Laserfiche WebLink
____ <br /> I <br /> ix2" ANCHOR <br /> �iw i� <br /> ���L1/ <br /> STRUCTURE WALL (CEILING SIMILAR � <br /> CONICAL AS APPLICABLE) <br /> CONNECTION �12 GAX2" L SLEEVE American Property Development,Inc. <br /> WIRE CLAMP 110 110th Avenue NE suite 550 <br /> (2� ON EACH END MIN. POC DUCTWORK ael�evue,WA 98004 <br /> APPROVED TO FD SLEEVE <br /> SUPPLY DUCT INSULATED FLEXIBLE <br /> ROUND DUCT DUCT <br /> �`' (2) 12 GAGE SAFETY DAMPER SHALL HAVE <br /> WIRES ACTUATOR ACCESSIBLE FIRE DAMPER OR COMBINATION <br /> MANUAL VOLUME DAMPER SQUARE TO ROUND THROUGH THE GRILLE � FIRE/SMOKE DAMPER <br /> CEILING GRID D ADAPTER � <br /> � F�OBISON <br /> OPPOSED BLADE DAMPER GRILLE OR DIFFUSER WITH � <br /> i <br /> ING ILE FLANGE TO COVER SLEEVE � <br /> CEILING DIFFUSER <br /> � ENGINEERING, INC <br /> 19401 40TH AVE W..SUITE 302 <br /> LYNNWOOD,WA 98036 <br /> � � 206-364-3343 TE� <br /> CONTACT:JON ROBISON <br /> RETAINING ANGLE, <br /> SECURE TO SLEEVE ONLY o�0000400 <br /> NOTES: <br /> O� . RQe�O� <br /> 1. WHERE HEADROOM PERMITTED (R=D) CONNECTION Q"���OFW'�Ni��/s�O <br /> o Q-:�� O o <br /> 0 DIFFUSER SHALL BE MADE AS SHOWN. Q� �� , Z a <br /> DAMPER INSTALLATION AT GRILLE OR DIFFUSER o ���. �' :�� o <br /> DIFFUSER CONNECTION o .. F�„ � .:. o <br /> ��O `��ONAL��0�� <br /> NOT USED � DETAIL 4 DETAIL 1 °00000000 <br /> ALE: NONE M4.O SCALE: NONE M4.0 SCALE: NONE M4.O <br /> >0/>3/>7 <br /> COPYRIGHT O 2005, ALL RIGHTS RESERVED <br /> SUBMITTAL/REVISIONS <br /> # DATE DESCRIPTION <br /> RATED SHAFT DUCT INSULATION ,2/20/,� aio sET <br /> BY OTHERS 1 03/28/18 PERMIT REVISIONS <br /> NOT REQ'D. MIN <br /> SUPPLY AIR = 70' F � (B) <br /> A <br /> MIN. 1Y2" CLEAR SEE PLANS FOR NOTES: <br /> ALL AROUND DUCT DIMENSIONS �E� (A) RETAI NI NG ANGLES, LAP OPENI NG 1 " MI NI MUM <br /> (C) AND COVER CORNERS OF OPENING. <br /> (B) CLEARANCE BETWEEN WALL AND SLEEVE BOTH <br /> CAR-II REGULATOR D I MENS I ONS. <br /> 2" FOR DUCT TAKEOFF FIRE SMOKE DAMPER CD) APPROVEDECOMBI NATI ON F i RE SMOKE DAMPER. <br /> AND CONNECTION � DUCT � � � <br /> ACTUATOR �/ (E) SECURE RETAI NI NG ANGLES TO SLEEVE ONLY. <br /> (F SECURE DAMPER TO SLEEVE. <br /> 1" STEEL ANGLE f (D) (G CONNECT DUCT TO SLEEVE WITH BREAK-AWAY <br /> PER MANUFACTURER CONNECTION (TYP) . <br /> INSTRUCTIONS � <H) ACCESS DOOR, SIZE T� MEET AHJ REQUIREMENTS <br /> (F� (6x6 MINIMUM, ACCESS D�❑R SHALL BE PERMANENTLY <br /> � IDENTIFIED �N THE EXTERI�R BY A LABEL WITH LETTERS <br /> NOT LESS THAN 1/2" IN HEIGHT READING� SM�KE <br /> DAMPER OR FIRE DAMPER), <br /> 18" MIN LENGTH . <br /> REQ'D FOR OUT OF 1, C�MPLY WITH SMACNA FSRDIG AND MANUFACTURER'S � <br /> WALL FSD SLEEVE & <br /> /\nN\ INSTRUCTIONS, <br /> CAR-II REGULATOR �H� 2, DAMPER FREE AREA SHALL BE MINIMUM 90% ❑F <br /> SIDEWALL SUPPLY AREA ❑F C�NNECTING DUCT, INCREASE DAMPER � <br /> SIZE AND PR�VIDE TRANSITI❑NS T❑ C�NNECTING � <br /> ACCESS TO FSD GRILLE W/OBD ��� DUCTS AS NECESSARY TO MEET THIS REQUIREMENT, ^ ' <br /> ACTUATOR VIA REMOVING REFER TO PLANS 3, PER 2006 IBC, SECTION 716.3.2,1, COMBINATI�N ` V <br /> GRILLE & OBD FOR GRILLE SIZE FIRE/SMOKE DAMPER SHALL CL�SE UP❑N ACTIVATI�N M <br /> ❑F THE TOTAL-COVERAGE SM�KE DECTOR SYSTEM, � <br /> OUT OF WALL FIRE SMOKE DAMPER INSTALLATION <br /> . <br /> N OT U SED 8 D ETAI � 5 � <br /> > <br /> SCALE: NONE M4.0 SCALE: NONE M4.0 � � z <br /> � � � <br /> COMBINATION FIRE,/SMOKE DAMPER INSTALLATION � � c� <br /> TO OTHER CO <br /> � z <br /> DETAI � � _ <br /> I:E S NSOR SENSOR CONTROLLERS EXFAN ST � 2 � <br /> C:E C O N T R O L L E R ��� �� SCALE: NONE � � a <br /> 120VAC POWER MAKE ON CO C O M D I G I T A L I N P U T M 4.0 C� � � <br /> RISE TO 50PPM N� 5 0% S P E E D O <br /> NC S� � � <br /> F:M CO F:M CO F:M FIRE W <br /> � � W <br /> CO ALARM MAKE ON CO COM DIGITAL INPUT � <br /> �:M SENSOR i:M SENSOR I:M SENSOR CONTROL RISE TO 200PPM N� 100% SPEED � W <br /> ONTROLLE ONTROLLE ONTROLLE PANEL NC w <br /> F:FA <br /> I:FA � W <br /> � <br /> �B) <br /> F:M F:FA SCHEMATIC CONTROL WIRING DIAGRAM. �A� <br /> I: M I:FA CONTRACTOR TO COORDINATE WIRING REQUIREMENTS (E� N�TES; <br /> C:E C: FA WITH RESPECTIVE EQUIPMENT VENDORS <br /> CA) RETAINING ANGLES, LAP ❑PENING 1' MINIMUM � <br /> GARAGE EXHAUST FAN DUCT AND COVER GORNERS ❑F OPENING, � <br /> (GEF) \ /C F:M LEGEND ` CB) CLEARANCE BETWEEN WALL AND SLEEVE, � <br /> F: M F:E V r � �'E = ��� CC) STEEL SLEEVE, <br /> I:M I: E E ELECTRICAL CONTRACTOR CD) APPROVED FIRE DAMPER CCURTAIN �R BLADE � <br /> F: _ FURNISHED BY TYPE>, ,,n <br /> C:E I: _ INSTALLED BY M MECHANICAL CONTRACTOR CE) SECURE RETAINING ANGLES T❑ SLEEVE ❑NLY, V <br /> C. _ CONDUIT BY FA FIRE ALARM CONTRACTOR <F) SECURE DAMPER T❑ SLEEVE, a <br /> NOTES: <G) C�NNECT DUCT TO SLEEVE WITH BREAK-AWAY — <br /> CONTROL WIRING ��) CONNECTION <TYP), Q <br /> WIRING DIAGRAM FOR GARAGE EXHAUST FANS. <H) ACCESS D��R, SIZE TO MEET AHJ REQUIREMENTS <br /> CARBON MONOXIDE (CO) SENSOR CONTROLLER �F� C6x6 MINIMUM, ACCESS DODR SHALL BE p� <br /> CONTRACTORS TO COORDINATE ALL REQUIRED WORK. PERMANENTLY IDENTIFIED ON THE EXTERI�R BY A <br /> REFER TO MECHANICAL PLANS FOR SEQUENCE OF PROVIDE COMBINATION CO SENSOR & CONTROLLER WITH LABEL WITH LETTERS N�T LESS THAN 1/2" IN (J� <br /> OPERATION FOR FANS. LOW AND HIGH ADJUSTABLE ALARM POINT RE�AYS. (H) HEIGHT READING� SM�KE DAMPER ❑R FIRE DAMPER), <br /> -12QVAC POWER SOURCE. ._I <br /> -DRY CONTACT ALARM RELAYS RATED FOR 5A C�D120V 1, COMPLY WITH SMACNA FSRDIG AND MANUFACTURER'S <br /> REFER TO MECHANICAL PLANS FOR -ADJUSTABLE TIME DELAYS AND ACTIVATION SETPOINTS � <br /> INSTRUCTI�NS, � <br /> CO SENSOR/CONTROLLER LOCATIONS. -ELECTROCHEMICAL CO SENSOR MOUNTED ON DEVICE 2, DAMPER FREE AREA SHALL BE MINIMUM 90% ❑F W <br /> -PROVIDE AIRTEST TECHNOLOGIES #CT-1000 OR AREA ❑F C�NNECTING DUCT, INCREASE DAMPER � <br /> EQUIVALENT �G� SIZE AND PROVIDE TRANSITIONS TO C❑NNECTING w Q <br /> -SET TIME DELAY TO 4 MINUTES DUCTS AS NECESSARY TO MEET THIS REQUIREMENT, ^ N <br /> DRAWN BY <br /> GARAGE EXHAUST FAN WIRING DIAGRAM FIRE DAMPER INSTALLATI N <br /> O SHEET NUMBER <br /> DETAIL 6 DETAI � <br /> 3 <br /> SCALE: NONE M4.0 SCALE: NONE M4.0 <br />