Laserfiche WebLink
,_ <br /> 1 _ <br /> __ - — fg MAL ALL PEW RATIONS)) t 3" r <br /> y O 0 ® - FI <br /> PLASTIC TRIM CAP W/SCREW <br /> I _ L��.NIO SIGN FACE <br /> CONDUIT TO REMOTE POWER SOURCE <br /> (INSTALLER TO PROVIDE UL LISTED CONDUIT <br /> BY <br /> E�)E FD a &FITTINGS,AND MOUNTING HARDWARE) <br /> FRONT VIEW(w/FACE) h f^� 7T Q6ELJE�_Oa RACEWAY SERVICE COVER <br /> SCALE 1116 o J Ii `r4J L__RACEWAY <br /> all <br /> 7/ib"DIA MOUNTING MOLE(fYPJ 7/8"DIA ELECTRICAL INLET LED MODULE(fYP.ITOGGLE SWITCH �� <br /> (2)7/8"ELECTRICAL ROUTE HOLE ipill011111111.111111111 . <br /> POWER SUPPLY MOUNTED <br /> 4,66,./- <br /> • , O INSIDE RACEWAY <br /> yT 1 ) j11, (12)3/8"DIA.FASTENERS REQ'D <br /> PWR#1 _e (/'� N .i, O y" sa" .••" (TYPE LENGTH T.B.D.BY _ <br /> • Q INSTALLER ON SITE. <br /> • 4, <br /> PROVIDE BLOCKING,USE SLEEVES 1v. ai4 .0 <br /> _ LED MODULE ® �I <br /> WEEP HOLES W/UGMi BAFFLE - <br /> � . .� ,:� :� 9 WEEP HOLE(S) L LLM�.FL <br /> 3\/L- ,,� ( 9 W/ GN78AfFE <br /> PWR#2 f +�il / -�i ��i I I <br /> FRONT VIEW(w/o FACE) ill <br /> SCALE I:16 .�""' �C) <br /> "• 4,4,6,6 '^ a WALL FRAMINGPRIMARY LEADS BLACK,WHITE, (T.B.D.BY INSTALLER) <br /> rn <br /> 1/2"CONDUIT (I00-240 VAC)AND GREEN(GROUND)(TYP.) UL POWER SUPPLY ENCLOSER W/SWITCH <br /> (SUPPLIE BY EVERBRRE) NOTE:WALL STRUCTURE VARIES PER SITE. <br /> (UL APPROVED)(TYP.) Y INSTALLER(1 TO PROVIDE MOUNTING HARDWARE, IT IS THE INSTALLERS RESPONSIBRTIY TO <br /> I60WATT! ELUL USTEUSTED CONDUIT AND FITTINGS(TYP.) IDENTIFY CONDITIONS AND ADAPT TO <br /> 1/2"$TR.CONNECTOR / 160 WATTS! rr�a CD THESE VARIATIONS AS NEEDED <br /> (UL APPROVED)GYP.) J — <br /> TYPICAL 11TH WALL SECTION <br /> u b r e a k i I x a ±r ±r <br /> I o n l ELECTRICAL SPECS. SCALE 1:16 <br /> 42)ELECTRICAL <br /> AGILIGHT S12-60W-IOG27N <br /> 0 ,i„m= -0.80 AMPS EACH(INPUT) <br /> �®y TOTAL T.2OAMPS LR 120 V <br /> WIRING DIAGRAM USE O 20 AMP CIRcurc <br /> SCALE;NONE 'spy <br /> 3/8"DIAMETER FASTENER CHART <br /> WALL FASTENER COMMENTS EXAMPLE INSTALLATION INSTRUCTIONS <br /> CONSTRUCTION 1. OPEN PACKAGING CAREFULLY AND INSPECT FOR DAMAGE.IF DAMAGE IS FOUND,CLAIM • <br /> THRU BOLT WITH ANGLE OR USEAPA ENGINEERED WOOD ASSOCIATION FASTENER .s c` A' S-D <br /> c.