Laserfiche WebLink
s <br /> U nE <br /> - (3 DI <br /> 4- _ <br /> Ulv <br /> .� o E <br /> U � <br /> ,,; 1 6-0'UPPER FL PLATE HEIGHT kn- 6 0 <br /> m a <br /> Ai IAX <br /> II 1 1 Ln <br /> Z <br /> 1/4'WEB STIFFENER <br /> EACH SIDE OF WEB 4x ry� <br /> LEACHE STIFWEB W 16x40 W `•' <br /> ! O <br /> 01 <br /> W 10 x26 3/16"FILLET.L=2", I,, <br /> 3/16"FILLET,L-2", (6)REQ'D EACH SIDE W t6 z 40 <br /> (6)RED D EACH SIDE <br /> OF WEB FLOOR SHEATHING O ` 61 <br /> 2" W10x26 Q <br /> dir --.1 <br /> OF WEBI 3z_FILLER EACH SIDE OF WEB I L '_ _ <br /> 3/16"FILLET,L=2", -I- <br /> V j /^t`` N -I- <br /> km <br /> \��1/2"x 53/4'x 7.PLATE �-1/2'x7'x7'PLATE (8)REO'CI EACH SIDE—r lJ. W O <br /> 3/16"FILLET ALL \ 3/16"FILLET ALL \ <br /> N S <br /> AROUND 5/8"0 x THRU BOLTS AROUND 5/8'0 z THRU BOLTS OF WEB 1!4"WEB = ++- kn 6 <br /> \—EACH SIDE OF WEBEACH SIDE OF WEB \ STIFFENERS EACH <br /> - (2)TOTAL REQ'D (2)TOTAL REQ'D SIDE OF WEB 2 x 10 EXISTING FLOOR JOISTS i_ O <br /> 3'x 3'x 1/4"STEEL \-3'x 3'x 1/4'STEEL (2)7/8'0 THRU \ W/LUS28 HANGERS �'[ <br /> TUBE TUBE BOLTS ,—5/8"0 THRU BOLTS @ 16"O.C. V <br /> - m w <br /> DETAIL S1 DETAIL S2 DETAIL S3 DETAIL S4tv <br /> Not To Scale Not To Scale Not To Scale Not To Scale _ W <br /> _' EXISTING <br /> - UPPER R.SUB-FLOOR <br /> 2 EXISTING <br /> ,`` I MAIN FL.PLATE HEIGHT <br /> n� i7T <br /> ...EXSTING DBL 2X10 RIM JOIST ii f <br /> E 2X10 FLOOR FRAMING 4--.!! <br /> I-; Z <br /> VIII <br /> O <br /> EXISTING <br /> I- FOUNDATION Z U <br /> 3 x 3x 1/4 STEEL TUBE I N l <br /> 5/8"0 ALL-THREAD W/ , 111 �~ w ( <br /> FLOOR SHEATHING TOP&BOTTOM NUT <br /> 4C13- <br /> 4 x FILLER EACH SIDE OF WEB EPDXY GROUT W/ 4 <br /> 3/16"FILLET ALL SIMPSON SET-XP w - -7�I I IZ - a *4 CONT.EACH WAY 1 <br /> AROUND EPDXY g <br /> 1/2'x 312'x9"PLATE -a. <br /> 2 z 10 EXISTING FLOOR JOISTS a•" SOLID GROUT AFTER a a n PER PLAN t_- <br /> w LEVEL S - I <br /> W/LUS28 HANGERS Id ®I a t....- " - .. -3'CLEAR S I'C_ '✓C1 F/''*_ tl_A I Fn 2RR r..An�^FEI E 1WI I MHO <br /> `�(2)ROWS OF 5/8'0 THRU ' W - WIDTH PER PLAN -I (2)LAYERS OF 3/4'SUBFLOOR OVER = SONG OVER LU <br /> BOLTS @ 16"O.C. ✓ Z 2/06 JOISTS 0910 O.0 OVER - STRUCTURAL SHEATHING ClEXISTING SUBLOOR OVER \ _ 216 STUDS @ 16'O.0 WITH <br /> EXISTING 2%10 FLOOR FRAMING WITH RBERGLASS BIB INSULATION R-21 <br /> DETAIL S5 DETAIL S6 DETAIL S7-ISOLATED SPREAD FOOTING DETAIL EXSTINGINSULATION \ OVER vrSWB <br /> Not To Scale Not To Scale Not To Scale ` ' <br /> yEXISTING .. <br /> MAIN FL SUB-FLOOR f, <br /> -� _.. EXISTING \ <br /> • W <br /> + Z <br /> FAMILY RM SUB-FLOOR ,^� <br /> VI <br /> WELLER CONSULTING ENGINEERS,P.C. II <br /> I it (9 <br /> 219258THPLW 1 I=E N <br /> BOTHELL,WA 95021 ` I l 1ti <br /> (425)455-9568 • <br /> I <br /> ENGINEER REVIEW I <br /> THIS DRAWING HAS BEEN REVIEWED PRA1.1' DIM <br /> PER THE ATTACHED CALCULATIONS = EXISTING FOUNDATION KG 10/1/2018 <br /> i I <br /> PREPARED BY WELLER CONSULTING ENGINEERS,P.C. IF I I=- - ehFUB1 OAT E:C <br /> //� - -!_ NEW FOATING/AB 0 w,vasxuel na <br /> BY: f/ `-- _ _-.. . I. I,'-_'__- PER DETAILL57/P3 Z re: <br /> - --_. — (WHERE SHOWN ON PLAN) Z <br /> \ <br /> JOB: 18 013 J DATE: 10/2./le, -—WIDTH PER PLAN n,vncnn.MI. ' <br /> ' ucvrsnnnl.DAM:L <br /> - WALL SECTION SHEET <br /> A <br /> O Scale:3/4'=1'-(7 A3 <br /> 6;75) <br />