My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE Geotech Report 2022-10-25
>
Address Records
>
19TH AVE SE
>
10521
>
Geotech Report
>
10521 19TH AVE SE Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:43:53 PM
Creation date
2/26/2021 10:48:00 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Report <br /> Mixed-Use Everett <br /> 10521-19th Ave. SE <br /> Everett,Washington <br /> March 23, 2016 <br /> RN File No. 3109-001A <br /> Page 7 <br /> rest earth pressure can be calculated based on equivalent fluid density. Equivalent fluid <br /> densities for active and at-rest earth pressure of 35 pounds per cubic foot (pcf) and 55 pcf; <br /> respectively, may be used for design for a level backslope. These values assume that the on- <br /> site soils or imported granular fill are used for backfill, and that the wall backfill is drained. The <br /> preceding values do not include the effects of surcharges, such as those due to foundation <br /> loads or other surface loads. Surcharge effects should be considered where appropriate. <br /> Seismic lateral loads are a function of the site location, soil strength parameters and the peak <br /> horizontal ground acceleration (PGA)for a given return period. We used the US Geological <br /> Survey program "2008 PSH Deaggregation on NEHRP" to compute the PGA for the site. The 3- <br /> D histogram is included in Appendix A.The PGA for the active condition was reduced by one- <br /> half, referenced in Geotechnical Earthquake Engineering by Steve L Kramer, 1996. When <br /> considering seismic conditions, the above drained active and at-rest values should be increased <br /> as shown in the table below. H represents the wall height. <br /> Seismic Surcharge Loads <br /> Probability of Exceedance (Recurrence interval) <br /> 20% in 50 years (1 in 224 year) 10% in 50 years (1 in 475 year) <br /> Acceleration (g) 0.26 0.39 <br /> Active > 0.001 H 5H 8H <br /> Non-Yielding 5H 10H <br /> The above lateral pressures may be resisted by friction at the base of the wall and passive <br /> resistance against the foundation. A coefficient of friction of 0.5 may be used to determine the <br /> base friction in the native glacial soils. An equivalent fluid density of 300 pcf may be used for <br /> passive resistance design. To achieve this value of passive pressure, the foundations should be <br /> poured "neat" against the native dense soils, or compacted fill should be used as backfill <br /> against the front of the footing, and the soil in front of the wall should extend a horizontal <br /> distance at least equal to three times the foundation depth. A resistance factor of 0.67 has <br /> been applied to the passive pressure to account for required movements to generate these <br /> pressures. <br /> All wall backfill should be well compacted. Care should be taken to prevent the buildup of <br /> excess lateral soil pressures due to overcompaction of the wall backfill. Hand compaction <br /> equipment of a small roller should be used directly adjacent to the wall. <br /> Slabs-On-Grade <br /> Slab-on-grade areas should be prepared as recommended in the Site Preparation and Grading <br /> subsection: Slabs should be supported on medium dense or firmer native soils, or on structural <br /> fill extending to these soils. Where moisture control is a concern, we recommend that slabs be <br /> underlain by 6 inches of pea gravel for use as a capillary break. A suitable vapor barrier, such as <br /> Robinson Noble, Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.