TTLB10 <br /> <REF_usi= PANEL LOCATION: INSIDE CABINET ENCLOSURE 120/240` VOLT, 1 PHASE, 3 WIRE. <br /> -tscale: 1 _ AMP with ABBREVIATIONS: GENERAL NOTES <br /> iesolved A SERVING: STATION SHELTER 10,000 AIC, 70 MAIN BREAKER 1. PROVIDE 2"C FROM IT EQUIPMENT BOARD UNDERGROUND TO <br /> OFCI:OWNER FURNISHED CONTRACTOR INSTALLED <br /> fTAU< TELECOMMUNICATION SERVICE CONNECTION POINT.SEE CIVIL <br /> vasseal CKT LOAD DESCRIPTION TYPE KVA A/P PHASE A/P KVA TYPE LOAD DESCRIPTION CKT DRAWINGS C4 SERIES SHEETS FOR LOCATION AND ROUTE. <br /> fEL A264 04 001 RFCS:REGIONAL FARE COLLECTION SYSTEM <br /> 1 LIGHTING-ICONIC MARKER L 0.052 20/1 A 20/1 0.050 D ORCA SCANNERS 2 <br /> 3 LIGHTING-PLATFORM L 0.141 20/1 B 20/1 0.150 D RTPI DISPLAY 4 APTS:ADVANCED PUBLIC TRANSPORTATION SYSTEM 2. BRANCH CIRCUIT WIRING FROM PANEL A TO EQUIPMENT AND <br /> 5 LIGHTING-INFORMATION PANEL L 0.058 20/1 A 20/1 0.820 D IT EQUIPMENT& IT POWER STRIP 6 LIGHTING SHALL BE#12 COPPER INSTALLED IN CONDUIT.SEE <br /> 7 LIGHTING-POST LAMP L 0.030 20/1 B 20/1 0.250 D FUTURE CCTV POWER 8 <br /> RTPI:REAL-TIME PASSENGER INFORMATION SIGN PANEL SCHEDULE FOR CIRCUIT REQUIRMENTS. <br /> 9 TICKET VENDING MACHINE LEFT D 0.450 20/1 A 20/1 0.125 D PHOTO EYE&TIME CLOCK 10 GFCI:GROUND FAULT CIRCUIT INTERRUPT 3. TERMINATE CONDUITS AT UTILITY POINT TO COMPLY WITH <br /> 11 TICKET VENDING MACHINE RIGHT D 0.450 20/1 B 20/1 0.180 D GFCI RECEPTACLE 12 UTILITY DESIGN STANDARDS. $ <br /> oi <br /> PHASE LOAD PHASE A= 1.55 KVA, PHASE B= 1.20 KVA. 4. CONTROL CIRCUITS 1&3 BY LIGHTING CONTACTOR. <br /> 5. CONNECT LIGHTING CONTACTOR TO OPERATE BY PHOTO as` <br /> LOAD TYPE ELECTRIC CONTROL,CONNECTED IN SERIES WITH TIME SWITCH, " $ <br /> L R M H WH D A K LM TOTAL LOADS <br /> CONN.LOAD .281 2.48 2.76 KVA 13.25 AMP CONTACT#1.PARALLEL WITH KEY OPERATED OVERRIDE 8 <br /> SWITCH,MOUNTED UNDER INFO PANEL. <br /> COMPUTED LOAD .351 2.48 2.83 KVA 13.58 AMP <br /> 6. CONNECT CIRCUIT 7 TO OPERATE BY TIME SWITCH CONTACT a <br /> ❑ISOLATED GROUND BUS 0 FEED THRU LUGS ❑MAIN BKR SHUNT TRIP 0 PANEL SKIRTS g SURFACE #2.(CONTACTS 3&4 SPARE). <br /> d <br /> ❑RAINTIGHT NEMA-3R ENCLOSURE 0 DOUBLE LUGS Ig SERVICE ENTRANCE LABEL 0 INTEGRAL TVSS 0 FLUSH 7. PROVIDE NOISE FILTER AND INSTALL TO THE COIL OF EACH z <br /> REMARKS: DEFINITE PURPOSE CONTACTOR(2 PER TIME SWITCH). 4e.OAK/ <br /> 8. FURNISH AND INSTALL TRANSFORMERS AS SHOWN TO CONVERT 'ff__ , <br /> 120/240V POWER TO 12V AND 24V RESPECTIVELY TO STATION ID At;' ' i` <br /> PANEL LAMPS AND INFORMATION PANEL LIGHTING. !' <br /> * THE SERVICE CONNECTION(EXCEPTION)IS A 120/208(4 WIRE)AT THE FOLLOWING LOCATIONS: a,Rgo'sT��� <br /> • <br /> STATION roxnt <br /> 3026 WB 132ND ST SE/16TH AVE SE ()PHOTOELECTRIC TIME SWITCH SMAT <br /> 3045 EB 132ND ST SE/16TH AVE SE O <br /> NOISE FILTER(X2) CONTROL (ET904715 CR) CIRCUITINFORMATION <br /> (INTERMATIC ET-NF)� PANELNEEL LIGG HTING <br /> LIGHTING FIXTURE SCHEDULE** TS 24V CIRCUIT TO STATION (~ <br /> 4-POLE,20A IDENTIFIER PANEL <br /> I LIGHTING CONTACTOR 12V LAMPS D <br /> O <br /> UTILITY PANEL Ir <br /> ITEM DESCRIPTION LAMPS VA MOUNTING REMARKS TRANSFORMER METER A LC