� � o
<br /> CEILING PLAN NOTES � �
<br /> w3
<br /> 1 BI�DER IS RESPONSIBLE TO �ESIGN AND PROVIDE ALL SECONpARV SUPPORT � p
<br /> SVSTEMSTOPRIMARYSUPPORTSYSTEMSABOVEftEFERT01lA-551FORCEILING �
<br /> PERFORMANCE RE�UIREMENTS
<br /> 2g
<br /> 2. UNLESSNOTEDOTHERWISE, ALLCEILINGShREOPENTOSTRUCTUREABOVE. w
<br /> ��� '� 3. REFER TO AN� COOR�INATE WRH MECHANICAL SHEETS FOR HVAC DUCTAND � _
<br /> � � � � � 3 � � � � � � � DIFFIISER LOCATIONS. �' �
<br /> �02 � �
<br /> W 4. REFERTOANDCOORDINATEWITHELECTRICALORAWINGSFORLIGHTINGANO
<br /> ¢I ELECTRICAL INFORMATION. � '--'
<br /> = I � 5. AT SUSPENDED ACOUSTICAL CBLINGS, CENTER LIGHT FI%TlIRES DIFFl15ER5. M
<br /> , U I Q SPEAKERS. FIRE SPRINKLER HEADS, ALARMS. DETECTORS ETC. WITHIN TILES. W
<br /> '. � � Q W UNLESS NOTE� OTHERWISE � �
<br /> . � � N 6. OIMENSIONS ARE W FACE OF FINISH AND CENTERLME OF FlXTURES, UNLESS NOTED
<br /> i I 1 — OTHERWISE
<br /> 5318
<br /> 1. REFERTOA551FORTYPICALSUSPENDEDACOUSTICALCEILINGDETAILS. REGISTERE�
<br /> ARCHITECT
<br /> O� - - � � I -� - - - � O II 8. REFERALSO TO FlNISH SCHE�ULE FOR CEILING PINISHES c«r- �' _ .y.�_„_ ,
<br /> � 9. CEILING HEIGHTS ARE MEASURED FROM THE FlNISH FLOOR OF THE LEVEL INDIGATE� KENT L MCIAREN
<br /> I _ I � PLANS. STATEOFWASHINGTON
<br /> 10. PAINT ALL EXPOSED STRUCTURE, METAL DECKING, DUCTING, AND CONDUIT PER
<br /> I SPECIFICATIONS.
<br /> I CHILD TOILET a�� � ADVENTURE i t. CONTINUE ALL WALLS TO UN�ERSIDE OF METAL DECKING UNLE55 NOTED
<br /> WATGH ZONE OTHERWISE
<br /> I o ,z,B w -- o ,
<br /> 125A � ♦. ' 126A
<br /> 8 0 O � 12. ATFRAME� WALLSADJACENTTOCEILINGSTHATAREOPENTOSTRUCTUREABOVE.
<br /> I CONTINIIE GVPSUM BOARO ANO FlNISH TO STRUCTURE ABOVE ON BOTH FHCES.
<br /> � TOILET � REFER TO SHEET A-631 AN� FOft TYPICAL �ETAILS AT DECK ABOVE.
<br /> � �
<br /> °1 � i, 12fiB 13. CENTER SUSPENDED CEILING GRIDS WITHIN OVERALL DIMENSION OF CEILING
<br /> I �i � . .. -� .. � � � --� . . i SVSTEM PER GRAPHIC REPRESENTATION ANO PROVIDE EQUAL DIMENSIONS AT
<br /> � '
<br /> a� e' - 0" - - EDGE OF OUTMOST WALLS AN�/OR SOFFITS, UNLESS NOTED OTHERWISE.
<br /> � q I — _ _ �^` 14. PROVI�E AftMSTRONG BERC2 CIIP (OR APPROVE� EQUNALENT) IN LIEU OF 2"
<br /> I q 301 - — - - — - - — - �— - - — - - - - — - - — - - T - q 301 PERIMETER HNGLE PER ICC 35R-1308
<br /> � 3'-6" � E� EQ 3'-P' 15. ONWALLSTHAT �ONOTCONTINUETOUN�ERSIDEOFDECN, STOPWALL56"ABOVE
<br /> � I � � � � � � � -- -- �' HIGHEST ADJACENT CEILING. PftOVIDE TOP OF WALL BRACING PER STRUCTURAL.
