Laserfiche WebLink
GENERAL CONSTRUCTION NOTES � <br /> : un�s ace <br /> 1.ALL CONSTRUCTION SHALL COMPLY WITH THE(201518C WITH WAC 51-50,20151EBC WITH DIMENSION: ADDITIONAL GENERAL CONTRACTOR RESPONSIBILITY: 1.THE GENERAL CONTRACTOR SHALL PROVIDE SUBMITTALS FOR REVIEW&APPROVAL BY <br /> WAC 51-50,AND WAC 51-11),AND ALL APPLICABLE LOCAL CODES,ORDINANCES,AND 1.ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTiNG CONDITIONS IS 1.GENERAL CONTRACTOR IS RESPONSIBLE TO PROVIDE FINAL AS BUILT DRAWINGS UNISPACE.G.C. IS TO PROVIDE TWO SAMPLES OF THE SPECIFIED MATERIALS. SUBMITTALS 701 5th Ave., Suite 6730 <br /> STANDARDS. IN CASE OF ANY CONFLICT WHERE THE METHODS OR STANDARDS OF GIVEN AS THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. INCLUDING ARCHITECTURAL,MECHANICAL,ELECTRICAL, PLUMBING AND LIFE SAFETY TO SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: DRAW DOWNS OF ALL PAINTS, Seattle WA 98104 USA <br /> INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE DO NOT SCALE DRAWINGS.THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS AND CLIENT IN FINAL CLOSE OUT DOCUMENTS. SAMPLES OF ALL CARPETS,ALL SPECIFIED FLOOR BASE, SAMPLES OF ALL WALL FINISHES, +1 206 270 7000 <br /> REQUIREMENTS OF THE LAWS OF ORDINANCES,THE LAWS OR ORDINANCES SHALL DIMENSIONS AND SHALL NOTIFY UNISPACE OF ANY DISCREPANCIES OR CONDITIONS OR 2.THE CONTRACTOR WILL INSPECT THE PREMISES IMMEDIATELY TO CHECK EXISTING SAMPLES OF SPECIFIED CABINET FINISHES, SAMPLES OF CEILING GRID&CEILING TILE, www.unispace.com <br /> GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS. CONDITIONS ADVERSELY EFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE WORKING CONDITIONS.SHOULD THE CONTRACTOR FIND CONDITIONS WHICH HE/SHE PACKAGES OF LIGHTING SUBMITTALS, DOOR&HARDWARE, MILLWORK SHOP DRAWINGS, <br /> 2.THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF THE WORK. BELIEVES WOULD IMPEDE HISIHER WORK,THEN SUCH CONDITIONS MUST BE REPORTED MILLWORK HARDWARE SUBMITTALS, ETC. PROVIDE(3)12"X12"WOOD VENEER <br /> ARCHITECT OF RECORD AND SHALL NOT BE REPRODUCED OR USED FOR ANY OTHER 2. DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLUMNS AND FINISH IMMEDIATELY TO THE OWNER. FAILURE TO SO ADVISE WILL CONSTITUTE NOTICE THAT SUBMITTALS. Consultants: <br /> PURPOSE EXCEPT BY WRITTEN AGREEMENT. GWB FACE OF PARTITIONS, UNLESS NOTED OTHERWISE. DOOR CASED OPENINGS THE CONTRACTOR IS FULLY SATISFIED WITH THE EXISTING CONDITIONS AND THAT HE/SHE 2.THE GENERAL CONTRACTOR SHALL INCLUDE IN HIS/HER ESTIMATE ALL COSTS, <br /> 3. SECURE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE,CONSTRUCTION, WITHOUT LOCATION DIMENSIONS ARE TO BE FOUR(4) INCHES FROM THE FACE OF THE INTENDS TO PERFORM HIS/HER OBLIGATIONS WITH NO ALLOWANCE EITHER IN TIME OR (INCLUDING OVERTIME WORK) FOR REMOVAL, NEW INSTALLATION&REINSTALLATION <br /> LABOR, HEALTH AND LICENSING.CONTRACTOR SHALL FURTHER POST ALL BONDS AND ADJACENT PARTITION OR CENTERED BETWEEN PARTITIONS. MONEY FOR ANY IMPEDIMENTS TO THIS WORK. WORK FOR ANY PLUMBING, CEILING(TAKE-DOWN&REINSTALLATION), ELECTRICAL, <br /> SECURE ALL INSURANCE REQUIRED BY LAW OR CONTRACT, FORWARDING PROOF OR 3.ALL ANGLES ARE AT 90 OR 45 DEGREES UON. 3.