Laserfiche WebLink
Geotechnical Engineering Report- Revised lferracon <br /> Proposed CFT Retail • Everett,Washington <br /> February 1, 2018 ■Terracon Project No. 81185002 <br /> Laboratory Testing <br /> As part of the testing program, all samples were examined in the laboratory by experienced <br /> personnel and classified in accordance with the attached General Notes and the Unified Soil <br /> Classification System based on the texture and plasticity of the soils. The group symbol for the <br /> Unified Soil Classification System is shown in the appropriate column on the boring logs and a <br /> brief description of the classification system is included with this report in the Appendix. <br /> At that time, the field descriptions were confirmed or modified as necessary and an applicable <br /> laboratory testing program was formulated to determine engineering properties of the subsurface <br /> materials. <br /> Laboratory tests were conducted on selected soil samples and the test results are presented in <br /> this appendix. The laboratory test results were used for the geotechnical engineering analyses, <br /> and the development of foundation and earthwork recommendations. Laboratory tests were <br /> performed in general accordance with the applicable ASTM, local, or other accepted standards. <br /> Selected soil samples obtained from the site were tested for the following engineering properties: <br /> ■ In-situ Water Content <br /> ■ Grain Size Distribution <br /> Responsive • Resourceful ■Reliable Exhibit B-1 <br />