My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE 2022-05-23
>
Address Records
>
19TH AVE SE
>
10521
>
10521 19TH AVE SE 2022-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2022 1:22:25 PM
Creation date
2/26/2021 2:35:12 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
412
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Building Permit Plark:4 Checklist, pg. 3 ENV-4 <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 <br /> Project Title: SILVER PLAZA RETAIL AND OFFICE SHELL Date <br /> Applicability Code Location in Build <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Departme <br /> In single story buildings,provide list of enclosed areas that exceed 2,500 <br /> sf,have ceiling height greater than 15 ft,and are space types required to <br /> comply with this provision.For each area identify space type,floor area, <br /> floor to ceiling height,and any exception taken; <br /> Spaces in single For each area provide calculations for percentage of conditioned floor area <br /> na C402.4.2 story buildings located within a daylight zone including skylight and eligible sidelight <br /> requiring skylights daylight zones; <br /> For each area provide calculations for percentage of skylight area,OR; <br /> Provide calculations for skylight effective aperture(Equation C4-5); <br /> Indicate haze factor of skylight glazing material or diffuser <br /> AIR LEAKAGE <br /> Indicate location of continuous air barrier on plans and sections; <br /> Air barrier <br /> yes C402.5.1.1 construction and Provide details for all joints,transitions in materials,penetrations in air <br /> sealing barrier and note method of sealing(caulked,gasketed,or other approved <br /> method) A500(pending) <br /> Rooms containing Indicate that room(s)containing non-direct vent appliances is isolated from <br /> open combustion inside the thermal envelope with a sealed air barrier, including doorway <br /> na C402.5.3 fuel burning gasketing and sealing around ductwork and piping penetrations; <br /> appliances used for Indicate insulation provided in wall,floor and ceiling of the room envelope, <br /> space conditioning and insulation required on combustion air ductwork <br /> Access openings Indicate locations of all access openings and doors to shafts,chutes, <br /> yes C402.5.4 and doors to shafts, stairways and elevators; stairs shown and <br /> chutes,stairways Indicate method of gasketing,weatherstripping and sealing of these doors located on <br /> and doors openings A121 <br /> Indicate locations of all stairway enclosure,elevator shaft and building <br /> Outdoor air intakes, pressurization relief openings,outside air intakes and exhaust openings; <br /> C402.5.5 <br /> es exhausts and relief <br /> y C403.2.4.3 Note in envelope plans that all relief,outside air intake and exhaust <br /> openings openings shall be provided with dampers in accordance with Mechanical Note 9 added to <br /> Section C403.2.4.3 sheet A121 <br /> Indicate method of sealing between light fixture housing and wall or ceiling; <br /> na C402.5.8 Recessed lighting in <br /> building envelope Note in envelope plans that all recessed lighting fixtures shall be IC rated <br /> and have an air leakage rating not greater than 2 cfm per ASTM E283 test; <br /> include these requirements in lighting fixture schedules <br /> na C402.5.6 Loading dock seals Indicate weather seal at cargo and loading dock doors <br /> Indicate locations and dimensions of vestibules and air curtains; <br /> Indicate exception and criteria utilized for all building entrances and exits vestibules 101 <br /> yes C402.5.7 Vestibules that do not have a vestibule or air curtain; EAST ENTRY and <br /> Indicate required performance for air curtains installed per exception 7; 100 WEST ENTRY <br /> For unconditioned vestibules,indicate which envelope assembly(interior are shown on <br /> or exterior)complies with the requirements for a conditioned space A121 <br /> Indicate on plans the air barrier boundaries and area calculations on all six <br /> sides of the air barrier; <br /> Indicate air barrier test method in accordance with ASTM E779 or <br /> approved equivalent; <br /> C103.2 Building air leakage <br /> Indicate required maximum leakage rate for compliance. <br /> yes <br /> C402.5.1.2 test Include the following requirements in project documents:(1)Submit air <br /> barrier test report to jurisdiction once test is completed;(2)If test results <br /> exceed 0.4 cfmlft2 at 0.3 in.wg,then visually inspect air barrier and seal <br /> noted sources of leakage;(3)Submit a follow-up report to jurisdiction <br /> noting corrective measures taken; (4)Include air barrier test report in <br /> compliance documentation provided to owner. A500(pending) <br /> If"no" is selected for any question, provide explanation: <br />
The URL can be used to link to this page
Your browser does not support the video tag.