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING HIS/HER BEST SKILL TELEPHONE COMMUNICATIONS EQUIPMENT OR HVAC WORK ON CEILING PLENUM. <br /> SUCH ACTIONS TO THE LANDLORD PRIOR TO COMMENCEMENT OF CONSTRUCTION. AND ATTENTION. HE/SHE SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION, 3.THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT&COMPLETE SET OF <br /> 4.WORK NOT INCLUDED IN THIS CONTRACT SHALL BE MARKED"N.I.C."OR SPECIFICALLY CONSTRUCTION: AND/OR INSTALLATION MEANS, METHODS,TECHNIQUES,SEQUENCES OR PROCEDURES CONSTRUCTION DRAWINGS ON SITE DURING ALL PHASES OF CONSTRUCTION FOR USE BY <br /> ASSIGNED TO ANOTHER PARTY. 1. GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT ABOUT SITE CONDITIONS THAT AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THIS CONTRACT. ALL TRADES. <br /> 5. CONTRACTORS SHALL VISIT SITE, REVIEW THE DRAWINGS AS SUBMITTED BY THE REQUIRE ADDITIONAL INTERIOR WALLS SUPPORT OR STRUCTURAL DETAILS. 4.ALL WORK SHALL BE EXECUTED IN A NEAT AND WORKMANLIKE MANNER ACCEPTABLE TO 4.ALL EXISTING APPURTENANCES NOT BEING REMOVED SHALL BE REFURBISHED WHERE <br /> ARCHITECT,AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO 2. INVESTIGATE AND VERIFY LOCATIONS OF EXISTING STRUCTURAL, PLUMBING, THE OWNER. REQUIRED.ANY LOOSE ITEMS TIGHTENED(CEILING EXIT SIGNS, ETC.)&ANY MISSING <br /> BIDDING OR CONSTRUCTION. MECHANICAL,AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS AND 5. UNLESS OTHERWISE SPECIFICALLY NOTED,THE CONTRACTOR SHALL PROVIDE AND PAY PARTS REPLACED BY THE GENERAL CONTRACTOR TO ACHIEVE A FINISHED FIRST CLASS <br /> 6.ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST NOTIFY THE ARCHITECT OF NAY AND ALL DISCREPANCIES PRIOR TO PROCEEDING WITH FOR ALL LABOR, MATERIALS, EQUIPMENT,TOOLS, CONSTRUCTION EQUIPMENT,AND INSTALLATION&APPEARANCE. <br /> RECOMMENDATIONS OR WRITTEN DIRECTIONS. THE WORK. MACHINERY,TRANSPORTATION, OTHER FACILITIES AND SERVICES NECESSARY FOR 5.ALL REQUIRED EXITS,WAYS OF APPROACH THERETO,&WAYS OF TRAVEL FROM THE EXIT <br /> 7.WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE 3. COORDINATE CONSTRUCTION SCHEDULING WITH BUILDING OWNER TO ALLOW ONGOING PROPER EXECUTION OF THE COMPLETION OF THE WORK.THE CONTRACTOR WARRANTS INTO THE STREET SHALL CONTINUOUSLY BE MAINTAINED FREE FROM ALL OBSTRUCTIONS <br /> WORK,THE DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. OPERATION OF THE FACILITY DURING CONSTRUCTION. TO THE OWNER AND BUILDING MANAGEMENT THAT ALL MATERIALS AND EQUIPMENT &IMPEDIMENTS FOR UNOBSTRUCTED EGRESS IN THE CASE OF FIRE OR OTHER <br /> 8.WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS 4. PROVIDE BLOCKING AS REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. FURNISHED UNDER THIS CONTRACT WILL BE NEW UNLESS OTHERWISE SPECIFIED,AND EMERGENCY. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION,ALL <br /> INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS 5. