Laserfiche WebLink
TELECOMMUNICATIONS WIRING COMPONENTS <br />(COAXIAL ANTENNA CABLE) <br />1. GENERAL <br />A. ALL MATERIALS, PRODUCTS OR PROCEDURES INCORPORATED INTO <br />WORK SHALL BE NEW AND OF STANDARD COMMERCIAL QUALITY. <br />B. CERTAIN MATERIALS AND PRODUCTS WILL BE SUPPLIED BY THE OWNER (REFER <br />TO GENERAL CONDITIONS FOR THE LIST OF OWNER FURNISHED EQUIPMENT, <br />MATERIALS AND SUPPLIES FOR THESE ITEMS). THE CONTRACTOR IS RESPONSIBLE <br />FOR PICKUP AND DELIVERY OF ALL SUCH MATERIALS <br />C. ALL OTHER MATERIALS AND PRODUCTS SPECIFIED IN THE CONTRACT <br />DOCUMENTS SHALL BE SUPPLIED BY THE CONTRACTOR. <br />2. MATERIALS: <br />A. COAXIAL CABLE: <br />1. INSTALL COAXIAL CABLE AND TERMINATIONS BETWEEN ANTENNAS <br />AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS <br />WITH COAXIAL CABLES SUPPORTED AT NO MORE THAN T-0" O.C. <br />WEATHERPROOF ALL CONNECTORS BETWEEN THE ANTENNA AND <br />EQUIPMENT PER MANUFACTURERS' REQUIREMENTS. TERMINATE <br />ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF EQUIPMENT <br />LOCATION UNLESS OTHERWISE STATED. <br />2. ALL COAX RUN LENGTHS GREATER THAN 143 FEET SHALL BE 1-5/8" <br />AND IN LENGTH LESS THAN OR EQUAL TO 143 FEET SHALL BE 7/8". <br />3. ANTENNA AND COAXIAL CABLE GROUNDING <br />A. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON <br />STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS) <br />4. COAXIAL CABLE IDENTIFICATION <br />A. TO PROVIDE EASY IDENTIFICATION AND UNIFORM MARKING OF <br />ANTENNA CABLING, PLASTIC TAGS SHALL BE USED AT THE <br />FOLLOWING LOCATIONS: <br />1. FIRST LOCATION IS AT THE END OF THE COAX NEAREST <br />THE ANTENNA (WHERE THE COAXIAL CABLE AND JUMPER <br />ARE CONNECTED). <br />2. SECOND LOCATION IS INSIDE THE EQUIPMENT SHELTER <br />NEAR THE WAVEGUIDE ENTRY PORT. <br />B. USE ANDREW CABLE TIES (PTA 27290) TO SECURE IDENTIFICATION TAGS. <br />5. TESTING <br />T-MOBILE SHALL PROVIDE AN INDEPENDENT TESTING AGENCY TO PERFORM THE COAXIAL <br />SWEEP TEST & REPORT. THE CONTRACTOR IS TO PROVIDE CLIMBER / QUALIFIED <br />PERSONNEL TO ASSIST IN ANY REPAIRS AND WEATHERPROOFING ONCE THE TEST IS <br />COMPLETE. THE CONTRACTOR IS TO PROVIDE T-MOBILE A MINIMIM OF 48 HOURS NOTICE <br />PRIOR TO THE TIME OF THE SWEEP TEST. <br />ELECTRICAL NOTES: <br />INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED IN <br />COMPLIANCE WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE LAWS, RULES AND <br />REGULATIONS FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH <br />SPECIFICATIONS PER A.S.T.M. 8 231, B 400, I.C.EA. S651-401, I.C.EA. P81-670, & LOCAL PUD. <br />PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER <br />FURNISHED BACK BOARD. <br />UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE 1, <br />CONFORMING TO UL ARTICLE 651: WESTERN PLASTICS OR CARLON MANUFACTURER. COUPLINGS <br />SHALL BE SLIP-ON, SOLVENT SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC <br />DUCT. ALL BENDS SHALL BE "WIDE SWEEP" TYPE WITH A 24" MINIMUM RADIUS. ALL CONDUIT <br />UNDER ROADS SHALL BE RGS, (OR PVC ENCASED IN 8"x18" RED CONCRETE DUCTBANK). <br />CONDUIT USED INDOORS