CIRCUITS TO LIGHT FIXTURES <br /> K KEY OPERATED OVERRIDE SWITCH.ATTACH TO Cl) <br /> - $LOAD CENTER ENCLOSURE EXTERIOR. Z <br /> 3 LED LIGHT BAR LED 100 INSIDE ICONIC MARKER 24V >CIRCUITS TO EQUIPMENT AND RECEPTACLES 0 <br /> o r, <br /> w 6 POST LAMP LED 15 SURFACE 2TOTAL v <br /> ROUTE UNDERGROUND TO UTILITY CONNECTION METER GROUNDED TO 7#8 BARE CU. 5/8"X8'GROUND RODS <br /> Z POINT.SEE CIVIL DRAWINGS 4 SERIES SHEETS Z <br /> 8 STATION IDENTIFIER LAMPS INCAND 2.5 SURFACE 6 TOTAL 12V / FOR LOCATION AND ROUTING STRUCTURE. O <br /> \ .. \ .• s._, 0 <br /> 4'LED ENCLOSED STATION ` P j <br /> a 9 LAMPS LED 47 SURFACE 3 TOTAL / <br /> — <br /> 3 INSIDE INFORMATION (3)#6,3"C PANEL GROUNDED TO 4::( <br /> 16 INFORMATION PANEL LIGHTS LED 14.4 4 TOTAL 24V <br /> PANEL STRUCTURE. - - <br /> ,7) "SEE SPECIFICATIONS FOR DETAILED INFORMATION(OWNER FURNISHED) (1)#10 INSULATED GROUND WIRE TO CD <br /> NETWORK INTERFACE DEVICE(NID)ON I <br /> g QTY OWNER FURNISHED CONTRACTOR EQUIPMENT MOUNTING PANEL. <br /> EQUIPMENT (PER POWER COMM CONTRACTOR FURNISHED& NOTES 0- Z <br /> STATION) INSTALLED INSTALLED*" C _ <br /> 'gCONTRACTOR TO CONNECT POWER.VENDOR WILL DO J <br /> g TICKET VENDING MACHINE(TVM) 2 X X �/ <br /> COMMISSIONING. PLATFORM EQUIPMENT & COMMUNICATION PLAN (TYPICAL) <br /> a STAND ALONE FAR TRANSACTION PROCESSOR 2 X X X CONTRACTOR TO CONNECT POWER AND COMM.VENDOR WILL DO N.T.S. > W Z <br /> E (SAFTP)OR CARD READER/ORCA SCANNER COMMISSIONING. ta W <br /> o REAL TIME PASSENGER INFORMATION(RTPI) PLAN NOTES oM <br /> o <br /> SIGNS(DOUBLE MOUNTED) 2 X X X c cr <br /> 0 1.IN SERVICE(4:45AM TO 12:45AM) /� <br /> o ICONIC MARKER LIGHTING 1 X X TIMESWITCH-OFF 1 HOUR AFTER SUNRISE AND ON 1 �f <br /> m HOUR BEFORE SUNSET <br /> POWER METER 1 X X <br /> 2.NO SERVICE(12:45AM TO 4:45AM) E I <br /> H POST LAMP 2 X X TIME SWITCH-ONLY EVERY OTHER STATION LAMP(2nd 0 =U <br /> "' STATION IDENTIFIER PANEL LAMP 6 X X AND 4th FROM ARRIVAL COLUMN)ON V CO <br /> a` STATION LAMP 4 X X 3.PHOTOCELL INSTALLED FOR FUTURE USE LLI <br /> BUT ELECTRICALLY DISCONNECTED AT THIS TIME 0 <br /> LOAD CENTER 1 X X Snohomish County Planning&Development Services <br /> INFORMATION PANEL 2 X X <br /> s ROUTER 1 X X X CRADLEPOINT COR 1BR650 APPROVED FOR CONSTRUCTION <br /> By: <br /> E SWITCH 1 X X X BLACKBOX LBH101A-H RIW Permit N0. ,--(9/1:11://) <br /> . HanmiGlobal Partner <br /> 25.mo CAT5e DISCONNECT PANEL 1 X X BLACKBOX JPM083A-R311241 Willows Road NE <br /> Date: to a <br /> I SURGE PROTECTOR 8 RECEPTICLE 1 X X a i( ) .. Phone:(425)822-4446 <br /> FAX:(425)827-9577 <br /> N 12V TRANSFORMER 1 X X INSTALL ONE T100 TRANSFORMER FOR STATION ID PANEL LAMPS www.otak.com <br /> INSTALL ONE TRANSFORMER FOR:THE INFORMATION PANEL 719 Second Ave,Suite 1250 32130T <br /> 24V TRANSFORMER 2 X X LIGHTS(INCLUDE ONE SPLITTER)AND ICONIC MARKER 111<8 Seattle,WA 98104 Project No. <br /> " x NETWORK VIDEO RECORDER 1 X X X POWER AND COMM FOR FUTURE INSTALLATION (206)382-9800 E 1 .02 <br /> www.dksassociates.com Drawing No. <br /> 2 - CONTRACTOR SHALL CONFIRM MAKE/MODELS WITH COMMUNITY TRANSIT IT DEPARTMENT PRIOR TO ORDERING EQUIPMENT. <br />