CONTRACTOR NOTES: STRUCTURAL STEEL NOTES: <br /> THE ARCHITECTS/ENGINEERS HAVE MADE EVERY EFFORT TO SET FORTH IN THE CONSTRUCTION AND <br /> CONTRACT DOCUMENTS THE COMPLETE SCOPE OF WORK.CONTRACTORS BIDDING THE JOB ARE 1. ALL STRUCTURAL STEEL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION <br /> NEVERTHELESS CAUTIONED THAT MINOR OMISSIONS OR ERRORS IN THE DRAWINGS AND OR OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION(AISC)"SPECIFICATION FOR THE DESIGN, AM <br /> SPECIFICATIONS SHALL NOT EXCUSE SAID CONTRACTOR FROM COMPLETING THE PROJECT AND FABRICATION,AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". O <br /> IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS.THE BIDDER SHALL BEAR THE <br /> RESPONSIBILITY OF NOTIFYING(IN WRITING)THE ARCHITECT/ENGINEER OF ANY CONFLICTS,ERRORS,OR 2. SUBMIT SHOP DRAWINGS OF ALL STRUCTURAL AND MISCELLANEOUS STEEL TO THE CONSULTANT <br /> OMISSIONS PRIOR TO THE SUBMISSION OF CONTRACTOR'S PROPOSAL.IN THE EVENT OF DISCREPANCIES FOR REVIEW&APPROVAL TO INCORPORATE ALL COMMENTS PRIOR TO FABRICATION.. <br /> THE CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK,UNLESS DIRECTED <br /> OTHERWISE. 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: <br /> -WIDE FLANGES ASTM A992,y=50 KSI <br /> -STRUCTURAL TUBING ASTM A500,fy=46 KSI ._ <br /> GENERAL NOTES: -PIPES ASTM A53,fy=35 KSI <br /> -PLATES,SHAPES,ANGLES AND RODS ASTM A36,fy=35 KSI <br /> DRAWINGS ARE NOT TO BE SCALED,WRITTEN DIMENSIONS TAKE PRECEDENCE,AND THIS SET OF PLANS -SPECIAL SHAPES AND PLATES ASTM A572,fy=42 KSI <br /> IS INTENDED TO BE USED FOR DIAGRAMMATIC PURPOSES ONLY,UNLESS NOTED OTHERWISE.THE -ANCHOR BOLTS ASTM A307 <br /> GENERAL CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE FURNISHING ALL MATERIALS,EQUIPMENT, 4:111daika <br /> LABOR,AND ANYTHING ELSE DEEMED NECESSARY TO COMPLETE INSTALLATIONS AS DESCRIBED 4. ALL BOLTS FOR STEEL TO STEEL CONNECTION SHALL BE SAE J429 GRADE 5,UNLESS SPECIFIED <br /> HEREIN. - OTHERWISE ON EQUIPMENT SUPPLIER DRAWINGS OR ON THESE DRAWINGS. <br /> PRIOR TO THE SUBMISSION OF BIDS,THE CONTRACTORS INVOLVED SHALL VISIT THE JOB SITE AND 5. ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND VERIZON WIRELESS STANDARDS,AND <br /> FAMILIARIZE THEMSELVES WITH ALL CONDITIONS AFFECTING THE NEW PROJECT,WITH THE SHALL BE PERFORMED BY JURISDICTION APPROVED CERTIFIED WELDERS USING E70XX <br /> CONSTRUCTION AND CONTRACT DOCUMENTS,FIELD CONDITIONS AND CONFIRM THAT THE PROJECT MAY ELECTRODES.ONLY PRE QUALIFIED WELDS(AS DEFINED BY VERIZON WIRELESS)SHALL BE USED. <br /> BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION.ANY ERRORS,OMISSIONS, WELDING OF GRADE 60 REINFORCING BARS(IF REQUIRED)SHALL BE PERFORMED USING LOW <br /> OR DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING. HYDROGEN ELECTRODES.WELDING OF GRADE 40 REINFORCING BARS(IF REQUIRED)SHALL BE <br /> PERFORMED USING E70XX ELECTRODES.WELDING WITHIN 4"OF COLD BENDS IN REINFORCING r <br /> THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH STEEL IS NOT PERMITTED. SEE FURTHER REINFORCING NOTE ON STRUCTURAL SHEETS FOR - <br /> V� <br /> CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT CLEARLY DEFINED BY THE CONSTRUCTION MATERIAL REQUIREMENTS OF WELDING BARS(IF UTILIZED ON THIS PROJECT). c <br /> HILL <br /> DRAWINGS/CONTRACT DOCUMENTS. professional services <br /> 6. ALL WEATHER EXPOSED STEEL AND HARDWARE SHALL BE HOT DIPPED GALVANIZED. <br /> THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN.THE CONTRACTOR FIELD MODIFIED STEEL AND HARDWARE SHALL RECEIVE(2)COATS OF ZINC ENRICHED PAINT. <br /> SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES 7. UNISTRUTS SHALL BE FORMED STEEL CHANNEL STRUT FRAMING AS MANUFACTURED BY <br /> AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. <br /> UNISTRUT CORP.OR APPROVED EQUAL.STRUT MEMBER SHALL BE 1%"x 1%",12 GA,UNLESS <br /> THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S/ OTHERWISE NOTED AND SHALL BE HOT-DIPPED GALVANIZED. N E W WAVE <br /> VENDOR'S SPECIFICATIONS UNLESS NOTED OTHERWISE OR WHERE LOCAL CODES OR ORDINANCES TAKEARCHITECTURE <br /> PRECEDENCE. 