. � ( <br /> Plan Check No. C 57702 <br /> February 2, 1998 <br /> Page 4 of 6 <br /> 3! The handrail portion of the guardrail should be shown to be not less than 1 1/4 inches, nor more <br /> �� than 2 inches in cross-sectional dimension. The handrails shall be continuous the full length of <br /> the stairs and at least one handrail shall extend in the direction o: the stair run not less than 12 <br /> inches beyond the top riser nor less than a length equal to one tread depth plus 12 inches beyond <br /> the bottom riser. Ends shall be returned or shall terminate in newel posts or safety terminals. <br /> Section 1006.9 <br /> v'� It should be shown that the ex:erior exit doors have landings. The width of a landing should not <br /> be less than the width of the door it is serving. The length of the landing should not be less than <br /> 44 inches per Section 1004.10. <br /> 5 As the entry level is above the adjoining surface, the steps from the (anding down to the ground <br /> should be shown. If more than two risers are needed, handrails conforming to Section 1006.3 <br /> will be required. <br /> / <br /> .�6. It should be shown tha[ the stainvay shall have a landing at the bottom. The landing shall I�ave a <br /> dimension measured in the direction of travel not less than the width of the stainvay. Section <br /> 1006.7 <br /> �7.� The stair rise (4" minimum, 8" maximum) and run (9" niinimum) should be specified on the <br /> plans. Section 1006.3 <br /> `�8. The 2268 exterior door should bc specified to open to 180 degrees to prevent blockage of the <br /> conidor. Section 1005.4 <br /> Energy <br /> 1'' Lighting calculations are reyuired to show compliance. The included forms should be filled out � <br /> ' and retumed with the resubmittal. Note that exempt areas include areas specifically designed for <br /> medical patient procedures. Other spaces within the office such as corridors, reception rooms, <br /> restrooms and waiting rooms must comply. Section 1512.1 <br /> ��'lf. The R-30 insulation (9-10 inches thick) specified for the vaulted ceilings will not rypically fit in <br /> 2x10 construction and still allow for a 1" air space at the top. Manufacturer's specifications <br /> should be provided which shows the insulation to be no thicker than 8 3!8 inches thick. <br /> Accessibilitv <br /> ,.,1:" One accessib(e parking space is required. It should be van-accessible requiring an 8' wide space <br /> with an adjacent 8' wide access isle. Section 1107.2.2 <br /> l <br /> 2. The accessible parking space should be shown with a maximum 1:48 slope. Section 1107.2.4 <br />