Laserfiche WebLink
• I <br /> From: Rick Hall <br /> Sent:Thursday, November 7,2019 10:48 AM <br /> To: David Swissa <br /> Subject:Dexter Water Use <br /> David, <br /> Below is an analysis done by one of my associates in California.This store had 43 washers,you only have <br /> 19 at this point.As you can see a 1%"incoming water line is more than sufficient. <br /> Best regards, <br /> Rick Hall <br /> Western State Design,Inc <br /> 14241 NE Woodinville Duvall Rd„. <br /> Woodinville, WA 98072 <br /> (425)214-4217 Direct <br /> (360)668-4747 Fax <br /> (4Z ). 170_pR2 Cell <br /> rhall@westernstatedesign.com <br /> www.westernstatedesign.com <br /> CONFIDENTIAL&PROPRIETARY INFORMATION <br /> This message is intended for the exclusive use of the addressee(s)and may contain information that is CONFIDENTIAL, <br /> PRIVILEGED and/or PROPRIETARY.If you are not the intended recipient(s),you are hereby notified that any disclosure,copying, <br /> dissemination or other use of this communication is prohibited. If you have received this communication in error,please <br /> delete/erase all copies of this message and its attachments and notify us immediately. <br /> Equipment Data: <br /> Model QTY Max GPM per Total Water Water per Max GPM Max GPM <br /> washer inlet per cycle fill (Total div Demand Demand <br /> valves (Washer fills by 3 fills per (The lower of <br /> 3X per cycle) max per fill or <br /> cycle) max per <br /> valves) <br /> Dexter 11 9 15.8 5.3 5.3 58.30 <br /> 20# <br /> Dexter 8 9 22.2 7.4 7.4 59.20 <br /> 30# <br /> Dexter 8 9 35.1 11.70 9 72 <br /> 40# <br /> Dexter 12 18 52.6 17.5 17.5 210 <br /> 60# <br /> Dexter 4 18 80.1 26.70 18 112 <br /> 90# <br /> Total 43 511.5 <br /> Industry Data: <br /> t z <br />