Laserfiche WebLink
• • <br /> Page 11 of 11 December 26,2019 <br /> M2191213 Asbesto-Test,Inc.425-489-4040 <br /> House,Shop,and Shed(a,2401 Taylor Dr.,Everett, WA 98203 <br /> interior Features <br /> Bedroom information • Bonus Room on Lower Level <br /> • #of Bedrooms(Main):1 • Daylight Basement.Partially Finished Basement <br /> Bathroom Information Fireplace Information <br /> • #of Baths(Full):2 • U of Fireplaces:1 <br /> • €i of Baths(Total):2 • #of Fireplaces(Main):I <br /> • #of Main Baths(Full):2 Heating&Cooling <br /> Room information • Baseboard Heat <br /> • Kitchen with Eating Space on Main Level <br /> • Living Room on Main Level <br /> Samples taken are listed with their corresponding analyses.if asbestos is detected,those samples containing asbestos are listed first and noted with the <br /> initials"ACM". <br /> Some sample analyses listed may be a representative analysis of individual and separate samplings and analysis of homogenous materials,as prescribed <br /> byA.H.E.R.A.guideline. <br /> If,during demolition or renovation,any additional suspect asbestos containing materials are Idcated[may include but not limited to:sheet vinyl flooring, <br /> tile flooring,wall or ceiling texturings or paints,concrete siding or skirting,cement pipes,cement wallboard,electrical cloth,electrical wiring insulation, <br /> thermal paper,wallboard,joint compounds,vinyl wall coverings,spackling compounds,or any other suspect TS!(Thermal System Insulation)),those <br /> materials are presumed Asbestos Containing Materials unless determined to be non-asbestos by laboratory analysis. <br /> Asbesto-Test Inc.does not guarantee approximations of quantities of ACM,which may be listed with the analyses.It is therefore recommended <br /> professional abatement price and/or disposal quotes be obtained by inquiring as to fees per area of specific ACM material(Le.square or linear FT,etc.), <br /> or by on site assessment. <br /> Any and all materials identified as ACM and/or PACM in this report must be abated prior to disturbance in renovation or demolition. <br /> PLM(polarized light microscopy)has been known to miss asbestos in small percentages of some samples,which contain asbestos,thus negative PLM <br /> results cannot be guaranteed. Floor tiles and wipes should be tested with SEM(scanning electron microscope)or TEM(transmitting electron <br /> microscope),to insure analytical accuracy when asbestos is reported in small percentages <br /> Analytical test method:USEPA 600/R93/116**(PLM);WAC296-62-07753 App.! <br /> **One percent is the USEPA regulatory limit for asbestos in bulk samples. <br /> K, "FRIABLE'signifies'Easily Airborne" <br /> ACM signifies"Asbestos Containing Material" <br /> PACM signifies"Presumed Asbestos Containing Material" <br /> CAB signifies"Concrete Asbestos Board" <br /> • signifes"less than" <br /> TSI signifies"Thermal System Insulation" <br /> INAC signifies"Heating Ventilating AIr-Conditioning" <br /> NAD signifies"No Asbestos Detected" <br /> END OF REPORT <br /> ArLy <br /> Anal al Chem ,AIHA proficient <br /> !nap ct r, certified A.H.E.R.A. <br /> accr 174014; exp.July 17,2020 <br /> i 1 11 '. <br /> j BBB.1 B ,9ORM C ? <br /> /sma,1ua <br /> d_T <br /> 1429 Ave.D.#187,Snohomish,WA 98290 <br /> 425-489-4040;f 775-665-0420 <br /> www.asbesiolest cam'info@osMestoiesi.com <br />