GROUNDING REFERENCE NOTES verizonv <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br /> THIS DRAWING WAS PREPARED SOLELY FOR THE USE <br /> ® BOND COMMUNICATIONS EQUIPMENT FRAME GROUNDS TO 'I' SECTION OF MGB ® COPPER GROUND ROD ® TEST WELL OF VFR¢ON WRELESS AND MUST ONLY BE USED BY <br /> WITH (1) STRANDED GREEN INSULATED #2/0 AWG COPPER WIRE. SUPPORT VER¢ON WRELESS EMPLOYEES,CONTRACTORS,AND <br /> FROM CABLE RACK SIDE BAR USING INSULATED STANDOFF HARDWARE. , CONNECT PER <br /> MANUFACTURER SPECS T_ GROUND BAR VENDORS WHILE PERFORMING THE WORK SHOWN ON <br /> THIS DRAWING.ANY OTHER USE OF THIS DRAWING IS <br /> ® GROUNDING OF ELECTRICAL SERVICE EQUIPMENT SHOULD BE AS PER NEC, • CAOWElD CONNECTION FORBIDDEN. <br /> MUNICIPAL AND UTILITY CO. REQUIREMENTS. <br /> • MECHANICAL CONNECTION <br /> OBOND COMMUNICATIONS EQUIPMENT FRAMES TO /2/0 AWG INSULATED GREEN (DOUBLE HOLE LUG) <br /> COPPER WIRE WITH (1)/6 ANC INSULATED GREEN COPPER WIRE. n <br /> FIELD VERIFY h TIE INTO EXISTING GROUNDING ST1tA1 <br /> ® NEW MIN. 1/4'x4'x24'TINNED COPPER 1AAa LLH GROUND BAR (MOB). ENSURE MORRISON HERSHFIELD <br /> THERE IS ENOUGH SPACE FOR ALL CONNECTIONS. OVERALL LENGTH SHALL <br /> ALLOW FOR 10S SPARE FUTURE TERMINATIONS. STACKING IS NOT PERMII ILL). <br /> 600 STEWART STREET,SUITE 200 <br /> ® BOND MASILX GROUND BAR (MOB)TO NEW EXTERIOR GROUND RING WITH (2) SEATTLE,WA PHONE:2062688370 <br /> /2 AWG SOLID TINNED COPPER CONDUCTORS. <br /> W W W.monisonhershfield.com <br /> ® BOND ALL METAWC ENCLOSURE PANELS, EQUIPMENT, GRILLS, AND ANY !!`. <br /> MISCELLANEOUS METAL IN THE EQUIPMENT ROOM TO THE HALO GROUND LOOP V/ DO NOT <br /> WITH A#6 AWG INSULATED GREEN COPPER WIRE. VERIFY AU_ DONS AND ADVEERACTOR CONSULTANTS <br /> O BOND DOORS AND DOOR FRAMES IN THE EQUIPMENT ROOM TO THE HALO OF ANY ERRORS OR OMISSIONS.NO VARIATIONSULTA OR <br /> BE <br /> GROUND LOOP. ® MODIFICATIONS TO WORK SHOWN SHALL BE <br /> ® BOND CABLE RACK AT ALL JOINT AND CORNER LOCATIONS. V� ` IMPLEMENTEDLPREVIOUS <br /> MSS WITHOUT POOR WRITTEN WING APPROVAL <br /> ALL PREVIOUS ISSUES OF THIS ORAWNG ARE <br /> --- ---- - -_------------------------------ SUPERCEOED BY THE LATEST REVISION. ALL <br /> ® BOND CABLE RACK IN TWO OPPOSITE LOCATIONS TO THE HALO GROUND LOOP. © ® PROPERTY DRAWNGS MO <br /> SPECIFICATIONSMC RRLSON RHAAIN THE <br /> ERSHFIELD <br /> 1 Q NEW TELCO GROUND BAR MOUNTED ON TELCO BACKBOARD. 1 '4� <br /> f• Q CORPORATION. <br /> • <br /> BOND TELCO GROUND BAR TO MASTER GROUND BAR WITH A#2 AWG 1 \ 17 ---- - <br /> STRANDED GREEN JACKET COPPER CONDUCTOR. I •. M <br /> 2 GROUND ALL EXTERIOR EXPOSED METAL OBJECTS. USE TWO HOLE LUGS FOR _J I • U _-—--—--—--—_-—--—-- , I <br /> CONNECTION TO FLAT METAL SURFACES. USE ONLY STAINLESS STEEL HARDWARE 1 -- --—--—-- <br /> ON ALL MECHANICAL CONNECTIONS. APPLY ANTI-OXIDIZING COMPOUND TO ALL <br /> LUGGED CONNECTIONS. STRIP PAINTED SURFACES PRIOR TO MAKING GROUND I �~ <br /> CONNECTIONS.APPLY GRAY ZINC RICH PAINT (COLD GALV.)TO ANY METAL <br /> EXPOSED BY STRIPPING, GRINDING, CUTTING OR DRILLING. \ I PACKAGED w <br /> I O I Z <br /> �3 PROVIDE SECONDARY GROUND RING BOND BY SHELTER DOWNLEAD CONDUCTOR AO-1 II co O <br /> FROM INTERIOR GROUND RING (HALO) TO THE EXTERIOR GROUND RING. I I _ <br /> v <br /> EXOTHERMIC WELD CONNECTION TO GROUND RING.TYPICAL IN ALL FOUR (4) \ I ��-� I _ co J <br /> CORNERS OF HALO. f 1 ' 1. -- __ ]_L__ __ �__ 1 ., Q <br /> 4 PROVIDE A GROUND RING BURIED 30' BELOW GRADE OR FROST UNE, \ T2 1I 1 �= "� I O v o0 E <br /> WHICHEVER IS DEEPER. THE GROUND RING SHALL BE INSTALLED 2'-0'AWAY I II Lu N Q ;CN <br /> FROM THE SHELTER OR GENERATOR FOUNDATION (MINIMUM UNLESS SHOWN <br /> OTHERWISE ON DRAWING), \ l ! I, O I 0 m ¢ Q <br /> 15 PROVIDE NEW 5/8" x 10'-0' LONG COPPER CLAD STEEL (COPPER WELD) !