My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 RIVERSIDE RD 2021-01-29
>
Address Records
>
RIVERSIDE RD
>
607
>
607 RIVERSIDE RD 2021-01-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2021 9:18:20 AM
Creation date
1/29/2021 8:05:12 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
607
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
449
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Marshal's Office at(360) 596-3900 or contact the Everett Fire Department at(425) 257-8124.) All such <br /> tests shall be witnessed by a Fire Department inspector. Call (425) 257-8124 or(425) 257-8120 to <br /> make an appointment for inspection. <br /> Contractors' materials and test certificates shall be submitted to the Everett Fire Department prior to <br /> issuance of any Certificates of Occupancy. <br /> Call (425) 257-8124 for more information. <br /> 41.The Snohomish County Emergency Radio System is employed by the City of Everett Fire Department <br /> emergency crews and operates at 800 MHz. Large metal-framed or metal and concrete buildings can <br /> weaken the signal so that communication and, therefore, firefighter safety is compromised. This <br /> structure must meet the requirements of EMC 16.03, Section 510,which specifically addresses required <br /> radio system performance standards in this structure. Your attention to this feature early in the planning <br /> stages will help avoid a costly, last-minute retroactive installation of radio signal amplification antennae <br /> and other equipment. For details, call the Everett Fire Department Plan Reviewer at(425) 257-8124. <br /> 42. Floors and sub-floors at or above grade in buildings (other than parking garages) shall be marked with <br /> numbers, in ascending order, beginning with the number"1" (for the ground floor or first floor), then"2", <br /> "3", etc. Letters shall be used only to designate specific areas as detailed below. <br /> Floors below grade in buildings (other than parking garages) shall be marked with the letter"B" (when <br /> there is only one floor below grade). When there is more than one floor below grade, they shall be <br /> marked with the letter"B"followed by numbers, in descending order, beginning with the number"1" (for <br /> the floor immediately below the ground floor or first floor), then "2", "3", etc. Example—"B1", "B2", "B3", <br /> in descending order. <br /> Mezzanines shall be marked with the letter"M". When there is more than one mezzanine, they shall be <br /> marked with the letter"M" followed by numbers, in ascending order. Example—"M1", "M2", etc. <br /> Parking garages shall use the letter"P"to designate floors. <br /> When there is only one parking level at or above grade, it shall be marked with the letter"P". When <br /> there is more than one parking level at or above grade, they shall be marked with the letter"P"followed <br /> by numbers, in ascending order. Example—"P1" "P2", etc. <br /> When there is only one parking level below grade, it shall be marked"P01". When there is more than <br /> one parking level below grade, they shall be marked with the letter"P" followed by numbers, in <br /> descending order. Example—"P01", "P02", etc. <br /> Large parking structures may use letters to designate columns for ease of locating automobiles. <br /> Example—"Floor P3, Column E". <br /> 43. Buildings containing high-piled combustible storage shall be in accordance with Chapter 32 of the 2012 <br /> IFC and NFPA 13. A Fire Department permit is required for high-piled storage. <br /> 44. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or closets with <br /> standard man door access. Locations shall be approved by the Fire Code Official (NFPA 13 8.16.4.1.3). <br /> 45. The location of Fire Department connections (FDC) and post indicator valves (PIV) shall be determined <br /> by the Fire Code Official. If immediate outside man door access is available to the sprinkler valves <br /> (risers), a PIV will not be required. Place at rear of building by the fire hydrant. <br /> 70 <br />
The URL can be used to link to this page
Your browser does not support the video tag.