<br /> O ��' II - - _- a10 0 CHECK-IN
<br /> B _ �L.l O
<br /> _ _ y �� � ,2�, .� .
<br /> ° ' ss < s B
<br /> I I � CIRCU BTION— � f �� -� A.551 . _ . :_ LOB Y �� - 5.
<br /> � � ' I � �� ' - ° -��' �� � � � • � � � - - � CEILWGPLANSHEETNOTES
<br /> I. �ea ea he� o.� I � io n s
<br /> �' V RCP-Oi VERIFV ALL LIGMTING PER ELECTRiCAL
<br /> . � .. - I I " � � ' j OFFICE EXEWTIV� 9� �. � � . '� TdLET. ' \ .
<br /> � MGR . � _�IREC�OR ' � _ I� � �i� � � I �� :C � • RCR02 EKY�IGHT. REFERTOA-06�
<br /> ' s � 123 � i.. . r . . . . _ 4 2 - m .-
<br /> STAIRB� � o ALCOVE �I _pI � � � o RCP-03 CONFIRMALLDUCTLOCATIONSPERMECHANICAL Qt
<br /> li 9:_����� ��]
<br /> � � . , . .. �8. ��� I� 9 6 - �� - � .
<br /> _ � �
<br /> � I_ �. 9 0 . �., TELH i� TEA�CR'IENN � RCP04'� -� � C NFE09 NCE Is� o ftCP-OG RANGEHOOD, PERMECHANICAL
<br /> i /
<br /> � �, 52 ' � . _.__ . i 118 I .. 111 � . . . �� _ .., - _ o� ..°
<br /> I . . � � I 9 a� �' ' I II � � - RCP-OS TRX MOUNTEO TO UN�ER SI�E OF STRUCTURE
<br /> i . - _ i - i. , _ �9 O __ � --��___ . -. StORAGE _ " . 1- -i___. .. � ��, -. ,. -_
<br /> A-551
<br /> � I RR�a� �, � � � `- � �HnReo . . . -- _ . � he -°"� . � CEILING PLAN LEGEND
<br /> , I qqEq IOFFICE p . � . _
<br /> , �yp ' 118 �'. � . . i , - � i . FCT-0 ACOUSTIC CEILING TRE
<br /> � . _ __ _ _ � � � .. ' � (Tx0')
<br /> ^ �II � �9 -fi" . I � �� SUbPORT , � INTERGENERATIONAL � F13x I � COMMUNITYI A-551 m I � � ^ - �
<br /> � � _ _ _ _ _ _ --- � _ 121 _ _ _ _ _ ty4 i MULTIPURPOSE � 3
<br /> ' — -� - —' - - — _ - - I _ - - � _ . � � ACR2 AGOUSTIG GEILING GLOUD (2'aE')
<br /> - — I.. - - � � - — _ -
<br /> A301 �� �9 p�,. � i. . � i. � . ... I ��� � � ��Z _. I ' SEATMG � � -6� A-301 SUSPENpEDFROMSTRUCNREABOVE
<br /> . - - 1_ � ,� 10] — .
<br /> . , , � -DIRECTOR STORA E , I � RCP-03 � ��� I � CEMENTPLASTER �PLSTR)
<br /> ' .,_ _ . __ . _� . . ,. �_'i - �.�
<br /> � � _ � " t22 9 0 ��9 RCP-03 . � . . . �
<br /> .. STORAGE ' - - . . _ .
<br /> � I
<br /> _
<br /> � ! 1za � - � '� - � � � � . � ACOUSTIG GEILING PANEL (ACP4IACP-2) 4'X4'AND
<br /> . __- _ _ ` � �� .
<br /> i . . , I . . � �9 9 . �I � 4X8' - SUSPENDE� FROMSTRUGTURE
<br /> ♦ �'' .. O . 9' - 0.� _.- - _. . . , � -.
