1. Buildings that are equipped throughout with an approved automatic fire sprinkler <br /> system. <br /> 2. Common wall residential buildings that consist of four or fewer units,that do not <br /> exceed two stories in height, that are less than 5,000 square feet in area, and that have <br /> a one-hour fire-resistive occupancy separation between units. <br /> Q. Subsection 912.2 of the IFC, entitled "Location," is hereby deleted and the following inserted in its <br /> place: <br /> 912.2 Location. With respect to hydrants, driveways, buildings and landscaping, fire department <br /> connections shall be so located that fire apparatus and hose connected to supply the system will not <br /> obstruct access to the buildings for other fire apparatus. Unless otherwise approved by the fire code <br /> official, fire department connections shall be located more than 50 feet from a building to avoid any <br /> potential hazards to fire department personnel and equipment in the event of a fire.The location of fire <br /> department connections shall be approved by the fire code official. <br /> 16.03.100 Amendments to IFC Chapter 10, Means of Egress. <br /> Adopted as amended by Washington State with the following local amendments: <br /> A. Subsection 1004.10 of the IFC, entitled "Maximum occupant load," is hereby added: <br /> 1004.10 Maximum occupant load.The maximum number of occupants in an assembly occupancy as <br /> defined by this code may not exceed the occupant load determined in accordance with this section. <br /> 16.03.110 Amendments to IFC Chapter 11, Construction Requirements for Existing Buildings. <br /> A. Subsection 1103.5.3 of the IFC, entitled "Group 1-2, Condition 2," is hereby deleted and the <br /> following inserted in its place: <br /> 1103.5.3 Group 1-2, Condition 2. In additions to the requirements of Section 1103.5.2, existing buildings <br /> of Group 1-2, Condition 2 occupancy shall be equipped throughout with an approved automatic sprinkler <br /> system in accordance with Section 903.3.1.1.The automatic sprinkler system shall be installed as <br /> established by the adopting ordinance. Automatic sprinkler systems shall be installed no later than one <br /> years after the adoption of this section. <br /> 16.03.120 Amendments to IFC Chapter 12, Energy Systems. <br /> Adopted as amended by Washington State. <br /> 16.03.130 Amendments to IFC Chapter 20,Aviation Facilities. <br /> Adopted as amended by Washington State. <br /> 16.03.140 Amendments to IFC Chapter 21, Dry Cleaning. <br /> ra FIRE CODE ORDINANCE Page 20 of 39 <br />
The URL can be used to link to this page
Your browser does not support the video tag.