Laserfiche WebLink
Job Page <br /> mxTow Feely-BU#: 824022 1 of 10 • <br /> GPD Project Date <br /> 520 South Main Street Suite 2531 2019777.824022.02 07:53:12 06/20/19 <br /> Akron,Ohio 44311 Client Designed by <br /> Phone:(330)572-2100 Crown Castle <br /> FAX. (330)572-2101 msteward <br /> • <br /> Tower Input Data <br /> The tower is a monopole. <br /> This tower is designed using the TIA-222-H standard. <br /> The following design criteria apply: <br /> Tower is located in Snohomish County,Washington. <br /> Tower base elevation above sea level:394.00 ft. <br /> Basic wind speed of 110 mph. <br /> Risk Category II. <br /> Exposure Category C. <br /> Simplified Topographic Factor Procedure for wind speed-up calculations is used. <br /> Topographic Category: 1. <br /> Crest Height: 0.00 ft. <br /> Deflections calculated using a wind speed of 60 mph. <br /> CCISeismic Note:Seismic loads generated by CCISeismic 3.2.3. <br /> CCISeismic Note:Seismic calculations are in accordance with TIA-222-H. <br /> A non-linear(P-delta)analysis was used. <br /> Pressures are calculated at each section. <br /> Stress ratio used in pole design is 1.05. <br /> Tower analysis based on target reliabilities in accordance with Annex S. <br /> Load Modification Factors used:Kes(F,)=0.95,Kes(Ev,and Eh)= 1.0. <br /> Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not considered. <br /> Options <br /> Consider Moments-Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules <br /> Consider Moments-Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces <br /> Consider Moments-Diagonals J Assume Rigid Index Plate Ignore Redundant Members in FEA <br /> Use Moment Magnification 4 Use Clear Spans For Wind Area SR Leg Bolts Resist Compression <br /> Use Code Stress Ratios 'J Use Clear Spans For KL/r All Leg Panels Have Same Allowable <br /> 4 Use Code Safety Factors-Guys Retension Guys To Initial Tension Offset Girt At Foundation <br /> Escalate Ice 4 Bypass Mast Stability Checks 4 Consider Feed Line Torque <br /> Always Use Max Kz ' Use Azimuth Dish Coefficients Include Angle Block Shear Check <br /> Use Special Wind Profile 'J Project Wind Area of Appurt. Use TIA-222-H Bracing Resist.Exemption <br /> Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA 222 H Tension Splice Exemption <br /> Leg Bolts Are At Top Of Section Add IBC.6D+W Combination Poles <br /> Secondary Horizontal Braces Leg 'J Sort Capacity Reports By Component 4 Include Shear-Torsion Interaction <br /> Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow <br /> SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets <br /> SR Members Are Concentric Ignore KL/ry For 60 Deg.Angle Legs Pole Without Linear Attachments <br /> Pole With Shroud Or No Appurtenances <br /> Outside and Inside Corner Radii Are <br /> Known <br /> Tapered Pole Section Geometry <br /> Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade <br /> Length Length of Diameter Diameter Thickness Radius <br /> ft ft ft Sides in in in in <br /> Ll 60.00-31.75 28.25 4.25 16 19.6800 23.0600 0.1875 0.7500 A572-65 <br /> (65 ksi) <br /> L2 31.75-0.00 36.00 16 22.1765 26.5000 0.2188 0.8750 A572-65 <br /> (65 ksi) <br />