My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2131 LAKE HEIGHTS DR Plans 2022-12-27
>
Address Records
>
LAKE HEIGHTS DR
>
2131
>
Plans
>
2131 LAKE HEIGHTS DR Plans 2022-12-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2022 10:35:44 AM
Creation date
3/9/2021 2:53:55 PM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2131
Permit
M2010-107
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: M2010-107 <br /> Site Address: 2131 LAKE HEIGHTS DR <br /> Owner: BETHANY AT SILVER LAKE <br /> Tenant: [TenNamej <br /> App.Date: 10/31/2020 <br /> Proposed Use: COMMERCIAL ALTERATIONS <br /> Description: INSTALL TYPE I AND II HOODS <br /> Reviewed <br /> VECHA\ICAL DAWI \ SET TYPE 1 cc 2 COVNE�CIAL KITCHE\ HOOD A\ D SUPPLY AR i:OfficeBy V Date: I <br /> Set Job Site Set Fire/Planning Set <br /> SCOPE: <br /> CLASS I KEY NOTES: PROJECT: <br /> INSTALLATION OF TYPE I AND TYPE 2 EXHAUST BETHANY AT SILVER CREST A Project Management Company II <br /> SYSTEM,TEMPERED M.U.A.SYSTEM PER CAPTIVAIR 1 TYPE 1 DUCTS TO BE 16 GA.GALVANIZED OR 2131 LAKE HEIGHTS DR. 23444 30th Ave South, Suite 105, Kent Wa 98032 <br /> 18 GA.S/S ALL-WELDED,GREASE-TIGHT EVERETT WA.98208 R;7 2 DOCUMENTATION. CONSTRUCTION FOR EXHAUST. TYPE 2 HOOD SHALL BED'20 GAUGE, M.U.A.TO BE 20 GAUGE ALSOTYPE ONE AND TYPE 2 HOOD TO BE INSTALLED ON BLDG PERMIT #LEVEL ONE OF TWO STORY BUILDING. DUCTS TO 2 EXHAUST DUCTS SHALL SLOPE MIN.1/4"PER FOOT IN REVIEWk APPROVED <br /> RUN FROM HOOD OUT THE BACK WALL TO OF LINEAL LENGTH. DEC IJ APPROVED AS NOTED <br /> EXTERIOR OF BUILDING,THEN TO FANS ON BUILDING OWNER <br /> CONCRETE PAD. 3 ACCESSIBLE CLEANOUTS SHALL BE Bethany of the Northwest CITY'Ot rep n� RESUBMIT <br /> PROVIDED AT ALL 90 DEGREE ELBOWS AND 10'-0" Box 13700 Millcreek Pro �� � <br /> MINIMUM SPACING. Everett WA.98208 �.rt7,.• rig# e, COMPANY <br /> ALL HVAC,ELECTRICAL, PLUMBING,AND BY DATE <br /> CONSTRUCTION BY OTHERS PER STATE AND LOCAL 4 EXHAUST HOODS AND DUCTS TO HAVE <br /> CODES. MINIMUM CLEARANCE FROM COMBUSTIBLE SURFACES THIS DRAWING IS THE PROPERTY OF J&K CONSTRUCTION <br /> OF AT LEAST 18". OR FIRE WRAPPED WITH RATED R IS NOT TO BE USED OR REPRODUCED <br /> WITHOUT THE EXPRESSED WRITTEN CONSENT OF J&K CONSTRUCTION. <br /> MATERIAL. DIRECTORY <br /> Key Plan <br /> 1 COVER SHEET <br /> 5 EXHAUST OUTLETS TO BE MINIMUM OF 40"ABOVE <br /> 2 VICINITY MAP <br /> TOP OF ROOF SURFACE AND 10'-0"FROM ANY <br /> BUILDING AIR INTAKE. 3 FIRST FLOOR DUCT/FANS/HOODS. <br /> 4 ELEVATION OUTDOOR <br /> 6 GREASE DUCT TEST INCLUDING THE HOOD TO 5 ELEVATION INDOOR <br /> DUCT CONNECTIONS. PRIOR TO THE USE OR <br /> CONCEALMENT OF ANY PORTION OF THE GREASE <br /> DUCT SYSTEM,A LEAKAGE TEST SHALL BE <br /> PERFORMED. <br /> 7 PERFORMANCE,CAPTURE AND <br /> CONTAINMENT TEST REQUIRED. <br /> 8 GREASE DUCT TO EXHAUST FAN CITY OF EVERETT <br /> CONNECTIONS SHALL BE FLANGED AND GASKETED AT REVIEWED FI�W�� FOR PERMIT <br /> THE BASE OF THE EXHAUST FAN. <br /> 9 GREASE DUCT TO HOOD JOINTS SHALL BE MADE <br /> WITH CONTINUOUS INTERNAL AND EXTERNAL LIQUID <br /> TIGHT WELDED OR BRAZED JOINTS. <br /> 10 A WET CHEMICAL EXTINGUISHING SYSTEM WILL BE <br /> PROVIDED FOR ALL CLASS 1 HOODS AND WILL <br /> COMPLY TO THE IMC SEC.509.1,FIRE <br /> DEPARTMENT AND FIELD INSPECTION BY THE LOCAL <br /> JURISDICTION.FIRE EXTINGUISHING CONTRACTOR WILL <br /> PROVIDE DETAIL DRAWINGS AND <br /> SPECIFICATION TO LOCAL <br /> JURISDICTION FOR REVIEW. <br /> 11 GENERAL CONTRACTOR IS RESPONSIBLE FOR ° 1pL <br /> RATED DUCT SHAFT W/NON COMBUSTIBLE COVER SHEET <br /> MATERIAL FIRE RATED ENCLOSURE TO BE <br /> CONSTRUCTED TO LOCAL BUILDING CODES. (UNLESS BETHANY AT SILVERCREST <br /> FIRE WRAP IS INSTALLED) <br /> :.,a vmsw <br /> 12 DUCT HANGERS AND SUPPORTS PER <br /> SMACNA HVAC DUCT CONSTRUCTION STANDARDS. <br /> DIMMED SCAL <br /> VARIES <br /> ORM <br /> 1 OF 4 VID Mane, <br /> JASON <br /> Mnnm <br /> urz <br /> 9/30/20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.