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. THAT ALL WORK WILL BE GOOD QUALITY, FREE FROM FAULTS AND DEFECTS AND IN EXISTING EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS SHALL BE <br /> ARE REQUIRED TO PROPERLY COMPLETE THE WORK. 6. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS.ALL WORK NOT SO CONFORMING CONTINUOUSLY MAINTAINED. � <br /> 9. VERIFY ALL"BUILDING STANDARDS"WITH BUILDING OWNER PRIOR TO BEGINNING ANY 7. PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED BY DEMOLITION AND NEW TO THESE STANDARDS MAY BE CONSIDERED DEFECTIVE. IT IS UNDERSTOOD THAT NO 6. EACH CONTRACTOR SHALL MAKE ALL REQUIRED ARRANGEMENTS FOR DELIVERY OF <br /> WORK. HOWEVER,THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT CONSTRUCTION TO RECEIVE NEW SCHEDULE FINISHES.ALL SURFACES ARE TO HAVE INFERIOR OR NON-CONFORMING WORK OF THE MATERIALS WILL BE ACCEPTED WHETHER EQUIPMENT&IOR MATERIALS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR <br /> DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF.THE "LIKE-NEW"APPEARANCE. DISCOVERED AT THE TIME THEY ARE INCORPORATED IN THE WORK OR AT ANY TIME TO CHECK THE RULES&REGULATIONS GOVERNING WORK ON THE PREMISES, INCLUDING <br /> CONTRACTOR AGREES TO DEFEND, INDEMNIFY,AND HOLD THE ARCHITECT HARMLESS 8. STUD HEIGHT AND SPACING LIMITATION OF STEEL FRAMING COMPONENTS SHOULD BE BEFORE OR AFTER THE FINAL ACCEPTANCE. IF REQUIRED BY THE OWNER,THE THE FOLLOWING: <br /> FROM ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. IN COMPLIANCE WITH ASTM C 754 FOR MAXIMUM DEFLECTION AND MINIMUM LATERAL CONTRACTOR SHALL FURNISH SATISFACTORY EVIDENCE AS TO THE KIND AND 7. DATE&TIME OR DELIVERY SHALL BE ESTABLISHED IN CONJUNCTION WITH THE <br /> 10.LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT LOADING REQUIREMENTS. INSTALLATION OF MATERIALS AND EQUIPMENT. PERSON HAVING JURISDICTION OVER PREMISES. OVERTIME CHARGES&/OR ANY <br /> THEM FROM DAMAGE.THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR 9.ALL DEMOLISHED MATERIALS TO BE RECYCLED BY AN APPROVED RECYCLER. 6.THE WARRANTIES AND GUARANTEES PROVIDED IN THE CONSTRUCTION DOCUMENTS NECESSARY EXPENSE SHALL BE PAID BY CONTRACTOR REQUIRING SERVICE. <br /> REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN SHALL BE IN ADDITION TO AND NOT IN LIMITATION OF ANY OTHER WARRANTY AND 8. BUILDING CONDITIONS, INCLUDING SIZE&LOADING CAPACITY OF ELEVATORS, SIZE <br /> CONJUNCTION WITH THE EXECUTION OF THIS WORK. LiFE SAFETY: GUARANTY OR REMEDY REQUIRED BY LAW OR THE CONSTRUCTION DOCUMENTS. OF DOORWAYS,CORRIDORS,WINDOW OPENINGS, ETC., SHALL BE CHECKED BY THE <br /> 11.VERIFY AND CONFORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UNLESS 1. IF NECESSARY, PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RELATED 7.ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE(1)YEAR AFTER COMPLETION CONTRACTOR BEFORE DELIVERY TO ASSURE ITEMS WILL FIT INTO SPACE. <br /> OTHERWISE NOTED IN THE PLANS OR SPECIFICATIONS. ELEMENTS AS REQUIRED BY CODE. UNLESS OTHERWISE SPECIFIED,AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN 9. ALL CHARGES INVOLVING THE INSTALLATION&/OR OPERATION OF A HOIST SYSTEM, <br /> 12.ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A 2. FIRE EXTINGUISHERS:VERIFY LOCATION,TYPE,AND SIZE PER FIRE MARSHAL PROPOSAL AGREEMENT.ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ETC., MUST BE IF REQUIRED,SHALL BE BORNE BY THE CONTRACTOR USING THE SYSTEM. CHARGES <br /> CLEAN CONDITION AT ALL TIMES. REQUIREMENTS.CONTRACTOR TO PROVIDE ALL TEMPORARY AND PERMANENT FIRE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER,AND WITHIN FIVE(5)DAYS AFTER INVOLVING THE TEMPORARY REMOVAL&REINSTALLATION OF WINDOW SASH&IOR <br /> 13. PROTECT ADJACENT WORK AND REPAIR ANY DAMAGE AT CONTRACTOR'S OWN EXTINGUISHERS REQUIRED UNDER N.F.P.A. 10 MOST RECENT EDITION AND APPROVED NOTICE IS GIVEN. FIXED PANELS REQUIRED FOR DELIVERY SHALL BE BORNE BY THE CONTRACTOR. ' <br /> EXPENSE. BY THE FIRE MARSHAL. CONFIRM ACCESSIBILITY OF LOCATION WITH FIRE ALARM PRIOR 8.THE ARCHITECT AND THE ARCHITECT'S CONSULTANTS SHALL NOT HAVE ANY 26.THE GENERAL CONTRACTOR, SUBCONTRACTOR&TENANTS CONTRACTOR SHALL <br /> 14.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN TO INSTALLATION.PROVIDE FINISHED CABINETS TO MATCH BUILDING STANDARD FOR RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF SUBMIT CERTIFICATES TO THE BUILDING MANAGER&OWNER UPON COMPLETION OF WORK, <br /> ACCORDANCE WITH ALL APPLICABLE SAFETY CODES. EXTINGUISHERS AT ALL EXPOSED LOCATIONS. OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT INCLUDING BUT NOT LIMITED TO THE FOLLOWING: <br /> 15.THE CONTRACTOR SHALL INDEMNIFY AND HOLD THE BUILDING 3. FIRE EXTINGUISHERS AND CABINETS SHOULD BE LOCATED SO THAT THE TOP OF THE SITE, INCLUDING, BUT NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED A. FIREPROOF WOOD TEST REPORT(IF REQUIRED). <br /> OWNERIARCHITECT/ENGINEER HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR EXTINGUISHER OR CABINET IS NO HIGHER THAN 48"AFF AND THE TOP OF THE BIPHENYL(PCB)OR OTHER TOXIC SUBSTANCES. B. ELECTRICAL, PLUMBING&AIR CONDITIONING CERTIFICATES ISSUED BY: <br /> DAMAGE PROPERTY CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR,HIS/HER EXTINGUISHER OR CABINET HANDLE IS AT LEAST 36"AFF. 9.THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, STANDARDS FORM -DEPARTMENT OF WATER SUPPLY,GAS&ELECTRICITY <br /> AGENTS, EMPLOYEES, OR SUBCONTRACTORS. 4.AT SEMI-RECESSED FIRE EXTINGUISHER CABINETS WRAP ADDITIONAL LAYER(S)OF OF TNE AMERICAN INSTITUTE OF ARCHITECTS, CURRENT EDITION,SHALL APPLY TO ALL -BOARD OF FIRE UNDERWRITERS <br /> 16.APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY TYPE'X'GYPSUM WALL BOARD INTO THE CABINET CAVITY TO MAINTAIN SPECIFIED FIRE WORK IN THIS CONTRACT, EXCEPT AS SPECIFICALLY MODIFIED BELOW&IOR BY THE <br /> WORKERS.ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMAT{ON AS WE�L RATED REQUIREMENT. REFER TO WALL CONSTRUCTION LEGEND FOR ADDITIONAL AGREEMENT. <br /> AS ALL REVISIONS,ADDENDA,AND CHANGE ORDERS.THE CONTRACTOR SHALL ALSO INFORMATION. 