My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 3RD FLOOR 2018-01-02 MF Import
>
Address Records
>
COLBY AVE
>
1321
>
3RD FLOOR
>
1321 COLBY AVE 3RD FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 8:23:14 AM
Creation date
1/14/2021 3:05:12 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
3RD FLOOR
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TRANSMITTAL <br /> tC4413ENCE EVERETT MEDICAL CENTER 9232002 <br /> ZIMMER GUNSUL FRASCA PARTNERSHIP <br /> ZGF PAW. k80467.04 IZ; ct.S 3 3 ems` <br /> .ra #(a06) 6a 3 <br /> 78G8 <br /> To:Tony Lee Ca YOIAQ "- J / <br /> Everett Public Works <br /> From: Russ Brown ZGF <br /> Via:Hand delivered <br /> RE: Plan Review Number B0206-002 P-itµ 4 "B 2-0G — e Z,-r- <br /> Providence Everett-Colby Campus Backfill <br /> In the course of demolition we have discovered unexpected conditions at the exterior walls of area C. <br /> In Area C at the exterior wall where we are adding a new window opening,we originally proposed the opening to be reinforced using an <br /> epoxy-carbon fiber reinforcing system. We have found that the interior face of the concrete wall is covered with a mop-on waterp oof <br /> membrane.Short of sand blasting the interior side of the wall we believe that there is no effective way to proceed with the carbon fiber <br /> reinforcing system.The hospital and the contractor feel that sand blasting will create dust and noise problems and have requested that we <br /> investigate an alternative method of reinforcing the wall. <br /> Attached is our Structural Engineer's proposed alternate method of reinforcing the wall at the opening.The new system uses 14"steel plates <br /> and Kwik-bolts. <br /> The sketch is stamped by the structural engineer.The Engineer is requesting that the new detail receive special inspection during construction. <br /> Please feel free to call or email me regarding the above. <br /> Ross Brown <br /> 206-521-3502 <br /> rbrowndgf.com <br /> 1%, <br /> ode <br /> 0 St? 2 41�'��1 <br /> G\�V OF S EA as <br /> PBt% <br /> CITY OF EVERETT IT <br /> REVIEWED FC)R PER <br /> q/a� .gz- <br />
The URL can be used to link to this page
Your browser does not support the video tag.