z '1111 Ill
<br /> COMMUNITY TRANSIT KASCH PARK 111111111"1i
<br /> w
<br /> REPAIRS AND IMPROVEMENTS PROJECT - 2019 Ii1►i�II
<br /> ROOF J11110"VICINITY MAP Permit#: B1903-012 O
<br /> Site Address: 2300 KASCH PARK RD BLDG A Q I���I
<br /> GENERAL PROJECT DESCRIPTION:
<br /> Owner: SNOHOMISH CO PUBLIC TRANS nz—
<br /> KP-A:Various flashing repairs and improvements of existing sheet metal roof. g o a
<br /> Tenant: COMMUNITY TRANSIT KP-C South Canopy:Installation of a new single ply recover roof,new prefinished Q LL; Z ^ 2 co
<br /> App. Date: 3/8/2019 sheet metal siding,and related flashing transitions. t--- N o - . o ,-----
<br /> it
<br /> '+` , A!RIrea Proposed Use: COMMERCIAL 4 r I KP-Fuel Island:Installation of a new single ply recover roof,new prefinished sheet C) a z Z cp
<br /> 01. I Description: FLASHING REPAIRS,REPAIRS TO SHEET . metal siding,and related flashing transitions. Z L ¢ a z N
<br /> i t . METAL ROOF �, KP-Vault Canopy:Installation of new prefinished sheet metal roof panels,and W a o
<br /> PROJECT s ` flf + ,e related flashing transitions. = Z o i d
<br /> SITE w tJllo,.;,, �e = Reviewed B Date#/�Q�r#s9 ®LDG - '' KP-Bus Wash:Various flashing repairs and improvements of existing sheet metal ^ o
<br /> /-� . roof. a o
<br /> ® '/ 11,tin.. , . , /Office Set Job Site Set Fire/Planning Set ,;..l,r- F � 1 1,' T
<br /> 1`I Raj',,.. s " , ,F , I -' , PHYSICAL ADDRESS N
<br /> ". ,i ., ,,
<br /> . t 2300 Kasch Park Road t_
<br /> \� Z d - Everett,Washington 98204 /1
<br /> s LX f fi; 1• t " .. W_
<br /> 0
<br /> r � O
<br /> •
<br /> �,f _ .r.., �� � � �' . 1 GENERAL NOTES
<br /> �` �" " , `�. , - 1.Contractor to verify all dimensions,appurtenances,and site conditions. Notify
<br /> • s i f _ ._ , concerned parties of any conditions prior to bid which would effect the indicated E
<br /> �•"' •"' ' �� mar x . work. Failure to notifyconstitutes acceptance of the conditions and indicated N
<br /> 'i , ,f scope of work.Existing conditions shall not be the basis for contract increases. O
<br /> CITY OF E V E R E T'T 2.Contractor shall not scale drawings,as the drawings are general;and are C)
<br /> Permit Services -� _ � intended to indicate the location of the proposed work. CD_
<br /> DRAWING INDEX BL G C
<br /> -" � � ��. 3.Details are included in this package. For conditions not detailed refer to the
<br /> SHEET NO. TITLE SHEET NO. TITLE
<br /> ._,.. ,., r specifications/drawings,NRCA and the manufacturers installation guidelines; �.
<br /> RO SITE PLAN 1 COVER PAGE Re BUS WASH ROOF PLAN � � whichever is more stringent shall govern. N ON
<br /> ...�
<br /> R1 ACCESS PLAN R7 CURB FLASHING DETAILS 4.Contractor shall coordinate the location of contractors equipment and vehicles N op
<br /> R2 BLDG.A ROOF PLAN R8 FLUID-APPLIED FLASHING DETAILS m r + '' with the Owner. Contractor shall not impede the Owners use of the premises. ILe ,C �`
<br /> R3 BLDG.C SOUTH CANOPY ROOF PLAN R9 BLDG.C SOtJTFfCATVOPY DETAILS' ', aK 5.All roofing related debris shall be picked up on a daily basis and legally disposed W - ce C
<br /> -Mr—BLDG.C SOUTH CANOPY ACM PLAN f�fi@---""PENETRATI8N-BE t:S'' — —BLD 1 of offsite. W w
<br /> `R '--"""°FUEL ISLAND ROOF PLAN R11 FUEL ISLAND�fETA1LS , . 6.Contractor shall maintain the operational status of all equipment,fans,vents,and = CD p� v CD
<br /> L.. C
<br /> -R4.4 FUEL ISLAND ACM PLAN R12 tAtiLT CANOPY' A& D SOUTH ' HVAC units duringthe course of the work. Contractor shall verify the status of �/) N :�
<br /> R6 VAULT CANOPY PLAN ST#i S�RUC "{"` "`"� _
<br /> all equipment prior to startup of the work. Failure to establish the operational c 5 6 cO
<br /> .-.*rq. status of the HVAC units and equipment shall not relieve the contractor of w O U 3 O
<br /> ABBREVIATIONS responsibility for non-operational HVAC equipment or units. O p }; N
<br /> SIM. SIMILAR N.I.C. NOT IN CONTRACT i'
<br /> M 7.Contractor shall be responsible for any damage to the structures and premises as 0 i U N co
<br /> TYP. TYPICAL S.S. STAINLESS STEEL f ` il a result of the execution of work. U cp i u_ 0 N �o
<br /> 8.Contractor shall verify the status of all roof drains and downspouts prior to startup CL M > O
<br /> UNO UNLESS NOTED OTHERWISE CONT. CONTINUOUS � � CV w N
<br /> O.C. ON CENTER MECH. MECHANICALLY of the work. Owners representative shall be notified of drain tests prior and be
<br /> MAX. MAXIMUM WI WITH
<br /> '"°` allowed an opportunity to observe said drain tests. Z N
<br /> MIN. MININMUM @ AT `�.„ ,' 4 k 9.The roof shall remain weather-tight during the course of roof work. Contractor w w
<br /> GALV. GALVANIZED RTW ROOF-TO-WALL R = =-= shall provide temporary weather protection capable of withstanding extended CL C Z UJ Z
<br /> (N) NEW INT. INTERIOR time periods on a daily basis. W w 0
<br /> (E) EXISTING EXT. EXTERIOR 10.A copy of the project plans and specifications shall be kept available on site at F= If— --' 0 _
<br /> MTL METAL
<br /> P.T. PRESSURE TREATED all times during the course of construction. U U <
<br /> 0/ OVER GA. GAUGE 11. Contractor shall abide by all Community Transit traffic requirements,including: PRJ# . 1 009-1 1 11
<br /> WRB WEATHER RESISTIVE BARRIER SAM SELF ADHERED MEMBRANE NORTH Speed Limit of 10mph on all property,following direction of travel as noted in the DR W : J J L
<br /> SITE PLAN I Access Plan,Sheet R1,and wearin high-visibility vests at all times on the C H K : MSC
<br /> THESE DENTS NAvE N0I 1EL�-1 CITY OF EVERETT DATE : 3/06/19
<br /> ��� DPP `'�:� �' , ' •E O VIE
<br /> r � ! ,� �M F 4� , FI WED FOR PERMjj - SHEET
<br /> NOT TO SCALE ye.. r ai -"'f,. ' IT /
<br /> PLUMBING PERMITS. ( /I' RO
<br /> rYIPVRIr3HT WFTHFRI-IOIT R.ASSOCIATFSNC 901R