My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3020 BROADWAY DINING ROOM 2018-01-02 MF Import
>
Address Records
>
BROADWAY
>
3020
>
DINING ROOM
>
3020 BROADWAY DINING ROOM 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 7:50:43 AM
Creation date
2/17/2021 10:37:29 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3020
Tenant Name
DINING ROOM
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P\V: :Auachcd lmagc I'acc I of 1 <br /> � <br /> Meg Haley <br /> From: E3ill Kingrey[Kingrey8@energy.v�su.eduj <br /> SenL• Wednesd2y, June 11, 2008 10:04 AM � � ` � �t ;S <br /> To: Meg H�ley <br /> Cc: Gary Nordeen; Linda Witham <br /> Subject: RE: Attached Image <br /> Dear Ms. Haley, <br /> Thanks for your quick response to my request. It appears tnat you intuition is correct- from wha; I see on the drawing this system <br /> will not tunction in eca�c�nizer mode because it has only one motorized damper which is �or.ated rr; the outside air plenum. <br /> �Vhen an airside economize�is used the system needs to provide up to 100% outside air-to do this with the system shown here, <br /> each of the return air ducts must be modulatcd closed with motorized dampers as the oulside air damper modulates open. As the <br /> outside temperature rises, more and more o�tside air is brought into the space to maintain the frst stage cooling set point Wher <br /> this happens, the air pressure in the space ri,es and it must be relieved to the outside through an opening to minimize pres;ure <br /> buildup. While the system has a relief air p!enum there is �o way to shut it off when the system is shutdown and it becomes <br /> a direct opening to the outside. - i.e. a hole in the wall. <br /> I would like to see the sequence of operation(SOP)for the fan coils and economizer just to make sure I'm not missing something <br /> shown eisewhere. this may be in the specification or on the drawings somewhere. <br /> Also Note 1 on the fan coil schedule should the following added: capabie of providing 100% outside air. <br /> I hope this helps wilh your review. <br /> \1'illi;nn Kingrcy. PI: I, <br /> Encrgy iinginccr <br /> �Vtil! lislcn;ion l:ncrv.�� Procr,un <br /> Phunc: l-3G0•95G-'II9 <br /> cmail: kiuercyUrrrcnrr��.��,u.cu� <br /> I(��r�• rndd�� Ilii� �rnidd�Ini�qtr,Prrau�r l h,��',• nnl (i��J flir hin�' l�r ntdkr i! �linrirr. � 7:Lii�r'Pd�r.il- <br /> From: Meg Haley [mailto:MHaley@ci.everett.wa.us] I <br /> SenY: Wednesday, ]une il, 2008 9:32 AM <br /> To: Bill Kingrey <br /> Subject: FW: Attached Image <br /> Mr. Kingrey, � <br /> This may help as weil...these are the schedules. <br /> =<0360 001.pdf» <br /> MP.��{LLLP.y NCARBIplansexaminer wwwevereltwa.orp�defauR.aspz71D=830 <br /> EM1'GIN£EHING/FUBLICS£RVICESDEPARTMENTI 3206 CEDAR SfREEf,SURE 200,EVEREIT WA 982011 425-257-8813 I FAX 425�257-8856 <br /> �n ti2oox <br />
The URL can be used to link to this page
Your browser does not support the video tag.