Laserfiche WebLink
KEY NOTES' <br /> ANTENNA CABLE 1 <br /> O EXISTING ROOF RXO Y I TXO RX1 WEATHERPROOFINGIC <br /> - - <br /> ■ <br /> ■ KIT(TYP.) WEATHERPROOFING 21/2"0 MAX. •CABLE GROUND KIT O <br /> O EXISTING ANTENNA MOUNTING FRAME 0 JUMPER REQUIRED + + ;, KIT(SEE NOTE 3) - <br /> ONLY FOR 1 5/8"0 COAX `` • STANDARD GROUND <br /> O NEW ANTENNA/EQUIPMENT COR FOR ONNECTAON(TYP.) LSE OF � P. r l REFER TO NOTE. #6 AWG STRANDED . <br /> COPPER GROUND WIRE N <br /> EXISTING COLLECTION GROUND BAR AT EACH CONNECTOR i i EZ, ANTENNA CABLE IN (GROUNDED TO GROUND • <br /> 4 SECTOR,FILED VERIFY AND REPLACE WITH WEATHERPROOFING M' CABLE TRAY TO BAR)(SEE NOTE 1&2) �_ <br /> O LARGER ROUND BAR AS REQUIRED IF , I �� I �� I <br /> 1 <br /> INSUFFICIENT GROUND CONNECTION HOLES ` �,� KIT(TYP.) Pi :mail EQUIPMENTLOCATION <br /> illREFERTO NOTE2 (TYP.) CONNECTION OF COAX CABLE GROUND KIT <br /> IIMI <br /> EXISTING MASTER GROUND BAR.FINAL \ - TO ANTENNA CABLEOGROUND LEAD TO BLDG STEEL FRAMING ORCOLLECTIONGROUNDWATER MAIN C BAR MOUNTED <br /> FROMANTENNAFRAME41112 <br /> #6 A NEAR/BELOWANTENNA/EQUIPMENT GROUNDING,#2 AWG STRANDED ' OSUPPORTi�I�lANTENNA. <br /> OGREEN INSULATED COPPER CONDUCTOR REFER TO DETAIL 5, NOTES: 01111 <br /> CADWELD TO BOTTOM OF ANTENNA MOUNT TO J\ THIS SHT. 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS <br /> EXISTING COLLECTION GROUND BARt>.- n I •^\' DIRECT GROUND WIRE DOWN TO GROUND BAR. <br /> `7 #2 AWG STRANDED, 2. GROUNDING KIT SHALL BE ANDREW SUREGROUND TYPE KIT WITH <br /> T ' i FROM ANTENNA MAST AIR TERMINALS(WHEN #2 AWG STRANDED, <br /> INSULATED COPPER INSULATED COPPER <br /> CONDUCTOR BONDED TWO-HOLE LUG. <br /> REQUIRED) CONDUCTOR. TO GROUND WIRE 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT,COLD SHRINK SAVE '`L <br /> O <br /> ALONG CABLE TRAY TO SHALL NOT BE USED. ProfEsslo n al services <br /> 01• , , EXTERIOR GROUND BAR. <br /> GENERAL NOTES + 3 COAXIAL CABLE GROUND WIRE TO GROUND BAR CONNECTION <br /> • <br /> I 1. ALL CADWELD CONNECTIONS ON GALVANIZED NOT TO SCALE W a V E <br /> SURFACES SHALL BE CLEANED THOROUGHLY I ' // , ARCHITECTURE <br /> AND COVERED WITH TWO(2)COATS OF SHERWIN + I G V , COAXIAL CABLE GROUNDING COAXIAL CABLE GROUNDING <br /> WILLIAMS GALVANITE PAINT B350W3 OR EQUAL. v ! / I'jj , KITS WITH 2 HOLE KITS WITH 2 HOLE <br /> COMPRESSION LUGS(TYP.) COMPRESSION LUGS(TYP.) <br /> 2. ALL ELECTRICAL CADWELD AND MECHANICAL © _ LONG BARREL 1133 164TH STREET SW <br /> COMPRESSION LUGS WITH SUITE 202 <br /> GROUND CONNECTIONS WILL HAVE O il <br /> (2)5/16"BOLTS AND LOCK LONG BARREL COMPRESSION LUGS LVNNWOOD,WA 98087 <br /> NON-OXIDATION COMPOUND APPLIED TO v '_ • 0 I WASHERS WITH#2 AWG WITH(2)5/16"BOLTS AND LOCK OFFICE:OD,WA 98087 <br /> -3800 <br /> CONNECTION. ". \ RR�� INSULATED STRANDED WASHERS WITH#2 AWG INSULATED <br /> I I JAVRNEVWJAVEARCH.COM <br /> < + � JUMPER FROM WAVEGUIDE STRANDED JUMPER.SUPPLY AND <br /> 3. ANY METAL OBJECTS WITHIN 6 FEET OF THE ,,I•A' I,r - 0 PLATE. INSTALLED BY CONTRACTOR. <br /> EXTERNAL GROUND RING SHALL BE GROUNDED. \ `, 4"X 24"GALVANIZED STEEL <br /> BUSS BAR 4"X 12"GALVANIZED STEEL BUSS BAR DATE. 2-28-20 <br /> • • <br /> (PART#:BB- HOG-HDG-VZW, <br /> 4. ALL GROUNDING MATERIALS AND CADWELD „\ ri_II •\ 0 _ MFR BY ATC) (PART#:BB-412-HDG-VZW,MFR BY ATC) <br /> MOLDS,SHOTS,ETC.,SHALL BE FURNISHED AND I I ' #� n 03f8"TYP. - / 03/8"TYP. <br /> INSTALLED BY CONTRACTOR,UNLESS I"I _ f PREPARED BY. YML <br /> 03/8"X3/4"SLOT TYP. 03/8"X3/4"SLOT TYP. APPROVED BY. JYS <br /> OTHERWISE NOTED. �• ' - o0000000000 O O000000000o O <br /> 6•(/ <br /> OOOOOOOOOOc o 00000000000 <br /> 5. THE ELECTRICAL CONTRACTOR SHALL FOLLOW I I < ® 0 0 0 0 0 0 0 0 0 0 0 <br /> GROUNDING SYSTEM INSTALLED AND TESTING 000000000,00 <br /> PROCEDURES AS DESCRIBED IN THE GENERAL 4-�I * e Q p SUBMITTALS <br /> ELECTRICAL PROVISIONS. !J NO DATE DEBCRPTION <br /> • <br /> -- - LEGEND gk© J p <br /> a d UNIVERSAL BUSS BAR <br /> MOUNTING KIT \ 12_� <br /> ITEM DESCRIPTION W / 24'' (PART) <br /> PAR) :B T# B-HKU,MFR BY <br /> ATC5/8"DIAMETER x 10'-0"LONG COPPER CLAD UNIVERSAL BUSS BAR MOUNTING KIT <br /> ® GROUND ROD, MINIMUM 42"BELOW GRADE, #2/S AWG TINNED SOLID / 10 u.\\\\ (PART#:BB-HKU,MFR BY ATC) <br /> AT MINIMUM 10.-0"O.C.(HARGER#5810). BARE COPPER <br /> CONDUCTOR DOWNLEAD #2/0 AWG INSULATED STRANDED <br /> •--*--- NEW MECHANICAL CONNECTION CADWELD TO GROUND COPPER CONDUCTOR DOWNLEAD TO <br /> 2-28-20 FINAL PERMIT <br /> --.,.---- EXISTING MECHANICAL CONNECTION BAR WITH FINAL CADWELD MASTER GROUND BAR OR OTHER FINAL 2-20-20 REVISED PERMIT <br /> CONNECTION TO GROUND <br /> -11)- , ... ...m., <br /> RING GROUNDING POINT 2-79-20 REVISED PERMIT <br /> 2-18-20 PRELIMINARY PERMIT <br /> 1 GROUNDING PLAN AND NOTES NORTH 4 MASTER GROUND BAR 5 COLLECTION GROUND BAR <br /> SCALE. 3/8' -1'-0' (22x34), 3/18' - 1'-0' (11x17) NOT TO SCALE NOT TO SCALE 6....-;REGISTERED <br /> HITECT <br /> STRANDED CU WIRE WITH <br /> 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND 13.CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. GREEN,600V,THHN/THWN - <br /> j Will _. <br /> CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE INSULATION.SIZE AS --- AY Y.?O <br /> 2. ALL GROUNDING SHALL CONFORM TO THE CURRENT VERIZON WIRELESS STANDARDS. PERMITTED. SPECIFIED C STA OF WABFNOTON <br /> 3. CONDUIT ROUTINGS ARE SCHEMATIC.CONTRACTOR SHALL INSTALL CONDUITS SO THAT 14.USE OF 90°BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE PANI SCHEME SPECIFICATIONS: <br /> ACCESS TO EQUIPMENT IS NOT BLOCKED. AVOIDED WHEN 45°BENDS CAN BE ADEQUATELY SUPPORTED. <br /> 4. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND 15.GROUND RING SHALL BE LOCATED A MINIMUM OF 24"BELOW GRADE OR 6"MINIMUM PRODUCER(P) <br /> UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN BELOW THE FROST LINE. WIRELESS EQUIPMENT CABINETS,CABLE ENTRANCE <br /> CONNECTS TO WIRE <br /> BOLTED TO <br /> LUG, L <br /> THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. 