OF TREE TRUNK. PLANTING PIT SHALL BE BACKFILL SOIL MIX 0° <br /> S LL BE A MIN. F 3. ENSURE THE TRUNK FLARE IS VISIBLE ABOVE A MINIMUM OF TWICE <br /> 3X THE GRADE AFTER PLANTING. THE ROOT-BALL WIDTH PROVIDE LANDSCAPE FABRIC OVER INSTALL FILTER FABRIC OVER 1" LAYER <br /> R OTBALL WID . ROOF DECK,TYP. 1"OF PEA GRAVEL IN BASE OF OF PEA GRAVEL IN BASE OF PLANTER <br /> PLANTER <br /> COPYRIGHT OC 2005, ALL RIGHTS RESERVED <br /> SUBMITTAL/REVISIONS <br /> 1 TREE PLANTING & STAKING DETAIL 2 SHRUB PLANTING DETAIL (B&B OR CONT.) ROOF DECK PLANTERS . DATE DESCRIPTION <br /> 1 2/20/1 BID SET <br /> N.T.S. P-CO-LAR2-08 NTS P-CO-LAR2-05 1"= 1'-0" P-CO-LAR2-02 <br /> 20"X14"JUMBO PL CONTROLLER WIRE WITH 30 INCH LINEAR <br /> LENGTH OF COIL, WITH PLASTIC I.D. TAG AND <br /> VALVE BOX. WATERPROOF CONNECTORS. <br /> MULCH PER SPECIFICATIONS <br /> CONTINUOUS OUTER ROW OF PLANTS SPACED PVC TRUE UNION B RCV AS SPECIFIED. <br /> "X"ON CENTER AND SET BACK FROM THE TECHLINE COMBINATION TEE FINISH GRADE VALVE. BASKET FILTER AS SPECIFIED. <br /> PLANTING BED EDGE 213"X" MODEL TL075FTEE <br /> � � 2"ABOVE GRADE AT PRESSURE REGULATOR AS <br /> SHRUBS. SPECIFIED. ` ` <br /> AREA FOR SPACING ADJUSTMENT _�,. <br /> ' . , � SET BOX FLUSH z PVC UNION W/SHORT <br /> EDGE OF PLANTING BED DRIPLINE TUBING . � . , AT TURF. � NIPPLES. GRATED CAP <br /> w M <br /> , „ • m <br /> , � <br /> � ti} . M Q _ _ — — _ HUNTER PCB BUBBLER �"' <br /> � 'I�' � -I I (�I I I=� -I I I=I I I I��I I I � HUNTER HCV CHECK VALVE <br /> "�' , � p ����� � � � I �� II,� Oo <br /> 0° I 0° � STRATA ROOT SYSTEM <br /> � � . , � . I p ' o 'I � c� <br /> � . . . z . <br /> � <br /> -�- -�-- -� -�- -�- --�- -� � • ' . , S WI N G J OI NT � <br /> / \ / \ / \ 3/4" MIN. TRIPLE SWING . '� rn <br /> �—�—�—��.„�,--�- • • • � �,� V J <br /> \ / \ / \ / \X/ \X/ \ JOINT , � SCH. 80 RISER. OUTLET PIPE SAME SIZE A <br /> 7L C'r � <br /> .{...—,.�.—�..,—�.,,X�.,�— � • • — VALVE, 24" MIN. LENGTH TO LATERAL TEE OR ELL/PIPE Q <br /> . , FIRST FITTING. �^ <br /> NOTE - EACH CONNECTION I�• •. � �J J <br /> TRIANGULAR SPACING WITHIN 2�3��X�� CAPABLE OF MAX 10 GPM 45' DOWN AS REQ. TO <br /> PLANTING BED . . , , ' . , SxT TEE W/2" NIPPLE AT LATERAL PIPE DEPTH. ^ , � <br /> • MAINLINE. ROOT INTRUSION BARRIER, �NSTALL � V � <br /> PVC T�E (SXSXT)'OR • • TWO 6X2X16 CONCRETE BLOCK CAPS, ONE <br /> 90° (SXT) ' %"WIRE CLOTH GOPHER ON EACH SIDE OF THE BOX. FILTER FABRIC SLEEVE (HUNTER M <br /> SCREEN,WRAP UP SIDES. #RZWS-SLEEVE) � <br /> SPECIFIED PLANT SPACING="X" LATERAL LINE, TYP. `- � <br /> INDIVIDUAL PLANTS REPRESENTED AS: -}- � <br /> � � z <br /> � O <br /> PLANT SPACING DETAIL ;�"� TECHLINE START CONNECTION (SWING JOINT RISER) 1 " DRIP VALVE W/BASKET FILTER ROOT ZONE WATERING SYSTEM � c� <br /> q, � 5 � _.�..