My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2320 HEWITT AVE VERIZON WIRELESS ANTENNA 2021-04-01
>
Address Records
>
HEWITT AVE
>
2320
>
VERIZON WIRELESS ANTENNA
>
2320 HEWITT AVE VERIZON WIRELESS ANTENNA 2021-04-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2021 8:36:46 AM
Creation date
4/1/2021 8:35:47 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
2320
Tenant Name
VERIZON WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ ♦ <br /> 1. SIGNS & PLACEMENT M <br /> A. LOW LEVEL (BLUE) WARNING SIGNS — PLACE AT SITE ENTRY/ACCESS POINTS ONLY: V��nv <br /> 1. ROOF TOPS: PLACE SIGNS ON THE INSIDE OF ROOF HATCH; PLACE ON ACCESS DOOR UNLESS DOOR IS USED BY GENERAL PUBUC OR BUILDING TENANTS <br /> \ REGULARLY FOR ACCESS — IN THESE CASES CONSULT CONSTRUCTION MANAGER (CM) OR QUALITY CONTROL (QC) SUPERVISOR. <br /> 2. WATER TANKS: PLACE SIGNS ON COMPOUND GATE. THIS DRAWING WAS PREPARED SOLELY FOR THE USE <br /> 3. VERIZON—OWNED SITES: PLACE ONE SIGN ON SITE GATE. OF VERIZON WIRELESS AND MUST ONLY BE USED BY <br /> B. HIGH LEVEL (RED) WARNING SIGNS — PLACE AT ALL ANTENNA SECTORS WHERE ACCESS BY THE GENERAL PUBLIC TO THE ANTENNAS IS POSSIBLE: VERIZON WIRELESS EMPLOYEES,CCNTRACTORS,AND <br /> 1. ALL SIGNS WILL BE SECURED WITH EITHER STNNLESS STEEL ZIP TIES OR STAINLESS TECH SCREWS. VENDORS WHILE PERFORMING THE WORK SHOWN CN <br /> THIS CRAYONS.ANY OTHER USE OF THIS DRAWING IS <br /> 2. CONSTRUCTION COORDINATOR (CC) PARTICIPATION IN SIGN LOCATION. FORBIDDEN. <br /> A. CM WILL MEET WITH ALL CC'S TO OUTUNE CRITERIA FOR SIGN PLACEMENT; EMPHASIS WILL BE ON 'GRAY AREA' SITES, WHERE SIGN PLACEMENT IS PARTICULARLY <br /> CHALLENGING — WE WILL GIVE CC'S AS MUCH GUIDANCE ON SPECIFIC SITUATIONS AS WE CAN FORESEE, BUT CC'S WILL BE ENCOURAGED TO PARTNER CM OR QC IN Frei <br /> DECIDING PLACEMENT OF DIFFICULT SITES. A JOINT SITE VISIT MAY BE REQUIRED TO FULFILL REQUIREMENTS. <br /> B. CC WILL CALL OUT SIGN LOCATION(S) AT THE A&E WALK FOR EACH SITE AS THOSE OCCUR. <br /> C. ON SITES WITH EXISTING A&E BUT NOT YET CONSTRUCTED, CC WILL BE ASKED TO PROVIDE (WITHIN A REASONABLE TIME FRAME TBD) A DETAIL FOR SIGN PLACEMENT MORRISON HERSHFIELD <br /> n• THAT WILL BE SUP—SHEETED INTO EXISTING SETS. <br /> IN CASE OF EMERGENCY CALL: aO 3. SIGNAGE SHALL NOT EXCEED 3 SF IN AREA. 600 STEWART STREET,SUITE 200 <br /> SEAT LE,WA 98101 <br /> PHONE:208.268.7370 <br /> 1-800-264-6620 ESPROOM6 FCC SIGN NOTE; www.monisonhershfieid.com <br /> DO NOT SCALE DRAWINGS. CONTRACTOR MUST <br /> COORDINATE WITH TOWER OWNER IF FCC SIGN IS NOT PRESENT RED IN VERIFY ALL DMENSIONS AND ADVISE CONSULTANTS <br /> SITE NAME COLOR W/SIGN TO ETEXT& MODIFICATIONS