16.INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF 1'-0"FROM TWO-HOLEGROUND BAR(WERE MAIN DISTRIBUTION FRAME GROUND BAR SITE <br /> 5. PREFABRICATED SHELTER WILL BE PROVIDED WITH INTERNAL WRING AND EQUIPMENT EQUIPMENT CONCRETE PAD,SPREAD FOOTING,OR FENCE. GROUND BAR USING 3/8"-16 <br /> INSTALLED.FOR COMPLETE INTERNAL WRING AND ARRANGEMENT REFER TO DRAWINGS 17.EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD x 1 1/4"STAINLESS STEEL - - - - (MDFB),AND STANDBY ENGINE-GENERATOR SET FRAME AND OTHER <br /> PROVIDED BY SHELTER MANUFACTURER. GALVANIZED SPRAY. HEX HEAD BOLTS AND NOISE PRODUCING EQUIPMENT SEA - <br /> 6. FOR INTERIOR EQUIPMENT LAYOUT AND LOCATION,SEE SHELTER MANUFACTURER'S 18.OBSERVE N.E.C.AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE HARDWARE. <br /> DRAWINGS AND SPECIFICATION.IN CASE OF CONFLICT THE DRAWINGS GOVERN. GROUNDING V \ ABSORBER(A) D T. E V ERE T T <br /> 7. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC(CADWELD). 19.GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S P• I N I CONNECTS TO THE EARTH ELECTRODE SYSTEM INCLUDING CENTRAL <br /> GROUND BAR ON WALL, O O O O O O OFFICE GROUND GRID,BUILDING STRUCTURAL GROUND,METALLIC <br /> 8. ALL GROUND CONNECTIONS ABOVE GRADE(INTERIOR&EXTERIOR)SHALL BE FORMED RECOMMENDATIONS OR AT GROUNDING POINTS PROVIDED(2 MINIMUM) O <br /> FLOOR OR ON ANTENNA WATER PIPE SYSTEM,ANTENNA SUPPORTING STRUCTURE GROUND <br /> USING TWO(2)HIGH PRESS CRIMPS. 20.MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 (MOD.SITE) <br /> TOWER \ © O O O O ,GAO O SYSTEM,AND ELECTRICAL SERVICE ENTRANCE GROUND <br /> 9. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP& OHMS. \ O O O O • `O 0 O 0 <br /> HAVE A VERTICAL SEPARATION OF 6"FOR EVERY ADDITIONAL CONNECTION. 21.MINIMUM BENDING RADIUS FOR GROUNDING CONDUCTORS IS 8"WHEN BENDING IS O O O}61 O NON-ISOLATED(N) 1321 COLEY AVE. <br /> 10.ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING NECESSARY.GROUND CONDUCTORS ARE TO BE AS STRAIGHT AS POSSIBLE. CAD WELD WITH#2/0 AWG ,%�i CONNECTS TO EQUIPMENT NOT IN AN ISOLATED GROUND ZONE(IGZ) EVERETT, WA 98201 <br /> SURFACES AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS.ALL EXTERIOR 22.NO SPLICES PERMITTED IN GROUND CONDUCTORS. <br /> ` \j i/; <br /> GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 23.ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SOLID TINNED BARE CU \t/ SUCH AS CBN EQUIPMENT FRAME GROUNDS AND DC GROUND <br /> 11.ALL EXTERIOR GROUND CONDUCTORS SHALL BE#2 AWG TIN PLATED COPPER UNLESS SPECIFIED VALUES. WIRE OR STRANDED CU CONDUCTORS FOR DC POWER SYSTEMS THAT SERVE CBN OR BOTH <br /> OTHERWISE INDICATED. 24.GROUND BARS SHALL NOT BE FIELD MODIFIED. WIRE WITH GREEN,600V, CBN AND IBN EQUIPMENT <br /> 12.GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD 25.ALL HORIZONTAL FENCE SECTIONS TO BE GROUNDED WITH 8"SINGLE BARREL TO N/TEN N INSULATION �. - SHEET TITLE <br /> STEEL,5/8"0 10-FT.LONG,AND SHALL BE DRIVEN VERTICALLY WITH THEIR GROUND STRAPS. TO ANTENNA STRUCTURE, ISOLATED(I) <br /> BUILDING,RING GROUND •GROUND BARS AT BOTTOM OF CONNECTS TO THE SINGLE POINT CONNECTION BAR(SPCB),FOR IBN <br /> TOPS 18"BELOW FINAL GRADE OR 6"BELOW FROST LINE FOR MAXIMUM DEPTH. 26.USE PANI SCHEME FOR LOADING ON MGB AS DISCUSSED IN NSTD 119,33&36. OR MGB - r TOWERS OR MONOPOLES SHALL - EQUIPMENT GROUNDING PLAN, <br /> USE EXOTHERMIC CONNECTION. DETAILS <br /> AND NOTES <br /> ----.) <br /> SHEET NUMBER ram <br /> 2 GENERAL NOTES 6 .GROUND BAR CONNECTION DETAIL AND NOTES G C_1 (/, � <br /> NOT TO SCALE `�/ <br />