Saies
<br /> Service
<br /> NOTES AND EXCEPTIONS:
<br /> COVID 19 SUPPLEMENTAL STATEMENT
<br /> AS A RESULT OF THE OUTBREAK OF THE DISEASE COVID-19 ARISING FROM THE NOVEL CORONAVIRUS,TEMPORARY DELAYS IN
<br /> DELIVERY,LABOUR OR SERVICES FROM CUMMINS AND ITS SUB-SUPPLIERS OR SUBCONTRACTORS MAY OCCUR.AMONG OTHER
<br /> FACTORS,CUMMINS'DELIVERY OBLIGATIONS ARE SUBJECT TO CORRECT AND PUNCTUAL SUPPLY FROM OUR SUB-SUPPLIERS
<br /> OR SUBCONTRACTORS,AND CUMMINS RESERVES THE RIGHT TO MAKE PARTIAL DELIVERIES OR MODIFY ITS LABOUR OR
<br /> SERVICE.WHILE CUMMINS SHALL MAKE EVERY COMMERCIALLY REASONABLE EFFORT TO MEET THE DELIVERY,SERVICE OR
<br /> COMPLETION OBLIGATIONS SET FORTH HEREIN,SUCH DATES ARE SUBJECT TO CHANGE.
<br /> INTERNATIONAL BUILDING CODE(IBC)CERTIFICATION
<br /> The products in this quotation identified as meeting the requirements of the 2009 IBC have been certified by their respective
<br /> manufactures via a combination of analytical testing and shaker table testing.Not all products have been shaker table tested.
<br /> OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT(OSHPD)
<br /> OSHPD seismic requirements are continuing to evolve.Please contact Cummins for the most current requirements for meeting OSHPD
<br /> applications.
<br /> SELECTIVE COORDINATION FOR NATIONAL ELECTRIC CODE(NEC)ARTICLE 700 AND 701 LOADS
<br /> Cummins generators are equipped with the manufacturer's recommended circuit breaker.Information regarding this device can be
<br /> supplied upon request.This quotation is not valid if any changes to this circuit breaker(s)is required to coordinate with other devices
<br /> in the electrical distribution system.If changes are required,the customer must provide a copy of the coordination study listing the
<br /> manufacturers part number of the disconnect device to be supplied with the generator and a revised quotation will be issued.
<br /> TRANSFER SWITCH WITHSTAND AND CLOSE RATINGS
<br /> Transfer switch(es),if included in this quotation,require a withstand and closing rating(WCR)capable of meeting the available
<br /> upstream fault current(kAIC).The WCR may be based on a specific breaker rating or a time-based rating,and it is the responsibility of
<br /> a qualified facility designer or engineer to verify compatibility.In the event that the proposed transfer switch(es)are not compatible,
<br /> the transfer switch(es)will need to be re-quoted to ensure compatibility.A full listing of the WCR can be provided upon request and
<br /> will be included as part of the submittal package.
<br /> CUMMINS STANDARD EXCLUSIONS
<br /> Exhaust System
<br /> All off-engine piping,hangers,flanges,gaskets,bolts,insulation,other materials and labor to install.
<br /> Fuel System
<br /> All fuel piping and materials not limited to;supply,return,venting,valves,coolers,filters,pumps,fittings,primary fuel regulator,
<br /> storage tank&senders,external to genset package.All fuel for testing and initial fill.Fuel tank vent extensions and flame arrestors
<br /> unless specifically listed in the Bill of Materials.
<br /> Cooling System
<br /> Intake louvers,exhaust louvers,air dampers,sheet metal ducting,flex adapters,sound
<br /> attenuators/baffles.All off engine piping,flexible connections,labor and coolant for remote cooling systems.
<br /> Electrical
<br /> All off-engine wiring,field terminations of wiring,and lugs other than those detailed in our submittal.Mounting
<br /> Mounting bolts and anchors.Vibration isolators(if included)may be shipped loose for installation at the jobsite by others.Seismic
<br /> engineering calculations.
<br /> Electrical Testing
<br /> Not limited to International Electrical Testing Association(NETA),infrared scanning,harmonic content or other independent agency
<br /> testing of switchgear,switchboards,protective relays,circuit breaker,electrical coordination studies,arc flash studies and reactive load
<br /> site testing.
<br /> Environmental Testing
<br /> Environmental Protection Agency(EPA),local air quality district or other Authority Having Jurisdiction
<br /> (AHJ),including acoustical.
<br /> Programming
<br /> All protective relay settings,breaker settings,PLC programming or other user configurable device programming.
<br /> Documentation
<br /> Quotation:0-201287-0-21022 Doc Ref:0-21022-20210107-1449
<br /> Page 5 of 10
<br />
|