Laserfiche WebLink
Silver Lake Plaza <br />Proposed Site <br />. On -Site Impervious area: <br />Proposed Commercial Roof = 9,300 sf. <br />Proposed Paving and Curbs=22,430 sf. <br />*Proposed Sidewalks and Stairs = 572 sf. <br />Total=32,302 sf. (0.742 Ac.) <br />*Note: Sidewalk and stair areas beneath roof overhangs are not calculated. <br />r7 <br />J <br />J <br />• <br />7 <br />Proposed Lawn and Landscaping = 8,597 sf. (0.197 Ac.) <br />All on -site disturbed pervious areas are to be compost/topsoil amended commercial <br />lawn/landscaping. => Pervious areas to be modeled as pasture per BMP T5.13. <br />Bypass Note: <br />Approximately 1,922 sf of area adjacent to the 19th Avenue right-of-way and along <br />the northern side of the new on -site building including bypasses the conveyance <br />system and on -site detention. Bypass area to consist of approximately 328 sf. of new <br />walkway area and 1,594 sf. of landscape area. <br />WESTERN ENGINEERS, INC. 16 PROJECT: 15-1415-A <br />