Laserfiche WebLink
Appendix B-3 25-year and 100-year Rational Method Model <br /> Section Shape: Circular <br /> Uniform Flow Method: Manning's Coefficient: 0.0120 <br /> Routing Method: Muskingum-Cunge <br /> DnNode RDCO #7 UpNode RDCO#8 <br /> Material N-12 Size 8" Diam <br /> Ent Losses Groove End w/Headwall <br /> Length 139.0000 ft Slope 0.50% <br /> Up Invert 12.7600 ft Dn Invert 12.0650 ft <br /> Conduit Constraints <br /> Min Vel Max Vel Min Slope Max Slope Min Cover <br /> 2.00 ft/s 15.00 ft/s 0.50% 2.00% 3.00 ft <br /> Drop across MH 0.0000 ft Ex/Infil Rate 0.0000 in/hr <br /> Up Invert 12.0650 ft Dn Invert 12.7600 ft <br /> Match inverts. <br /> DnNode RDCO#7 UpNode RDCO#8 <br /> Record Id: RD9 <br /> Section Shape: Circular <br /> Uniform Flow Method: Manning's Coefficient: 0.0120 <br /> Routing Method: Muskingum-Cunge <br /> DnNode RDCB#2 UpNode RDCB#3 <br /> Material N-12 Size 12" Diam <br /> Ent Losses Groove End w/Headwall <br /> Length 394.0000 ft Slope 0.20% <br /> Up Invert 10.8200 ft Dn Invert 10.0320 ft <br /> Conduit Constraints <br /> Min Vel Max Vel Min Slope Max Slope Min Cover <br /> 2.00 ft/s 15.00 ft/s 0.50% 2.00% 3.00 ft <br /> Drop across MH 0.0000 ft Ex/Infil Rate 0.0000 in/hr <br /> Up Invert 10.0320 ft Dn Invert 10.8200 ft <br /> Match inverts. <br /> DnNode RDCB#2 UpNode RDCB#3 <br /> Record Id: SDI <br /> Section Shape: Circular <br /> Uniform Flow Method: Manning's Coefficient: 0.0120 <br /> „ , <br /> /7 <br />