Drew Martin <br />From: Drew Martin <br />Sent: Tuesday, September 3, 2019 10:12 AM <br />To: 'devin@bnharch.com' <br />Subject: City of Everett Permit Services: 1321 Colby Avenue (131908-012) - First Building Review <br />Devi n, <br />This email follows our conversation regarding this project. The drawings generally appear good. I have a few questions <br />that I need you to address to complete the review. If needed, please update the drawings. <br />1. The area appears to have at least one accessible restroom directly off the waiting room. The adjacent restroom <br />appears to be just under the 5' turning circle, and it is not clear if the restroom at the south end is intended for <br />the general public. The project should satisfy the requirements for accessibility improvements per IEBC Section <br />705.2. Potential improvements to this area including adding signage for the accessible restroom(s), pipe <br />protection at the sinks, vertical grab bars, and flush control located on the open side. Other things such as the <br />existing (i.e., depicted) horizontal grab bars having correct size and position, toilet seat having the correct <br />height, and the clearance around the toilet (depicted, but not dimensioned) should be verified. Please provide a <br />statement addressing accessibility deficiencies, and improvements as needed to satisfy Section 705.2. See IEBC <br />Chapter 8. <br />The new partition walls should have top and bottom connections to provide out -of -plane restraint satisfying IBC <br />Section 1607.14. It is understood that the new wall at Room 212 is intended to connect at the top to and <br />existing soffit that supported a sliding door. The construction of this soffit (and its ability to provide the lateral <br />support) are not clear. In addition, this condition, which is understood to be depicted in Section 1/A9.0, only <br />occurs at Room 212. All other locations with new wall did not previously have the sliding doors, such as the wall <br />where Section 1/A9.0 is referenced on Plan 1/A1.0 and noted as "TYP". The details for the walls, and their top <br />and bottom supports, should be reviewed and revised as needed. The connection requirements (e.g., fastener <br />size and spacing, top of wall bracing, etc.) should be specified in the details. <br />3. The center of the work area on Plan a/A1.0 includes two new walls in a "T" configuration. One wall is specified <br />as both Type A and Al, which appears intentional. The other wall dividing Hall 204 from Hall 207 does not <br />specify a type. It is presumed that Al is intended to provide sound insulation. Please verify and revise the plan as <br />needed. See IBC Section 107.2.1. <br />Please let me know if you have questions. Thank you. <br />_ Drew Martin, P.E., S.E. <br />Associate Engineer —Commercial Plans Examiner I Permit Services <br />425.257.8813 13200 Cedar Street, 2nd Floor, Everett, WA 98201 <br />EVERETT Hours: Monday — Friday 7:30am-12:OOpm and 1:OOpm-4:OOpm <br />everettwa.gov I Facebook I Twitter <br />Note: Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br />Records Act. <br />