` it O] ?� <br /> GROUND ROD AS SHOWN. PROVIDE INSPECTION SLEEVE AT GROUND ROD TO f I L I I ._ p,Z r W <br /> SHOW BOND TO EXTERIOR BURIED GROUND RING. INSTALL GROUND ROD TWO \ J , __—_ __—_---- ----- ---� �'''I�' a = W <br /> (2) FEET MINIMUM AWAY FROM BUILDING STRUCTURE. INSTALL SO THAT TOP OF , -- ---- ___—__ ---__-----_—__—_- �,r IMOUW w N En <br /> GROUND ROD IS 30' BELOW GRADE OR FROST UNE, WHICHEVER IS DEEPER. 'T C Gr <br /> EXACT LOCATION AND NUMBER OF GROUND RODS TO BE ESTABLISHED ON SITE (AND BASED ON 'FALL OF POTENTIAL GROUND RESISTANCE METHOD"FOR RESISTANCE < 5 OHMS. IDEALLY DRIVEN GROUND RODS ARE BONDED TO THE \ 1 � mi <br /> BURIED GROUND RING AT 10'-0' ON CENTER, BUT MAY BE A MINIMUM OF I AC-2 ,O ) I �Q 11J <br /> 8'-0'APART AND A MAXIMUM OF 15'-0'APART. <br /> 1B BOND GENERATOR TO HALO GROUND RING AT OPPOSITE CORNERS WITH A #2 ( > US < <br /> AWG STRANDED GREEN JACKET COPPER CONDUCTOR. x I 0 ___-------------------- 1 © , (/) <br /> 1 BOND FENCE POST TO IXIST NG BUILDING GROUND ST5ILM WITH A#2 AWG I I —1 ■ . <br /> (, n n ii. MP.) I <br /> STRANDED GREEN JACKET CONDUCTOR. f <br /> x A <br /> , ._I___ _7h.: r <br /> /r <br /> ID <br /> ili\s, III <br /> I <br /> x I C <br /> s II <br /> REV I DESCRIPTION I DATE <br /> A ISSUED FOR AI%SIJBSI:rren. 08292017 <br /> / ( '� 1 • • I y I E. -IA-- I B RE-ISSUED FOR 90%SUeNlrr00 1122201T <br /> 'sli +�•Ir I II C ISSUED FOR 100%ECS SUBMIT.-, 01 OS 2018 <br /> 0 ) 0 j133UED FOR PERMITG2.0'2010 <br /> Lk I fi� [-I <br /> I Ib. <br /> I <br /> I ' <br /> i I `1 I I <br /> O PRELIMI U(COMPLNNCESUBMnTAL3 DATE <br /> o/ • I PRELIMINARY SUBNSSIDN <br /> ^ I , I 1. ` I 30%SUSMLssgN <br /> \_},_ <br /> C. I I i___ <br /> 80V.SUBME910N <br /> __—_ �.� __ —__ IBO%SUMIS510N 11.052G1:.� __— _- 100%SUBMISSION (11.052ftE <br /> L <br /> . _ _ .}y,y}� ISSUED FORISSUE _--_ <br /> 3 ,.'l//i/i'II A ISSUED CONSTRIICnON <br /> ,vr RECORSUED D SET <br /> 02.0 201e <br /> , /' } I I I ) -la) O RECORD SET(ASBULTS) <br /> I 1 <br /> I <br /> / 1 ® PROJECT NO: STAMP r,.r <br /> ; ` \\\\V 7170182 „�+ <br /> I / X • / • <br /> ' CADDWGF7P: 'v%�''i <br /> 1 ® 1 1 = 1 © 1 DESIGNED BY: FA r- C2 2 <br /> ' 1 - - \ DRAWN BY: LP 2 , <br /> _ CHECKED BY: RL ' <br /> 4. <br /> COPYRIGHT: <br /> 2018.,•"e:'48155.-: <br /> 40 <br /> ilD <br /> GROUNDING NOTE: ®) - <br /> SHEET TITLE <br /> 1, ALL GROUNDING CONDUCTORS ABOVE GRADE SHALL BE RUN IN (III)3/4' FLEXIBLE PVC CONDUIT. CONDUIT SHALL BEGIN WITHIN MEND <br /> 3/4' OF ABOVE GROUND CONNECTION POINT, SHALL END / GROUNDING <br /> 24- BELOW GRADE MINIMUM AND SHALL BE FILLED WITH <br /> SEALANT AT ABOVE GROUND CONNECTION POINT. SECURE FLEX <br /> CONDUIT EVERY 24 INCHES WITH NON-METALLIC TIES. /-17/"... .)) NORTH PLAN <br /> 2. ALL GROUNDING SHALL ADHERE TO VERIZON STANDARD NSTD46 22.x3' E 1/2'- 1•-0• GROUNDING P LAN 1 SHEET NUMBER <br /> 11•517'SCALE: 1/4-� 1'-0• 2' 1 0' 2' E 1 30 <br />