10. PRIOR TO BEGINNING ANY WORK THE GENERAL CONTRACTOR SHALL FURNISH A <br /> MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, 5. PROVIDE AND INSTALL FIRE EXTINGUISHER SIGNAGE(5"X6")ABOVE EACH FIRE CONSTRUCTION SCHEDULE SHOWING THE CHRONOLOGICAL PHASE OF HIS/HER WORK & <br /> ADDENDA,AND CHANGE ORDER,ON THE PREMISES AT ALL TIMES WHICH ARE TO BE EXTINGUISHER OR CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED REQUIREMENT. ALL RELATED WORK FOR THE COMPLETION OF THE PROJECT.THIS SCHEDULE SHALL <br /> UNDER THE CARE OF THE JOB SUPERINTENDENT. REFER TO WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. INDICATE ALL ORDERING LEAD TIMES, LENGTH OF TIME FOR EACH PHASE, ITS START& , <br /> 17. PROVIDE COMPLETE SECURITY OF THE TENANT SUITE WHILE JOB IS IN PROGRESS AND 6. EXIT SIGNS AND EXIT ILLUMINATION SHALL CONFORM TO THE 201516C WITH WAC 51-50 COMPLETION,WITH A PROJECTED COMPLETION DATE. <br /> UNTIL THE JOB IS COMPLETE. &20151EBC WITH WAC 51-50 AND EVERETT FIRE MARSHALL REQUIREMENTS. 11.ALL UNISPACE DRAWINGS&ALL CONSTRUCTION NOTES ARE COMPLEMENTARY,& WHAT <br /> 18.AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE,LEAVING SPACE CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTtNG AND EXIT LIGHTING AS IS CALLED FOR BY EITHER WILL BE BINDING AS IF CALLED FOR BY ALL.ANY WORK SHOWN <br /> CLEAN,WASH ALL WINDOWS AND GLASS, POLISH ALL HARDWARE AND FIXTURES. REQUIRED BY THE EVERETT FIRE AND BUILDING DEPARTMENTS. CONFIRM OR REFERRED TO ON ANY ONE SET OF DRAWINGS SHALL BE PROVIDED AS THOUGH <br /> REPLACE AND PATCH AREAS OF CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR ACCEPTABILITY OF LOCATIONS WITH FIRE MARSHAL BEFORE INSTALLATION. SHOWN ON ALL RELATED DRAWINGS. <br /> MECHANICAL ADJUSTMENT. CONTRACTOR SHALL PROVIDE AND INSTALL AUDIBLE ALARMS IN ACCORDANCE WITH 12. BEFORE SUBMITTING A PROPOSAL,ALL CONTRACTORS SHALL VISIT THE PREMISES, <br /> 19. MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE,ODOR, FUMES,OR (201516C WITH WAC 51-50&20151EBC WITH WAC 51-50). CONTRACTOR SHALL PROVIDE FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS&SATISFY THEMSELVES AS TO <br /> VIBRATION.AT THE END OF CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY AND INSTALL ALL SMOKE DETECTORS AND SMOKE DETECTION AS REQUIRED UNDER THE NATURE&SCOPE OF THE WORK&THE DIFFICULTIES THAT ATTEND TO ITS <br /> CLEAN ALL AREAS SOILED BY CONSTRUCTION ACTIVITIES INCLUDING THOSE IN WHICH NO CHAPTER 7 OF THE(201516C WITH WAC 51-50&20151EBC WITH WAC 51-50).THE EXECUTION. THE SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT <br /> WORK WAS DONE. INSTALLATION OF THE ABOVE NOTED SYSTEM SHALL INCLUDE THE CONNECTION TO SUCH AN EXAMINATION HAS BEEN MADE&LATER CLAIMS FOR LABOR, EQUIPMENT,OR <br /> 20. LATHING, PLASTER,AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER AND/OR MODIFICATION OF THE EXISTING BUILDING SYSTEMS,AS NECESSARY. MATERIAL REQUIRED FOR DIFFICULTIES ENCOUNTERED,WHICH COULD HAVE BEEN <br /> 25 OF THE INTERNATIONAL BUILDING CODE. 7. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR FORESEEN HAD SUCH AN EXAMINATION BEEN MADE,WILL NOT BE RECOGNIZED. <br /> 21.ALL GLASS AND GLAZING SHALL COMPLY WITH THE(201518C WITH WAC 51-50&2015 ANY SPECIAL KNOWLEDGE OR EFFORT. 