�_��.��___._-__y._��...�.�. __.a____��..��. �� _ � Q <br /> NTS P-CO-LAR2-06 � /� N T.S. ' P-CO-LAR2-01 � 1 1/2"= 1'-0" P-CO-LAR2-04 � 3"= 1'-0" P-CO-LAR2-37 z <br /> �._�-��' <br /> AREA PERIMETER � � � <br /> 5 Q Q � <br /> REFER TO START CONNECTION DETAIL S-03 <br /> O � <br /> o TECHLINE DRIPLINE _ _ 1� PARAPET WALL(SEE ARCHITECTURAL PLANS) � � � <br /> � <br /> �' W <br /> X / � F <br /> � � � <br /> � MANUAL FLUSH VALVE �- \ \ HYDRO-PRESSED ARCHITECTURAL SLAB,AS AVAI�ABLE V j <br /> � PLUMBED TO DRIPLINE � W <br /> j FROM MUTUAL MATERIALS, BELLEVUE, WA, PH. O W <br /> 425-452-2300 � <br /> o / \ a <br /> a <br /> i �,�' :i'` <br /> � M F ` ,�: <br /> Z <br /> = SEE EQUIPMENT LIST FOR " <br /> o / /. , -,� �;.� ..; f° �° f� �, ,. : .` ,,�'� ;�t,,''� .�.., <br /> o ROW SPACING '"� <br /> z <br /> o - . . ,� � . <br /> U / . . :. , ,.� - .� a � �� � ..A..+ � ." , ` <br /> , a a� � � � � ` <br /> _ � � ' 6 ..� , , � � ... . � � " .,, • , .•"Y. . <br /> � $'` a. ... .�•�. � � ..` . . � ,. : . ., '• ' '. ,.; <br /> N q� • . . . a , ., . • ` ir . .. � .. � .d � . . �' ;. _ . <br /> ' q. <br /> Oi .6 .< . � �6 �I ' ,f . ' a 4 '� ' 4 �A�. �' q' a '� . <br /> U ( <,.' * 'F . ,y , . .y .9� . <br /> O � � <br /> w WESTILE SCREWJACK PEDESTA�S AS ^ <br /> `" NOTE: AVAILABLE FROM BAIN &ASSOCIATES, C/, <br /> a —� <br /> � PORTLAND, OR, PHONE: 503-706-9568 <br /> � -CENTER FEED LITE LAYOUTS ALLOW 2X MAX TUBING LENGTH PERIMETER LATERALS 2"TO 4" FROM EDGE,TYP. <br /> � OF STANDARD LAYOUTS. � <br /> � -CHECK VALVE HOLDS BACK 8.5'OF WATER ARCHITECTURAL ROOF ASSEMBLY(SEE <br /> Q MAX LINE DISTANCE FOR CENTER FEED LITE LAYOUT @ 57 PSI ARCHITECTURE &STRUCTURAL PLANS) * �� <br /> � INLET; REFER TO FUL�CHART FOR ALTERNATE PRESSURES: REMOTE CONTROL VALVE WITH � � � <br /> J .33 @ 12"o.c. = 1,056 .77 @ 12" o.c. = 606' DISC FILTER AND PRV. � <br /> o .33 @ 18"o.c. = 1,504' .77 @ 18" o.c. = 864' 3/4" MIN PVC/POLY TUBING TO <br /> � .53 @ 12"o.c. = 774' 1.16 @ 12"o.c. = 460' CONNECTION; SIZE BASED UPON <br /> Z .53 @ 18"o.c. = 1,104' 1.16 @ 18"o.c. = 658' OVERALL SYSTEM DEMAND. <br /> w <br /> � <br /> w <br /> c� <br /> � a <br /> z <br /> L Q <br /> � <br /> � <br /> 8� TECHLINE HCVXR LITE IRREGULAR AREAS ARCHITECTURAL SLAB PAVING <br /> �� ;` �.________-___ __,_�.���._.v.�._R.�.__�__ _�..�._����_._..�__.__.�.���._�e.____._____.,____._v_�..�.�w_�._____ ____._�.�__._� ._ � .�_�.��..,��__.._.�,��_��._.��_._ _ �_�.�..,�. F w A S 5► � � <br /> � 9 <br /> = a ��,.� N.T.S. P-CO-LAR2-03 1"= 1'-0" P-CO-LAR2-07 ����,� B, ��q�o C� ��� <br /> � � �� ��'� �'� Z T. GRANTHAM 30 OF 32 <br /> n w <br /> � ¢ • • <br /> SHEET TITLE <br /> � � U <br /> i �� �� <v <br /> � ~ � 4 �°6 � LS-03 <br /> � W s�� �5 EX P.�2 �G`r <br /> N � q NDSCAP� P <br /> o� <br /> � z <br />