� MUST BE FILED WITHIN AYS WITH SHIPPING AGENT. <br /> UNISTRUT ACROSS STUDS LOADS FOR PLYWOOD-BOLTS V 2. DETERMINE SIGN LOCATION AND TAPE UP THE TEMPLATE(IF PROVIDED)ON THE SURFACE TO <br /> MINIMUM 5/8"PLYWOOD WHICH IT WILL BE INSTALLED,RECEIVE CONFIRMATION FROM CUENT OR CONTRACTOR. <br /> WALL CONSTRUCTION 3. LAYOUT AND PRE.DRILL ALL MOUNTING AND ELECTRICAL HOLES REQUIRED FOR MOUNTING THE <br /> OFF LABEL USE,USE APA ENGINEERED WOOD RACEWAY/SIGN TO THE WALL LIBERTY TOGGLE BOLT <br /> ASSOCIATION FASTENER LOADS FOR PLYWOOD-BOLTS 4. PILL ALL HOLES WITH SIUCONE PRIOR TO MOUNTING THE LOGO. <br /> WOOD BLOCKING LAG BOLTS STEEP REDUCTION FOR COMBINER WITHDRAWLAND ��"�� GENERAL NOTES 5. ATTACH THE HORIZONTAL BLOCKING(IF REQUIRED)BEHIND WALL FRAMING SO ALL MOUNTING <br /> INSTALLER TO PROVIDE COMPLETION PHOTOS OF MOUNTING/CONNECTION POINTS,WIRE ROUTING POINTS HAVE SUPPORT, <br /> ATTACHED TO STUDS (3"EMBEDMENT INTO BLOCKING) LATERAL LOADS P'/AV4"i'U? AND OVERALL ELEVATION. 6. ALIGN LOGO TO MATCHING PRE-DRILLED HOLES WHILE INSERTING FASTENERS THROUGH,WALL <br /> SLEEVE FASTENER AND BLOCKING.FASTEN WITH HARDWARE.USE PVC SLEEVES TO PROTECT BUILDING FINISH <br /> (11/2"MINIMUM EMBEDMENT) SEE HILTI TECHNICAL GUIDE THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 SYSTEM OVER SHEATHING(IF NECESSARY). <br /> BRICK,CONCRETE BLOCK, OF THE NATIONAL ELECTRIC CODE AND/OR OTHER APPLICABLE LOCAL CODES,THIS INCLUDES 7. MAKE FINAL ELECTRICAL HOOK UP TO PRIMARY WIRING OF POWER SUPPUES THROUGH DRILLED <br /> SOLID CONCRETE PROPER GROUNDING AND BONDING OF THE SIGN. ELECTRICAL HOLES. <br /> HILTI HIT HY 20OR EQUAL SEE HILT)TECHNICAL GUIDE 8. TEST LIGHT FOR PROPER FUNCTION AND ILLUMINATION. <br /> " INSTALLER TO VERIFY SIGN G PROPERLY INSTALLED.CONNECTED AND GROUNDED. 9. PERFORM TOUCH-UP AS REQUIRED <br /> 10. CLEAN INSTALLATION WORK SITE OF ALL EXCESS MATERIALS AND DEBRIS.DO NOT DISCARD ANY <br /> NOTE:ALL FASTENERS TO BE THRU BOLTS IF POSSIBLE,USE ALTERNATE FASTENERS PER WALL TYPE SHOWN ABOVE IF THRU BOLTING IS NOT THIS DRAWING IS FOR INSTALLATION PURPOSES ONLY AND NOT TO BE USED FOR MANUFACTURING MATERIAL OR DEBRIS INTO ON SITE DUMPSTERS <br /> POSSIBLE.ALL FASTENERS ARE TO BE CHOSEN AND PLACED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br /> DRAWN BY SITE TITLE <br /> saa INSTALLATION DWP <br /> b 0000e d UBIF7304ADR-1 UBREAKIFIX <br /> • .•.oa Everbetle DRAWING DATE 06-02-20 7315 10TH ST.SOUTH EAST UBIF 181N LOGO2 ON RCWY <br /> 'D• o- 4949 SO.I TOTH ST. THESE DRAWINGS ARE THE EXCLUSIVE <br /> ••O • �o.• P.O.BOX20020 PROPERTY OFEVELBRITE.LLC.USE OF.OR CHECKED BY RHB LAKE STEVENS,WA 98258 PROJECT NO. DRAWING NO. REV <br /> pa.:00 e0. GREENFIELD,WI 53220 DUPLICATION IN ANY MANNER WITHOUT <br /> Aogq• I® 414-529-3500 EXPRESS WRITTEN PERMISSION OFEVERBRRE. A 06.02-20DWP RHB RELEASED FOR INSTALLATION DATE 06-02-20 SCALE AS SHOWN REF 430855 IN430855A A <br /> LLC IS STRICTLY PROHIBITED. REV DATE BY CHK DESCRIPTION <br /> /—r <br />