Geotechnical Engineering Report <br /> Mixed-Use Everett <br /> 10521-19th Ave. SE <br /> Everett,Washington <br /> March 23, 2016 <br /> RN File No. 3109-001A <br /> Page 7 <br /> rest earth pressure can be calculated based on equivalent fluid density. Equivalent fluid <br /> densities for active and at-rest earth pressure of 35 pounds per cubic foot (pcf) and 55 pcf; <br /> respectively, may be used for design for a level backslope. These values assume that the on- <br /> site soils or imported granular fill are used for backfill, and that the wall backfill is drained. The <br /> preceding values do not include the effects of surcharges, such as those due to foundation <br /> loads or other surface loads. Surcharge effects should be considered where appropriate. <br /> Seismic lateral loads are a function of the site location, soil strength parameters and the peak <br /> horizontal ground acceleration (PGA)for a given return period. We used the US Geological <br /> Survey program "2008 PSH Deaggregation on NEHRP" to compute the PGA for the site. The 3- <br /> D histogram is included in Appendix A.The PGA for the active condition was reduced by one- <br /> half, referenced in Geotechnical Earthquake Engineering by Steve L Kramer, 1996. When <br /> considering seismic conditions, the above drained active and at-rest values should be increased <br /> as shown in the table below. H represents the wall height. <br /> Seismic Surcharge Loads <br /> Probability of Exceedance (Recurrence interval) <br /> 20% in 50 years (1 in 224 year) 10% in 50 years (1 in 475 year) <br /> Acceleration (g) 0.26 0.39 <br /> Active > 0.001 H 5H 8H <br /> Non-Yielding 5H 10H <br /> The above lateral pressures may be resisted by friction at the base of the wall and passive <br /> resistance against the foundation. A coefficient of friction of 0.5 may be used to determine the <br /> base friction in the native glacial soils. An equivalent fluid density of 300 pcf may be used for <br /> passive resistance design. To achieve this value of passive pressure, the foundations should be <br /> poured "neat" against the native dense soils, or compacted fill should be used as backfill <br /> against the front of the footing, and the soil in front of the wall should extend a horizontal <br /> distance at least equal to three times the foundation depth. A resistance factor of 0.67 has <br /> been applied to the passive pressure to account for required movements to generate these <br /> pressures. <br /> All wall backfill should be well compacted. Care should be taken to prevent the buildup of <br /> excess lateral soil pressures due to overcompaction of the wall backfill. Hand compaction <br /> equipment of a small roller should be used directly adjacent to the wall. <br /> Slabs-On-Grade <br /> Slab-on-grade areas should be prepared as recommended in the Site Preparation and Grading <br /> subsection: Slabs should be supported on medium dense or firmer native soils, or on structural <br /> fill extending to these soils. Where moisture control is a concern, we recommend that slabs be <br /> underlain by 6 inches of pea gravel for use as a capillary break. A suitable vapor barrier, such as <br /> Robinson Noble, Inc <br />