13.ALL CONTRACTORS SHALL CONTACT THE BUILDING MANAGEMENT TO DETERMINE THE <br /> IEBC WITH WAC 51-50) AND THE U.S. PRODUCT SAFETY COMMISSION:SAFETY 8. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED,OR DISPENSED IN THIS RULES OF THE BUILDING OWNER FOR CONSTRUCTION TO DETERMINE WHEN&HOW � <br /> STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS(42 FR 1426:16 CFR PART 1201). OCCUPANCY EXCEPT AS PROVIDED IN NFPA STANDARD 30 AND THE(201518C WITH WAC DELIVERIES CAN BE MADE(SEE BELOW),WHAT PHASES OF CONSTRUCTION CAN BE DONE <br /> 22.VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND 51-50&20151EBC WITH WAC 51-50). PERMIT MAY BE REQUIRED. ON REGULAR OR OVERTIME,&IN GENERAL ANY SPECIAL BUILDING REQUIREMENTS WHICH <br /> WINDOW MANUFACTURERS. 9.ALL DRAPES, HANGINGS,CURTAINS,AND ALL OTHER DECORATIVE MATERIALS THAT WILL AFFECT THEIR WORK(IF OVERTIME WORK IS REQUIRED BY ANY TRADE,APPROVAL <br /> 23. CONSTRUCTION WALLS PLUMB AND SQUARE WITH EXISTING STRUCTURE AND NEW WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE FROM MUST BE OBTAINED PRIOR TO THE EXECUTION OF ANY WORK INCLUDING COST). THE <br /> CONSTRUCTION UON. NONFLAMMABLE MATERIAL,OR SHALL BE TREATED AND MAINTAINED IN A FIRE GENERAL INTENT IS THAT ALL CONSTRUCTION WORK SHALL BE DONE ON REGULAR TIME <br /> 24.COORDINATION;THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE RETARDANT CONDITION BY MEANS OF A FLAME RETARDANT SOLUTIONS OR PROCESS EXCEPT NOISE GENERATING CONSTRUCTION. <br /> VERIFICATION AND COORDINATION OF THE WORK OF ALL TRADES TO ASSURE APPROVED BY THE FIRE MARSHAL.PROVIDE A CERTIFICATION TO THIS EFFECT. EXIT 14.THE GENERAL CONTRACTOR, HIS/HER SUBCONTRACTOR&ANY OTHER CONTRACTOR <br /> COMPLIANCE WITH THE DRAWINGS. DOORS,EXIT LIGHTS,AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED INVOLVED IN THIS PROJECT SHALL TAKE NOTE THAT ANY COST CAUSED BY DEFECTIVE OR <br /> 25.ALL CONSTRUCTION AND DESIGN TO BE IN COMPLIANCE WITH UNISPACE DESIGN AND OR OBSTRUCTED BY ANY DECORATIVE MATERIAL. MINIMUM FLAME SPREAD ILL-TIMED WORK AS A RESULT OF, BUT NOT LIMITED TO INFERIOR WORKMANSHIP OR <br /> CONSTRUCTION GUIDELINES. CLASSIFICATION OF INTERIOR FINISHES SHALL CONFORM TO THE(201516C WITH WAC MATERIALS, IMPROPER SCHEDULING OR DELINQUENT ORDERING SHALL BE BORNE BY THE <br /> 26. REFER TO CLIENT'S BID FORMS AND EXECUTED CONTRACT FOR CONSTRUCTION FOR 51-50&20151EBC WITH WAC 51-50). PARTY RESPONSIBLE THEREFORE. <br /> FULL LIST OF CONTRACT DOCUMENTS. 10.ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY 15.THE USE OF THE WORDS"PROVIDE"OR"PROVIDED" IN CONNECTION WITH ANY ITEM <br /> 27.THE DRAWINGS, CLIENT'S STANDARD SPECIFICATIONS,AND ALL OTHER CONTRACT SHOWING THE SPECIFIC RATING. SPECIFIED IS INTENDED TO MEAN, UNLESS OTHERWISE NOTED,THAT WHICH SHALL BE <br /> DOCUMENTS ARE COMPLEMENTARY.WHERE CONFLICTS OR DIFFERENCES OCCUR FURNISHED& INSTALLED,&CONNECTED WHERE SO REQUIRED. <br /> CONTRACTOR SHALL BRING THEM TO THE ATTENTION OF UNISPACE DURING BID.WHERE 16.WHERE THE TERMS"APPROVED EQUAL","OTHER