SHALL BE E.M.T., AND RIGID GALVANIZED STEEL FOR OUTDOORS. <br />COUPLINGS SHALL BE RIGID STEEL AND COMPRESSION TYPE FOR E.M.T. SET SCREW FITTINGS <br />ARE NOT PERMITTED. FOR ALL STUBS -UPS, USE RIGID GALVANIZED STEEL CONDUIT. <br />WIRE AND CABLE SHALL BE OF THE TYPE AND SIZE AS REQUIRED BY NEC. THERE WILL BE NO <br />SPLICES ALLOWED. <br />PROVIDE HDPE PULLING HAND HOLES AS NEEDED. <br />CONTRACTOR SHALL PROVIDE TEST OF THE GROUNDING SYSTEM BY CERTIFIED TESTING <br />AGENT. PROVIDE INDEPENDENT TEST RESULTS TO THE PROJECT MANAGER FOR REVIEW. <br />GROUNDING SYSTEM RESISTANCE TO GROUND SHALL NOT EXCEED 5 OHMS. ALL ABOVE GRADE <br />INTERIOR GROUNDING CONNECTORS SHALL BE DOUBLE -LUG COMPRESSION TYPE. ALL BELOW <br />GRADE AND EXPOSED EXTERIOR GROUNDING CONNECTIONS TO PERMANENT EQUIPMENT AND <br />FIXED BUILDING ELEMENTS SHALL BE CADWELD TYPE. CARE SHALL BE TAKEN TO REVIEW <br />CONNECTION LOCATIONS AND MATERIAL TYPES TO AVOID POSSIBLE GALVANIC CORROSION. <br />ALL EXPOSED GROUNDING CONNECTIONS TO BE COATED WITH ANTI -CORROSIVE AGENT SUCH <br />AS "NO-OXY", "NOAOLX" OR "PENETROX". VERIFY PRODUCT WITH PROJECT MANAGER. ALL <br />BOLTS, WASHERS AND NUTS USED ON GROUNDING CONNECTIONS SHALL BE STAINLESS STEEL. <br />ALL EXTERIOR GROUND BARS SHALL BE COATED WITH ANTI -CORROSIVE AGENT SUCH AS LPS-3 <br />OR AS PER NOTE 6 ABOVE. <br />1 GENERAL NOTES <br />ELECTRICAL NOTES (CONTINUED): <br />INSTALLATION OF SECONDARY POWER AND CONNECTION TO METER SHALL BE COMPLETED IN <br />COMPLIANCE WITH NATIONAL ELECTRIC CODE, NFPA 70, AND THE STATE LAWS, RULES AND <br />REGULATIONS FOR INSTALLING ELECTRIC WIRES & EQUIPMENT, ALL LATEST ISSUE, AND WITH <br />SPECIFICATIONS PER A.S.T.M. B 231, B 400, I.C.EA. S651-401, I.C.EA. P81.570, & LOCAL PUD. <br />PROVIDE A METER BASE PER LOCAL UTILITY STANDARDS. MOUNT ON SIDE OF OWNER FURNISHED <br />BACK BOARD. <br />ALL JUNCTION AND OUTLET BOXES TO BE LABELED WITH KROY TAPE, OR EQUAL, DESIGNATING ALL <br />CIRCUIT NUMBERS CONTAINED IN EACH BOX. <br />CONTRACTOR TO ENSURE ILC PROVIDED WITH (2) INTERNAL TVSS. <br />CONTRACTOR SHALL COORDINATE WITH SITE SURVEY TO LOCATE EXISTING UNDERGROUND UTILITIES <br />WHEREVER POTENTIAL CONFLICTS/ INTERFERENCES EXIST, HAND EXCAVATE TO AVOID DAMAGE. <br />CONTACT ALL UTILITIES TO LOCATE UNDERGROUND PIPING IN PUBLIC ROW. <br />VERIFY THAT A.I.C. OF THE UTILITY DOES NOT EXCEED THE A.I.C. RATING OF THE PROVIDED <br />EQUIPMENT SHELTER PACKAGE. IF OVER 10KAIC, PROVIDE FUSIBLE SERVICE ENTRANCE SWITCH AND <br />CONFIRM LOWERING OF AIC TO ACCEPTABLE LEVELS. <br />UTILITY POINTS OF SERVICE AND WORK / MATERIALS SHOWN ARE BASED UPON PRELIMINARY <br />INFORMATION PROVIDED BY THE UTILITY COMPANIES AND ARE FOR BID PURPOSES ONLY. <br />CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK / MATERIALS <br />REQUIREMENTS AND CONSTRUCT TO UTILITY COMPANY ENGINEERING PLANS AND SPECIFICATIONS <br />ONLY. CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT, PULL ROPES, CABLES, PULL BOXES, <br />CONCRETE ENCASEMENT OF CONDUIT (IF REQUIRED), TRANSFORMER PAD, BARRIERS, POLE RISERS, <br />TRENCHING, BACKFILL, PAY ALL UTILITY COMPANY FEES AND