My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE CLEARWIRE ANTENNAS 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
CLEARWIRE ANTENNAS
>
1321 COLBY AVE CLEARWIRE ANTENNAS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2021 11:28:18 AM
Creation date
1/12/2021 11:27:59 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
CLEARWIRE ANTENNAS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENVIRONMENTAL HEALTH DIVISION <br /> •7-FQ SNOHOMISH 3020 Rucker Avenue.Suite 104 <br /> , -j) HEALTH Everett, WA 98201-3900 <br /> DISTRICT 425.339.5250 FAX:425.339.5254 <br /> Deaf/Hard of Hearing:425.339.5252 (TTY) <br /> September 23,2010 <br /> (2EI <br /> CEOVEr <br /> Mersedch Schmidt,Connie Holloway, Architects Str 2 7 2010 D <br /> Providence Regional Medical Center <br /> 1321 Colby Ave PUBLIC WOR u <br /> Everett, WA 98201 <br /> Subject: Proposed,"D" Wing Bistro, Providence Med Center, 1321 Colby Ave, Everett <br /> Dear Ms. Schmidt: <br /> Your plans have been reviewed with the Rules and Regulations of the State i'oard of Health, and <br /> with the policies of the Snohomish Health District. With the addition of the folio ving conditions, the <br /> plans are approved. <br /> I. The Health District operating permit application process must be completed prior to opening for <br /> business.This is a medium risk Food Service Establishment with less than 13 seats. <br /> 2. An indirect waste drain is required for the food preparation sink, three-compartment sink, <br /> mechanical dishwasher, ice machine, pop dispenser, running water dipper well, steam table, walk- <br /> in refrigeration,and any equipment in which food is placed. <br /> 3. Ilot water must be available to all handwash sinks within 15 seconds. The hot water for the <br /> facility must not be used, at any plumbing fixture, for minimum of 6 hours prior to the <br /> preoperational inspection. This is required so that proper testing of the 15-second time <br /> requirement for hot water availability can be completed. <br /> 4. All food service equipment, both new and used, must he listed b y the National Sanitation <br /> Foundation (NSF)or equivalent for its intended use. Used and new refrigeration must be capable <br /> of holding potentially hazardous food at 41°F or below. <br /> 5. This facility has a limited amount of refrigeration equipment and lacks a food prep sink. No <br /> advanced preparation of foods that require cooling will be allowed. No retention of left over <br /> soups will he allowed. All soups must he discarded at the end of the day. <br /> 6. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, <br /> and food preparation counters and tables. A 16-inch high backsplash of plastic laminate, <br /> fiberglass-reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required <br /> on the wall behind counter top equipment taller than 16 inches. Floor to ceiling protection is <br /> required on the wall behind dishwashers. Wall protection behind mop sinks must cover the entire <br /> splash zone. Plastic coated hardboard is not acceptable. <br /> 7. All floors in the kitchen, food preparation, food service. food storage,and dishwashing areas must <br /> be surfaced with a durable. nonabsorhent,easily cleanable material. Expansion joints, scams, saw <br /> cuts and the like in concrete floors in all areas. including customer seating areas, must be filled <br /> and sealed so as to provide a smooth and cleanable surface. <br /> S. The ceiling above the lived preparation areas must be nonperforated, nonabsorbcnt, smooth and <br /> easily cleanable. <br /> 9. Plumbing must meet state and local codes. <br /> y2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.