APPROVED","EQUAL TO", � �� <br /> DIFFERENCES ARE NOT BROUGHT TO UNISPACE'S ATTENTION DURING BID,THE COSTLIER "ACCEPTABLE"OR THE OTHER GENERAL QUALIFYING TERMS ARE USED IN THESE NOTES, Stamp: �� � _.. , <br /> OR MORE RESTRICTIVE SHALL BE DEEMED THE CONTRACT REQUIREMENT. IT SHALL BE UNDERSTOOD THAT REFERENCE IS MADE TO THE RULING&JUDGMENT OF °��„ �� ' <br /> 28.THE CONTRACTOR SHALL NOTIFY UNISPACE OF ANY DISCREPANCIES BETWEEN THE UNISPACE. k ""'` �' '' <br /> � �� � <br /> CONSTRUCTION DOCUMENTS AND ANY FIELD CONDITIONS,WHICH MAY CAUSE DEVIATION ' <br /> � � <br /> FROM THE CONSTRUCTION DOCUMENTS, PRIOR TO SUBMITTING BIDS. � � �: �;x,�4>j w ; <br /> r � , x <br /> w re�y::�+3-��� „1^t..t;;��3 g <br /> � <br /> GENERAL SYMBOLS STANDARD ABBREVIATIONS �gry�� � � --- <br /> �3 <br /> � ,<�'` � �� <br /> �� PROJECT NORTH & -AND GA- GAUGE PERF - PERFORATED <br /> -AT GALV- GALVANIZED PERP - PERPENDICULAR <br /> �----TRUE NORTH @ - CENTER �INE GB - GRAB BAR PL- PLATE <br /> - # - POUND GC-GENERAL CONTRACTOR PLBG - PLUMBING <br /> -- ---- ± -TOLERANCE DIMENSION GEN -GENERATOR PR- PAIR <br /> NJ.C. AREA NOT IN CONTRACT GFRC - GLASS FIBER REINFORCED CONCRETE PREFAB- PREFABRICATED <br /> - ' A/E -ARCHITECT/ ENGINEER GFRG - GLASS FIBER REINFORCED GYPSUM PT- PRESSURE TREATED <br /> RM.NAME� ACT-ACOUSTIC CEILING TILE GL- GLASS PTD - PAINTED <br /> 101 _ ROOM NAME ADA-THE AMERICANS WITH DISABILITIES ACT GWB- GYPSUM WALL BOARD PVC- POLYVINYL CHLORIDE <br /> 150 SFR ROOM/AREA NUMBER ADJ -ADJACENT <br /> AREA AFF -ABOVE FINISHED FLOOR HB- HOSE BIBB QTY- QUANTITY <br /> AH -AIR HANDLER HC - HOLLOW CORE <br /> r�, ALT-ALTERNATE HT- HEIGHT R- RADIUS OR (STAIR) RISERS ' <br /> S�M---REF. TYPE (IF APPLICABLE) <br /> 1 APPROX-APPROXIMATELY HM - HOLLOW METAL RAD- RADIATOR <br /> � � 6_22 \---DETAIL REFERENCE NUMBER ARCH -ARCHITECT HO - HOLD OPEN RCP- REFLECTED CEILING PLAN <br /> L" � �. <br /> --DETAIL REFERENCE SHEET HORIZ- HORIZONTAL RD- ROOF DRAIN <br /> �� ------AREA OF DETAIL BD - BOARD HP - HIGH POINT REF - REFERENCE <br /> BLDG - BUILDING HVAC - HEAT, VENTILATION &AIR CONDITIONING REFR- REFRIGERATOR 2 ISSUEDFORPERMIT 05/07/19 IMH �c <br /> � S�M - REF. TYPE IF APPLICABLE) BM - BEAM REINF - REINFORCED OR REINFORCING 1 PRICING SET 04/26119 IMH �c <br /> _____ ------ <br /> --- EXTERIOR �LEVATION ID- INSIDE DIAMETER REQD - REQUIRED REv �EscRiPTioN ----- �ArE BY cHK <br /> A1-101 �J R CAB- CABINET IN - INCH OR INCHES RH - RIGHT HAND Key Plan <br /> --�N�NUMBER CG - CORNER GUARD INSUL- INSULATION RHR- RIGHT HAND REVERSE tf`'�>; <br /> � CLG - CEILING INT- INTERIOR RM - ROOM � ``' � <br /> , �_ <br /> CLR- CLEAR RO- ROUGH OPENING °�'� '� � ���= . <br /> 1 A2-222 ��ELEVATION NUMBER TYP, CMU - CONCRETE MASONRY UNIT JAN -JANITOR RWL - RAIN WATER LEADER �'.�L � � � �����= <br /> �� SHEET NUMBER COL- COLUMN ` � `� �� � �� <br /> ��.