<br /> - _'
<br /> � . W � � � � � - . � � � ' � I � - � D ._ GYPSUM WALLBOAR� CEILING (GWB)
<br /> O M , , S , , Eo , Eo ;, O
<br /> I LORRIOOR A 551 � q � OVER METAL FRAMING @ i6"OC. REFER TO STRUCTURAL
<br /> 5� �.. � � 2' 3 12� . �. 2�� � . � 134 I� � . / 5 6� . I
<br /> t0 � 0
<br /> � - � A-551 ` RGP-03 ' "-�' �� . � � EXPWED TO UNDERSIDE OF STRUCTURE (EXP)
<br /> � � I I
<br /> � I . . . . . . . . .. . . . ' , � �
<br /> � � A551 _�_ � PHENOLIC PANEL
<br /> � . _ . . . . WORK . .
<br /> I _ A�MIN g. �" ROOM IT
<br /> � 135 � 138 c�. � � FIBER CEMENT PANEL AT SOFFIT, WLOR FC 1
<br /> � 2 � — — _. _— '— ___. — .— 13] �. , I —_ - _ � - "
<br /> A-301 � — — — — — — — � — — — — — — — — — — — — — — — .— . — . ._�' _. , —. �—. � TORAGE — —� '�. � _� — — -� �I� � LIGHt REFEftTOE�EC �
<br /> �A301`
<br /> .A-551 �� LIGHT. REFER TO ELEC �c
<br /> I . . , . . .. . , . _ ... 136 ' . . - . .— . G
<br /> � � GYMNASIUM STORAGE i��� I , I LIGHT, REFER TO ELEC }
<br /> \
<br /> , � ��Q 133 � . . � � �ti LIGHT, REFER TO ELEC �
<br /> I '`�° . ° J
<br /> �y� (� LIGHT. REFERWELEG C
<br /> � I G
<br /> _oni m
<br /> � E%O \ q-551 r l LIGHT, REFER TO ELEC Q
<br /> RCISE
<br /> RCP 03 p RCP-03 � �❑
<br /> u..
<br /> I / ��� , V (� EXITLIGHT, REFERTOELEC L
<br /> �. �.�; ,3, r W
<br /> I ��._ o�. ii. o _ .-ir_ or, � F" >
<br /> � � _ _ � _ _ EQ �'__ 6 � fi'�0"—� � C MECH GRIL�, REFER TO MECH � a Q
<br /> - - - - - — - - - - - - - - - - - - - - - - T �T �_�° - - - - - I - - — � 1 J � m3
<br /> �oanc
<br /> �� 163 � fi'-�' �� Ep � � MECH GRILL REFER TO MECH U Q �
<br /> U
<br /> A-301 _ - � - — - . . .- .. . . � A301 � �\ p W p
<br /> 10'-0" � FAN, REPER TO MEGH O / M N
<br /> . . � . . � w r > m
<br /> � I _ _ _ - � . � a vwrn
<br /> . I . , � . � I ' � >> '� CEILING HEIGHT
<br /> o I � � � � � � RCP-0S- RCP-06 .A_� .��a o � B ACOIISTICBAFFLES (AC). Cl1STOMS2E24"%8]2" � IssueforConstruqron OBDZ2010
<br /> � � ' . . ' I —a I,
<br /> I ' � �
<br /> O , - _ — _ — - _ _ � - -- �
<br /> A-551 � OfiO�20te
<br /> � ��� acuxo
<br /> � � ovEaHEno KEY PLAN iaz<s
<br /> n
<br /> � DOOR, NAL � (I] I �"��e .
<br /> � WHENOPEN � �
<br /> sxeen..e
<br /> U w FIRST FLOOR CEILING
<br /> Q I � i PLAN - WEST
<br /> O 1 .5 O �\oz O O O � I O ' i
<br /> PLAN
<br /> NORTH
<br /> � - '- SCALE�1/e"= 1�'-0" �B � BCRA �
<br /> EFLE TED CEILING PLAN - WEST __ i
<br /> ve� — i a �—
<br /> � ���,� �o,s_�, ��.�a�.rsaaE��
<br /> , ��E..
<br /> PWN
<br /> NORTH
<br /> � � A- 151A
<br /> �Ss�E FOR
<br /> IfSNEETMEASURESLESSiHAN)OXOP[ITISAREOUCEOPRINTREDUCESCALEACCORDINGLV CONSTRUCTION