Laserfiche WebLink
0 <br />PUBLIC WORKS <br />4. Ensure that full compaction can be achieved between the proposed sand filter <br />and detention pipes. Provide requirements for special compaction or <br />materials (CDF?) in the construction notes or details. <br />5. Show the footing drain in the applicable profile views. <br />6. City Standard drawing has been revised with minor changes, including <br />dropping the requirement for a sloped tank. Since the project application was <br />submitted prior to these changes the older design may be used, but the new <br />detail may also be used if desired. The project profile and WWHM modeling <br />should be updated if the design is changed. <br />• Sheet 6 — Road and Drainage Notes and Details <br />1. Provide the missing sand filter detail, and include sufficient detail on the <br />drawing and in the Drainage Report to demonstrate compliance with the <br />criteria for BMP T8.20. <br />2. Note the minor spelling error in the call -out for the manifold in Standard <br />Drawing 418: "48"-diameter manifold tees to be installed near end of each <br />pipe tow to provide..." <br />CPage <br />