8. ALL WORK SHALL BE INSPECTED BY THE CONSTRUCTION MANAGER DURING AND AT COMPLETION <br /> OF CONSTRUCTION. SPECIAL INSPECTION SHALL BE REQUIRED ONLY WHEN ITS IS REQUIRED BY <br /> ALL WORK PERFORMED ON PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH THE JURISDICTION. <br /> ALL APPLICABLE CODES,REGULATIONS,AND ORDINANCES.CONTRACTOR SHALL GIVE ALL NOTICES AND 1133 164TH STREET SW <br /> COMPLY WITH ALL LAWS,ORDINANCES,RULES,REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC 9. THIRD PARTY SPECIAL INSPECTION IS REQUIRED FOR ALL HIGH STRENGTH BOLT(ASTM A325) SUITE 202 <br /> AUTHORITY,MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS,AND LOCAL AND STATE JURISDICTIONAL INSTALLATIONS AND FOR ALL FIELD WELDING(IF UTILIZED ON THIS PROJECT). LYNNWOOD,WA98087 <br /> CODES BEARING ON THE PERFORMANCE OF THE WORK. -HIGH STRENTH BOLTS(ASTM A325)WILL BE: -FIELD WELDING WILL BE: OFFICE:(425)778-3/300 <br /> 0 PROVIDED ON THIS PROJECT 0 PROVIDED ON THIS PROJECT JAYINENWAVEARCH.COM <br /> THE STRUCTURAL COMPONENTS OF THIS PROJECT SITE/FACILITY ARE NOT TO BE ALTERED BY THIS ®NOT PROVIDED ON THIS PROJECT ®NOT PROVIDED ON THIS PROJECT - <br /> CONSTRUCTION PROJECT UNLESS NOTED OTHERWISE. <br /> ANTENNA SUPPORTING POLE IS UNDER A SEPARATE CONTRACT.THE CONTRACTOR SHALL ASSIST DATE. 2-28-20 <br /> ANTENNA INSTALLATION SUB-CONTRACTOR IN TERMS OF COORDINATION AND SITE ACCESS.ERECTION PREPARED BY. YML <br /> SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION OF PERSONNEL AND PROPERTY FROM <br /> HAZARDOUS EXPOSURE TO OVERHEAD DANGERS. APPROVED BY. JYS <br /> GENERAL CONTRACTOR SHALL PROVIDE AT THE PROJECT SITE A FULL SET OF CONSTRUCTION <br /> DOCUMENTS UPDATED WITH THE LATEST REVISIONS AND ADDENDA OR CLARIFICATIONS FOR THE USE BY <br /> ALL PERSONNEL INVOLVED WITH THE PROJECT. SUBMITTALS <br /> NO DATE DESORPTION <br /> DETAILS INCLUDED HEREIN ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS <br /> MAY BE REQUIRED TO SUIT JOB CONDITIONS OR SITUATIONS,AND SUCH MODIFICATIONS SHALL BE <br /> INCLUDED AS PART OF THE SCOPE OF WORK. <br /> THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, <br /> EASEMENTS,PAVING,CURBING,ETC.DURING CONSTRUCTION UPON COMPLETION OF WORK. <br /> CONTRACTOR SHALL REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR <br /> ABOUT THE PROPERTY. <br /> 2-28-20 FINAL PERMIT <br /> CONTRACTOR SHALL ENSURE THE GENERAL WORK AREA IS KEPT CLEAN AND HAZARD FREE DURING 2-20-20 REVISED PERMIT <br /> CONSTRUCTION AND DISPOSE OF ALL DIRT,DEBRIS,RUBBISH AND REMOVE EQUIPMENT NOT SPECIFIED 2-19-20 REVISED PERMIT <br /> AS REMAINING ON THE PROPERTY,PREMISES SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM - 2-18-20 PRELIMINARY PERMIT <br /> PAINT SPOTS,DUST,OR SMUDGES OF ANY NATURE. <br /> THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES,REGULATIONS AND SAFETY <br /> REGULATIONS,ALL OSHA REGULATIONS,ALL PUBLIC AND MUNICIPAL AUTHORITIES,AND ANY UTILITY <br /> COMPANIES'REGULATIONS AND DIRECTIVES. <br /> THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OF WORK.EXACT A <br /> " <br /> DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD.THE CONTRACTOR IS TO VERIFY THE I! 2-28-2020 <br /> DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL DISCREPANCIES TO REPRESENTATIVE.ANY AY Y.= . <br /> MINOR ERRORS AND OMISSIONS IN THE DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE STA OF WASINGTON <br /> CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT <br /> OF THESE DOCUMENTS. <br /> CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS AND <br /> ELECTRICAL LINES AND ANTENNA MOUNTING. SITE <br /> VERIFICATION THAT EXISTING TOWER/POLE/STRUCTURE CAN SUPPORT THE PROPOSED ANTENNA,COAX SEA <br /> &ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. <br /> DT. EVERETT <br /> (MOD.SITE) <br /> 1321 COLBY AVE <br /> EVERETT,WA 98201 <br /> SHEET TITLE <br /> GENERAL NOTES <br /> SHEET NUMBER <br /> 1 GENERAL NOTES -- p - <br /> SP-1 <br />