Laserfiche WebLink
REMOVE & REPLACE FAN & CONTROLS <br />W/ 1 <br />LEGENDEW <br />(N) PANANSONIC WHISPERGREEN <br />WHOLE HOUSE FAN ON MOTION <br />2, (E) EXISTING <br />SENSOR & FAN SPEED CONTROL <br />3, EXISTING 2X4 WALL= <br />MODULE <br />4, NEW 2X4 WALL <br />FAN DUCTED TO EXTERIOR <br />5. NEW 2X8 WALL - � <br />5, DEMO WALL = E := <br />REMOVE & REPLACE FAN AND <br />7, (N) HARDWREDIRED �N <br />CONTROLS WITH <br />(N) PANANSONIC WHISPERGREEN <br />CO DETWIRE <br />�, (�) HARDD WIRED s <br />�N <br />ON MOTION SENSOR & CUFF DELAY <br />SMOKE DETECTOR W <br />(N) LOW STEP ADA <br />TIMER <br />SHOWER <br />FAN DUCTED TO EXTERIOR <br />(N) SLOPED <br />E ITH <br />THRESHOLDS <br />CURTAIN ROD. ALL BEDROOMS, LAUNDRY & <br />HALLWAY <br />1, SEE DEVELOPMENT SCOPE OF <br />WORK FOR COMPREHENSIVE <br />(N) ENERGY STAR <br />I ► <br />► <br />LIST OF WORK, <br />RANGE HOOD <br />► <br />► <br />""� <br />aUn <br />2, PREPARE, PRIME AND PAINT <br />AT (E) LOCATION <br />i <br />ALL INTERIOR CEILINGS, WALLS <br />AND TRIM, SHEEN - SATIN FOR <br />0► Q <br />' <br />TYPICAL WALLS AND <br />SEMI GLQ S FOR TRIM ANDCEILIN <br />N <br />-(E).Bedr00m 4 (E) Bedroom 3 <br />BATHROOM WALLS AND <br />itchen (E) Dining Room <br />B 11. <br />CEILINGS <br />S <br />ON <br />3, BATHROOM FLOORING. (N) <br />El <br />FIBERGLASS LAMINATED SHEET <br />E Garage <br />VINYL FLOORING <br />r—(E) ELEC PANEL <br />- — 0 <br />4, VERIFY THAT FANS AT <br />r <br />' 0 I <br />LAUNDRY AND BATH ARE <br />---------- _ _ _ _ _ , <br />i <br />(N) CORNER GUARDS <br />I <br />N — — <br />DVCTED TO THE EXTERIOR, <br />REPLACE GLAZING ' ' <br />N <br />�,r��✓-w�-v� <br />5, REMOVE IN WALL HEATERS AT <br />EACH SPACE REPLACE <br />WITH (N) DOUBLE <br />N <br />AND <br />WITH NEW WALL HEATER. SEE <br />GLAZIN <br />0 <br />SCOPE OF WORK <br />(E) Living Room <br />(E) Bedroom 1 (E) Bedroom 2 <br />0 <br />(N) LED LIGHT FIXTURE IN (E) <br />LOCATION- TYPICAL <br />AT ALL ROOMS (EXCEPT DINING)— <br />(N) LED LIGHT FIXTURE IN (E) <br />LOCATION- TYPICAL <br />AT EXTERIOR LOCATIONS — <br />First Floor Plan <br />Scale: 3/16" = V-0" <br />(N) INSULATED <br />FIBERGLASS DOOR <br />AND WOOD FRAME <br />ADA THRESHOLD <br />GROSS AREA; <br />1,248 S.F. <br />2I1VIrOrirr�E ntai <br />WORK$ <br />Community Design Center <br />40215th Avenue Fast <br />Seattle, Washington 98112 <br />206.329.8300 <br />206.329.5494 fax <br />House Renovations <br />$608 Cady Road <br />Everett, WA <br />31 January 2020 <br />Rev.1. 25 Febrwary 2020 <br />Proj. No.19.049A <br />A2.1 <br />2I3 <br />