ANY ORS O WORK <br /> J SHO SHOWN SHALLS BEC <br /> SITE# TBD BORDER IN WHITE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL <br /> STATE: TBD VIOLATORS ALL PREVIOUS ISSUES OF THIS DRAWING ARE <br /> WILL BE SUPERCEDED BY THE LATEST REVISION. ALL <br /> SWITCH: TBD DRAWINGS AND SPECIFICATIONS REMAIN THE <br /> PROPERTY OF MORRISON HERSHFIELD <br /> FCC CALL SIGN# TB p PROSECUTED CORPORATION. <br /> O GENERAL SIGN P TO BE DETERMINED ONO TRESPASSING SIGN <br /> PRIOR TO SIGNSSBEINGGMADE <br /> Z <br /> 111111111)11/ m <br /> LLI <br /> C Q <br /> \ u �o o E <br /> O N Q 6N <br /> NOTICE o \ N o= 1 <br /> Go*) SIGN TO BE WHfTE IN \ •— •� UU W 7 COLOR W/ RED ILAI \ LJN an W' ' CA U T I 0 N VERIZON WIRELESS oi. w w <br /> FCC Registration #: — — GENERATOR ROOM W <br /> gO � w <br /> • This room contains energized battery to <br /> Beyond this point you are entering an TBD systems. �.. I-11 <br /> area where RF Emissions may exceedT W <br /> e FCC General Population Exposure • electrical room eocuits.s energized O©�O <br /> I <br /> Limits 0 o circuits. <br /> Flow all pinged ism•na>tB gWJeF,os . • The battery electrolyte solutions are p© <br /> .w Ha in en Rren.,rmen, a TBD TO BE DETERMINED corrosive liquids..-...„,,,., .,--._ PRIOR TO SIGNS BEING MADE —yp� — —r rT1 <br /> ORF SIGN CD FCC SIGN O CAUTION BATTERY SIGN <br /> 3 (SEE NOTE) REV I DESCRIPTION I DATE <br /> j� �4 A !ISSUED FOR e0%SMITTAL i 08.292017 <br /> B :RNSSUED FOR 9016SUBMITTAL i 11.222017 <br /> \ C ISSUED FOR 100%EDSBUBMRTAL 01.052018 <br /> / 11 <br /> VERIZON <br /> WIRELESS a ISSUED FOR PERMIT I 0207.2018 <br /> /`\ \ i <br /> ,ram \ EQUIPMENT <br /> ROOM <br /> NETWORK COMPLIANCE SUBMITTALS I DATEPREDMINARY SUBMISSION <br /> ACAUTION r©r30%SUBMISSION <br /> O O 60%SUeM651ON <br /> O I I ��� I • - -= I - <br /> . 90%S SUBMISSION <br /> 1132.101] <br /> /F{ 100%SUBMISSKw 01.052018 <br /> \'I L ORIGNAL ISSUE <br /> ISSUED FOR CONSTRUCTION <br /> / ISSUED FOR PERMIT I 02072018 <br /> Authorized rDANGE: ] <br /> RECORD SET(NSSULTS) I <br /> 00 PROJECT STAMP ' <br /> Corrosive Personnel DIESEL FUEL X 7170182 8259 REGISTERED <br /> material. NO SMOKING DEDONE BY: ARCHITECT <br /> Avoid contact with 0 <br /> N LV DESIGNED FA ' - <br /> eyes and skin. NO OPEN FLAMES DRAWNBS LP -� <br /> CHECKED BY: RL 1 -- .-. <br /> ._. ^pro ~<-� �.. COPYRIGHT` 1�A E0 'SHINGTON <br /> OCORROSIVE MATERIAL O AUTHORIZED PERSONNEL O DIESEL HAZARD _ SHEET TITLE <br /> DETAILS <br /> SIGN LOCATION PLAN � O SIGNAGE <br /> NORTH <br /> N.T.S. SIGNAGE DETAILS 1 SHEET NJMBER A512 <br />
The URL can be used to link to this page
Your browser does not support the video tag.