INCLUDE ALL REQUIREMENTS IN SCOPE <br />OF WORK. <br />GROUNDING NOTES: <br />1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE DESIGN AND <br />CONSTRUCTION SPECIFICATIONS AND ALL APPLICABLE LOCAL CODES. <br />2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS <br />TO EQUIPMENT IS NOT BLOCKED. <br />3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND <br />UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE <br />GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT. <br />4. ALL GROUND CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC (CADWELD). <br />5. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR & EXTERIOR) SHALL BE FORMED USING <br />TWO (2) HIGH PRESS CRIMPS. <br />6. ALL EXOTHERMIC CONNECTIONS TO THE GROUND RODS SHALL START AT THE TOP & HAVE A <br />VERTICAL SEPARATION OF 6" FOR EVERY ADDITIONAL CONNECTION. <br />7. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT <br />MATERIAL. <br />8. ALL EXTERIOR GROUND CONDUCTORS SHALL BE #2 AWG TIN PLATED COPPER UNLESS <br />OTHERWISE INDICATED. <br />9. GROUND RODS SHALL BE STAINLESS STEEL OR COPPER CLAD STEEL, 5/8"- 10-FT. LONG (OR <br />NOTED OTHERWISE ON PLANS), AND SHALL BE DRIVEN VERTICALLY WITH THEIR TOPS 18" BELOW <br />FINAL GRADE OR 6" BELOW FROST LINE FOR MAXIMUM DEPTH. <br />10. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED. BACK TO BACK <br />CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BUS ARE PERMITTED. <br />11. USE OF 90" BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' <br />BENDS CAN BE ADEQUATELY SUPPORTED. <br />12. GROUND RING SHALL BE LOCATED A MINIMUM OF 24" BELOW GRADE OR 6" MINIMUM BELOW THE <br />FROST LINE. <br />13. INSTALL GROUND CONDUCTORS AND GROUND ROD MINIMUM OF V-0" FROM EQUIPMENT <br />CONCRETE PAD, SPREAD FOOTING, OR FENCE. <br />14. EXOTHERMIC WELD GROUND CONNECTION TO FENCE POST: TREAT WITH A COLD GALVANIZED <br />SPRAY. <br />16. OBSERVE N.E.C. AND LOCAL UTILITY REQUIREMENTS FOR ELECTRICAL SERVICE GROUNDING <br />16. GROUNDING ATTACHMENT TO TOWER SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS <br />OR AT GROUNDING POINTS PROVIDED (2 MINIMUM) <br />17. MAXIMUM RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED 5 OHMS. <br />18. CONTRACTOR TO VERIFY CURRENT GROUNDING STANDARDS PRIOR TO CONSTRUCTION. <br />®■ <br />1^4 <br />z�- <br />Y' <br />Y0 <br />Lu <br />uj <br />U <br />J <br />■ <br />zul <br />rm <br />0 <br />■ <br />■ <br />11LYNX <br />1133 184TH STREET SW <br />SUITE 202 <br />LYNNWOOD. WA 98087 <br />OFFICE: (425) 778-3800 <br />JAYIPNEWWAVEARCH.COU <br />DATE, 8-21-20 <br />PREPARED BY- YML <br />APPROVED BY- JYS <br />SUBMITTALS <br />NO <br />DATE <br />DESCRIPTION <br />8-21-201 <br />FINAL PERMIT <br />8-12-20 <br />1 REVISED PERMR <br />S 11-20 <br />1 REVISED PERMIT <br />730-20 <br />1 PRELIMINARY PERMIT <br />7687 REGISTERED <br />R HITECT <br />8-21-2020 <br />JAY Y. O <br />STA OF WASHNOTON <br />SE01514A <br />CIVIC AUDITORIUM <br />DT/COLBY <br />(ANCHOR) <br />2301 COLBY AVENUE, <br />EVERETT, WA 98201 <br />SHEET TITLE <br />GENERAL NOTES <br />SHEET NUMBER <br />SP-2 <br />3�\5 <br />