� <br /> � CONC - CONCRETE KD - KNOCKED DOWN SAFB - SOUND ATTENUATION FIBER BLANKET � � - �� �� �'`��� <br /> ` � '��_ ri `�_ <br /> CONT-CONTWUOUS KO- KNOCKOUT SF - SQUARE FOOT OR FEET ,�, � �� �� _ . <br /> s�M REF. TYPE (IF APPLICABLE) CYL- CYLINDER SIM - SIMILAR ' ��- � �'� � . , <br /> � . . � <br /> g_2 �� SECTION NUMBER L- LENGTH OR LEFT SK- SINK �4�� ��� ,,, <br /> ��--SHEET NUMBER DEMO- DEMOLITION LAB- LABORATORY SPEC- SPECIFICATIONS ��; �` � � : " ��� <br /> DEPT- DEPARTMENT LAM - LAMINATE SQ- SQUARE � �- ��=��' ', <br /> DIA- DIAMETER LAV- LAVATORY ST- STREET �� , � <br /> S�M ----REF. TYPE (IF APPLICABLE) DIM - DIMENSION LB - POUND STC- SOUND TRANSMISSION CLASS �`�`�` -�� `� z <br /> - �" M <br /> g_22 �---DETAIL SECTION NUMBER DISP- DISPENSER LF - LINEAR FOOT OR FEET STD- STANDARD � <br /> ---SHEET NUMBER <br /> DIV- DIVISION LH - LEFT HAND STG - STORAGE Client/Project Name/Address: � <br /> DN - DOWN LHR- LEFT HAND REVERSE STL- STEEL � <br /> m <br /> ; 22 ' GRID LINE NUMBER DWG - DRAWING LIN - LINEAR STN - STONE FLU KE 2G � <br /> _ LP - LOW POINT STR- STRUCTURAL J <br /> LEVEL NAME EA- EACH LTG - LIGHTING <br /> _ T-TREADS STAIRS 6920 SEAWAY BLVD � <br /> LEVEL 0''� � EIFS EXTERIOR INSULATION FINISH SYSTEM � ) EVERETT, WA 98203 W <br /> 12'-6" EJ - EXPANSION JOINT MACH - MACHINE T&G -TONGUE AND GROOVE o� <br /> �'--- LEVEL ELEVATION EL- ELEVATION MAX- MAXIMUM TBD- TO BE DETERMINED ° <br /> ELEC- ELECTRICAL MDF- MEDIUM DENSITY FIBERBOARD TEL- TELEPHONE N, <br /> Q REVISION NUMBER ELEV- ELEVATOR MECH - MECHANICAL TEMP - TEMPORARY Drawing Title: J <br /> EMER- EMERGENCY MFR- MANUFACTURER TOFF -TOP OF FINISHED FLOOR Q <br /> ALIGN TO INDICATED ENGR - ENGINEER MIN - MINIMUM T.O. - TOP OF G EN ERAL NOTES� � ' <br /> SURFACES EP - ELECTRICAL PANEL MIR- MIRROR TPO-THERMOPLASTIC-POLYOLEFIN ROOFING o <br /> EPDM - ETHYLENE PROPYLENE DIENE MONOMER MISC- MISCELLANEOUS TV-TELEVISION OR MONITOR SYM BO LS & w' <br /> ALIGN TO INDICATED EQ - EQUAL MO - MASONRY OPENING TYP - TYPICAL � <br /> AL N OPPOSITE EQUIP- EQUIPMENT MTD - MOUNTED ABBREVIATIONS �' <br /> SURFACES EX/ EXIST- EXISTING MTL- METAL UL- UNDERWRITERS LABORATORY o <br /> N <br /> � SHEET- KEYNOTES EXH - EXHAUST UON - UNLESS OTHERWISE NOTED � <br /> N/A- NOT APPLICABLE UPS - UNINTERRUPTIBLE POWER SUPPLY status: � <br /> FA- FIRE ALARM NIC- NOT IN CONTRACT UV- ULTRAVIOLET o <br /> � CENTER LINE FACP - FIRE ALARM CONTROL PANEL NOM - NOMINAL PERMIT SET @ <br /> FD - FLOOR DRAIN NTS - NOT TO SCALE VAC - VACUUM @ <br /> FDC - FIRE DEPARTMENT CONNECTION VCT- VINYL COMPOSITION TILE _ _ �' <br /> FE - FIRE EXTINGUISHER OA- OVERALL VERT- VERTICAL Drawn By:IMH Checked By:PM N � <br /> Scale: 12" =1'-0" Date: � <br /> FEC - FIRE EXTINGUISHER CABINET O.C. - ON CENTER VEST- VESTIBULE " <br /> -- --___- ---- � <br /> FHC - FIRE HOSE CABINET OD-OUTSIDE DIAMETER VIF - CONTRACTOR TO VERIFY IN FIELD Project Number: S EA'OOOv�7 a <br /> OFCI - OWNER FURNISHED/CONTRACTOR <br /> FIN - FINISH INSTALLED W -WEST � <br /> FLR- FLOOR OFOI - OWNER FURNISHED/OWNER INSTALLED W/-WITH Drawina Number: Revision: :- <br /> 0 <br /> FT- FOOT OR FEET OPP - OPPOSITE W/0- WITHOUT � <br /> N <br /> FTG - FOOTING WC - WATER CLOSET � � <br /> FTR - FIN TUBE RADIATION WP- WORKING POINT � <br /> � <br /> Z <br /> FURN - FURNITURE . . o a <br />