My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 RIVERSIDE RD COMPASS CANTEEN VENDING 2021-02-24
>
Address Records
>
RIVERSIDE RD
>
607
>
COMPASS CANTEEN VENDING
>
607 RIVERSIDE RD COMPASS CANTEEN VENDING 2021-02-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2021 1:44:20 PM
Creation date
2/24/2021 1:42:31 PM
Metadata
Fields
Template:
Address Document
Street Name
RIVERSIDE RD
Street Number
607
Tenant Name
COMPASS CANTEEN VENDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 411 <br /> A H B L <br /> October 8, 2019 <br /> Mr. Drew Martin, PE, SE <br /> Associate Engineer/Commercial Plans Examiner <br /> City of Everett Permit Services cm/Engitleers <br /> 3200 Cedar Street <br /> Everett, WA 98201-4516 <br /> ,Structural Engene.ers <br /> Project: Glacier Peak Compass TI, AHBL No. 2190664.20 Landscape A.r;i.Errs <br /> Subject: Response to Comments dated September 27, 2019 <br /> Plan Check Number: B1909-009, First Building Review <br /> Cpinalrinity Planners <br /> Dear Mr. Martin: <br /> Land u,veyarn <br /> This letter is in response to your comments dated September 27, 2019, regarding the above <br /> referenced project. The comments are included below(verbatim)for your reference. Our Neighbors <br /> responses are shown in bold after each comment. <br /> Structural <br /> 1. Sheet S1.1 shows modifications to the existing concrete tilt-up wall panels that include <br /> cutting new openings in the panels. The panels are the vertical lateral force resisting <br /> system (LFRS)for the building and have been designed as Special Reinforced Concrete <br /> Shear Walls using a response modification factoe of R=5.0 (i.e., bearing wall system per <br /> ASCE 7-10 Table 12.2-1 Item A.1). The following comments shall be addressed: <br /> a. Calculations substantiating the performance of the modified lateral force <br /> resisting system, and in particular the modified wall panels, shall be submitted <br /> for review per IEBC Section 807.5. Note that construction for this building is <br /> currently being performed under Permit No. B1801-035. The 10% DCR limit <br /> and reduced seismic loads per the exception shall not apply. See IEBC Section <br /> 807.2, IBC Sections 1604.1, 1604.4, and 1901.2, and ACI 318-14 Sections <br /> 18.10 and 18.11. <br /> Response: The original building was recently designed and constructed using the <br /> IBC 2015 and so the IBC was continued to be used for the attached calculation <br /> addendum. Existing wall panels are still well within acceptable loading for the <br /> original special concrete shear wall requirements. <br /> TACOMA <br /> • <br /> l� 2215 North 301h Street <br /> / / Suite 300 <br /> Tacoma,WA 98403-3350 <br /> 253.383.2422; . <br /> www,alibi,corn <br />
The URL can be used to link to this page
Your browser does not support the video tag.