My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8417 EVERGREEN WAY Geotech Report 2022-10-25
>
Address Records
>
EVERGREEN WAY
>
8417
>
Geotech Report
>
8417 EVERGREEN WAY Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:40:18 PM
Creation date
1/28/2021 8:42:46 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8417
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Report- Revised lierracon <br /> Proposed CFT Retail Everett,Washington <br /> February 1, 2018 Terracon Project No. 81185002 <br /> Construction site safety is the sole responsibility of the contractor who controls the means, <br /> methods and sequencing of construction operations. Under no circumstances shall the <br /> information provided herein be interpreted to mean that Terracon is assuming any responsibility <br /> for construction site safety or the contractor's activities;such responsibility shall neither be implied <br /> nor inferred. <br /> 4.3 Foundations <br /> Our explorations encountered up to about 7 feet of previously placed, undocumented fill across <br /> the site. Due to the unpredictability of the existing fill, we recommend complete removal of existing <br /> fill below the proposed CFT Retail building and replacement with structural fill. If loose, materials <br /> are encountered at or below proposed footing depths during construction, those materials should <br /> also be removed and replaced with structural fill. The lateral extent of existing fill to be removed <br /> and replaced for the building pad should be at least two-thirds of the depth of excavation beyond <br /> the building pad footprint at the perimeter footing location. <br /> All overexcavated areas and excavations resulting from removal of the existing structures and fill <br /> should be backfilled with structural fill in accordance with the Earthwork section of this report. In <br /> our opinion, after these overexcavations are completed, the proposed buildings can be supported <br /> by a shallow, spread footing foundation system bearing on compacted structural fill extending to <br /> at least medium dense native soils. Design recommendations for shallow foundations for the <br /> proposed structures are presented in the following paragraphs. <br /> 4.3.1 Design Recommendations <br /> DESCRIPTION Column Wall <br /> Net allowable bearing pressure 2,500 psf 2,500 psf <br /> Minimum dimensions 24 inches 18 inches <br /> Minimum embedment below finished exterior 24 inches 18 inches <br /> grade for perimeter footings 2 <br /> Minimum embedment below finished floor 12 inches 12 inches <br /> grade for interior footings <br /> Approximate total settlement 3 <1 inch <1 inch <br /> <1/2 inch between <br /> Estimated differential settlement 3 <�/2 inch over 40 feet <br /> columns <br /> Ultimate coefficient of sliding friction 0.40 <br /> Responsive Resourceful Reliable 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.