Laserfiche WebLink
• 0 <br /> Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 mar 3 stories and all R1 Reused July 2016 <br /> Project Title: BERTCH CAPTIAL PARTNERS-COMPASS/CANTEEN Date 9/XX/2019 <br /> Calculation 0 0 Addition - 0 Addition For Building Department Use <br /> Area NOTE9 stand alone +existing <br /> O Spaces where<50%of . Spaces where z 50%of 0 <br /> luminaires are replaced luminaires are replaced <br /> LPA 0 Standard 0 Additional Efficiency Package Option 0 <br /> Calculation C406.3 Reduced Interior Lighting <br /> To comply vuth C406.3, the Proposed LPD shall be 25%lover than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE' <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> 101 Lobby:all other 9' 349 0.720 251 <br /> 102 Conference/meeting/multipurpose 9' 259 0.980 254 <br /> 103 Office:Enclosed 9' 185 0.890 165 <br /> 104 Office:Enclosed 9' 128 0.890 114 <br /> 105 Office:Enclosed 9' 128 0.890 114 <br /> 106 Electrical/mechanical 9' 79 0.760 60 <br /> 107 Lounge/breakroom:all other 9' 426 0.580 247 <br /> 108 Electrical/mechanical 9' 313 0.760 238 <br /> 109 Restroom:all other 9' 47 0.780 37 <br /> 110 Restroom:all other 9' 47 0.780 37 <br /> 111 Electrical/mechanical 9' 374 0.760 284 <br /> 112 Office:Enclosed 9' 104 0.890 93 <br /> 113 Office:Enclosed 9' 104 0.890 93 <br /> 114 Office:Enclosed 9' 104 0.890 93 <br /> 115 Office:Enclosed 9' 104 0.890 93 <br /> 116 Copy/print room 9' 96 0.580 56 <br /> 117 Office:Open plan 9' 360 0.780 281 <br /> 118 Office:Enclosed 9' 99 0.890 88 <br /> 119 Office:Enclosed 9' 99 0.890 88 <br /> 121 Restroom:all other 9' 47 0.780 37 <br /> 122 Restroom:all other 9' 47 0.780 37 <br /> 123 Corridor:all other 9' 527 0.530 279 <br /> Total Area 4026 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 3036 <br /> Proposed Lighting Wattage NOTE 3 <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,6,6 Fixtures Fixture NOTE 7 Proposed <br /> 2X4 51 41 2091 <br /> 1X8 4 30 120 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allov`ed Watts for Interior Lighting Total Proposed Watts 2211 <br /> Interior Lighting Power Allowance COMPLIES WITH C406.3 <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop dour;menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture, and ballast type(if included). <br />