My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1425 BROADWAY EVERETT BIRTH CENTER 2018-01-02 MF Import
>
Address Records
>
BROADWAY
>
1425
>
EVERETT BIRTH CENTER
>
1425 BROADWAY EVERETT BIRTH CENTER 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 9:20:55 AM
Creation date
2/17/2021 9:15:33 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
1425
Tenant Name
EVERETT BIRTH CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � ( <br /> Plan Check No. C 57702 <br /> February 2, 1998 <br /> Page 4 of 6 <br /> 3! The handrail portion of the guardrail should be shown to be not less than 1 1/4 inches, nor more <br /> �� than 2 inches in cross-sectional dimension. The handrails shall be continuous the full length of <br /> the stairs and at least one handrail shall extend in the direction o: the stair run not less than 12 <br /> inches beyond the top riser nor less than a length equal to one tread depth plus 12 inches beyond <br /> the bottom riser. Ends shall be returned or shall terminate in newel posts or safety terminals. <br /> Section 1006.9 <br /> v'� It should be shown that the ex:erior exit doors have landings. The width of a landing should not <br /> be less than the width of the door it is serving. The length of the landing should not be less than <br /> 44 inches per Section 1004.10. <br /> 5 As the entry level is above the adjoining surface, the steps from the (anding down to the ground <br /> should be shown. If more than two risers are needed, handrails conforming to Section 1006.3 <br /> will be required. <br /> / <br /> .�6. It should be shown tha[ the stainvay shall have a landing at the bottom. The landing shall I�ave a <br /> dimension measured in the direction of travel not less than the width of the stainvay. Section <br /> 1006.7 <br /> �7.� The stair rise (4" minimum, 8" maximum) and run (9" niinimum) should be specified on the <br /> plans. Section 1006.3 <br /> `�8. The 2268 exterior door should bc specified to open to 180 degrees to prevent blockage of the <br /> conidor. Section 1005.4 <br /> Energy <br /> 1'' Lighting calculations are reyuired to show compliance. The included forms should be filled out � <br /> ' and retumed with the resubmittal. Note that exempt areas include areas specifically designed for <br /> medical patient procedures. Other spaces within the office such as corridors, reception rooms, <br /> restrooms and waiting rooms must comply. Section 1512.1 <br /> ��'lf. The R-30 insulation (9-10 inches thick) specified for the vaulted ceilings will not rypically fit in <br /> 2x10 construction and still allow for a 1" air space at the top. Manufacturer's specifications <br /> should be provided which shows the insulation to be no thicker than 8 3!8 inches thick. <br /> Accessibilitv <br /> ,.,1:" One accessib(e parking space is required. It should be van-accessible requiring an 8' wide space <br /> with an adjacent 8' wide access isle. Section 1107.2.2 <br /> l <br /> 2. The accessible parking space should be shown with a maximum 1:48 slope. Section 1107.2.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.