Laserfiche WebLink
Sales and <br /> Service <br /> NOTES AND EXCEPTIONS: <br /> This proposal is based on Spec sections 26 24 13 26 27 16&26 32 13 provided by City of Everett and drawings SWBD GSB2 <br /> Rev2 WBD SSB-1 Rev1 SWBD SSB-2A Rev 1 SWBD SSB-2B Rev 1 provided by SAZAN.We know of no addenda, drawings, or <br /> relevant spec sections. <br /> #26 32 13 <br /> 2.8 E-Calcium Silicate Exhaust Insulation By Installing Contractor. Not Provided By Cummins <br /> 2.10 Oil Heaters Not Provided. Not Factory Option <br /> 2.12 RTDs not provided on 1000 KW unit or 500 KW trailer. Not Factory Option- <br /> #26 24 13 <br /> 1.5.A.1.b.6&7—These drawings not available at submittal time. <br /> 1.5.A.1.c—Not available at submittal time. <br /> 3.1 —Installation by others <br /> 3.4—By others <br /> 3.5—By others <br /> •Approval from the local utility MUST be obtained before this equipment may be connected, and/or operated with the facility bus. <br /> •The price contained in this quotation is based on the sequence of operation either referenced to, and/or described in this document as <br /> it pertains to the equipment indicated on the previous pages.Any variations to this sequence, and/or any additional circuit breakers, <br /> switches,fuses, etc.,to supply, monitor and/or control will require re-pricing. <br /> accn orin will bn the responsibility of the quoting distributor <br /> • Engine/Generator control and monitoring, voltage regulation, paralleling, synchronizing, and some protective circuits will be <br /> accomplished via PowerCommand TM Control and/or PowerCommand TM Paralleling. <br /> 1. The digital display on the PowerCommand genset paralleling control includes a synchroscope function for monitoring the <br /> phase difference(in degrees,faster or slower than bus) between the generator set and the system bus.An indicator is provided to <br /> advise the operator when the generator set is within specified paralleling parameters. <br /> 2. Paralleling control functions(synchronizing, load sharing, etc.)and paralleling protective functions (0/U bus voltage/frequency, <br /> overload, and phase protection) are provided by the PowerCommand generator set controls that are resident on the gensets. <br /> COVID 19 SUPPLEMENTAL STATEMENT <br /> AS A RESULT OF THE OUTBREAK OF THE DISEASE COVID-19 ARISING FROM THE NOVEL CORONAVIRUS,TEMPORARY <br /> DELAYS IN DELIVERY, LABOUR OR SERVICES FROM CUMMINS AND ITS SUB-SUPPLIERS OR SUBCONTRACTORS MAY <br /> OCCUR. AMONG OTHER FACTORS, CUMMINS' DELIVERY OBLIGATIONS ARE SUBJECT TO CORRECT AND PUNCTUAL <br /> SUPPLY FROM OUR SUB-SUPPLIERS OR SUBCONTRACTORS, AND CUMMINS RESERVES THE RIGHT TO MAKE PARTIAL <br /> DELIVERIES OR MODIFY ITS LABOUR OR SERVICE. WHILE CUMMINS SHALL MAKE EVERY COMMERCIALLY REASONABLE <br /> EFFORT TO MEET THE DELIVERY, SERVICE OR COMPLETION OBLIGATIONS SET FORTH HEREIN, SUCH DATES ARE <br /> SUBJECT TO CHANGE. <br /> INTERNATIONAL BUILDING CODE(IBC)CERTIFICATION <br /> The products in this quotation identified as meeting the requirements of the 2009 IBC have been certified by their respective <br /> manufactures via a combination of analytical testing and shaker table testing. Not all products have been shaker table tested. <br /> OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT(OSHPD) <br /> OSHPD seismic requirements are continuing to evolve. Please contact Cummins for the most current requirements for meeting <br /> OSHPD applications. <br /> SELECTIVE COORDINATION FOR NATIONAL ELECTRIC CODE(NEC)ARTICLE 700 AND 701 LOADS <br /> Cummins generators are equipped with the manufacturer's recommended circuit breaker. Information regarding this device can be <br /> supplied upon request.This quotation is not valid if any changes to this circuit breaker(s) is required to coordinate with other devices in <br /> the electrical distribution system. If changes are required,the customer must provide a copy of the coordination study listing the <br /> manufacturers part number of the disconnect device to be supplied with the generator and a revised quotation will be issued. <br /> TRANSFER SWITCH WITHSTAND AND CLOSE RATINGS <br /> Quotation: 0-129133-Q-07903 Doc Ref: Q-07903-20201026-0951 <br /> Page 6 of 11 <br />