� <br /> Meg�Haley � l ��G�� �C� <br /> From: Meg Halzy <br /> Sent: Wednesday, June 25, 2008 5:11 PM <br /> To: 'Brenda McLeod'; 'jeffm@cnja.neP; Rick Robinson <br /> Cc: Tony Lee; 'Eric Sward' <br /> Subject: 3020 Broadway permit C0806-008 and field visit on Friday at 2pm <br /> Attachments: 0378_001.pdi <br /> Dear Brenda and JeN, <br /> Thank you Brenda for scheduling a field visit to determine the tenant improvements required to meet current code <br /> requirements for ex�++nq the dining room on the second floor. Assistant Fire Marshal Rick Robinson will also attend this <br /> site meeting, �t�vhich w�can discuss options and next steps for the issuance of this building permit. <br /> Attached are copies of the submiried plan and previously permitted plans of revisions to the dining/communiry area that I <br /> found in our microfiche files for reference. <br /> l:�*M <br /> D378_OOl.pdf(576 <br /> KB) <br /> In preparation for our field meeting on Friday at 2pm, I have listed some of our concerns: <br /> • Any area of the dining room that is less than 750 square feet or more than 49 people for unconcentrated assembly <br /> purposes, would require two exits, per IBC section 303.1. <br /> • Where two exits are required, they shouid be separated by at least one third the diagonal of the ioom area that they <br /> serve, per IBC section 10152.1 (2.). <br /> • Required exits should not pass :hrough kitchens, per IBC section 1014.2 (2.). <br /> • If the folding partitions can potentially create a room with less lhan two exits and an occupant load of more than 49, <br /> alterations will be required which wocid prevent ihis condition from occurring. <br /> • Doors from a space with more than 49 people should swing in the direction of exiting, per IBC 1006.1.2. <br /> • Doors opening into the path of egress travel should not reduce the required width �of the corridorJ by less than one-haif <br /> during the course of the swing, ore by more than 7 inches when fully open, per IBC section 10052. <br /> � No !ocks or latches are permiried on doors that are used for egress from rooms that have more than 49 peopie, <br /> unless panic hardware is provided, per I[3C section 1008.1.9. <br /> • Illuminated exit signs, tactile exit signs, means of egress illumination on backup power is required in rooms that have <br /> more 49 people, per IBC sections 1011.1 and 1006.3. <br /> Please let me know if you have any questions, and I look forward to meeting you on Friday. <br /> MP.�}{R.�pry NCAR81�.', . .. �rnn�,rr . �. .."�i .� . . <br /> ENG1NffRING/PUH.UCSERVICESDfPi�RTM£NTl 3.'07 C[DAR STRE[T,SUffE 200,EVERETT WA 98201 I 425-7A-8813: fN(425457�N856 <br /> � <br /> 1 I1 <br /> II <br /> � '� <br />